HINKLEY 2560 Alford Place Tall Wall Mount Lantern Instruction Manual

June 13, 2024
HINKLEY

HINKLEY 2560 Alford Place Tall Wall Mount Lantern

HINKLEY-2560-Alford-Place-Tall-Wall-Mount-Lantern-
product

Product Information

  • Brand: HINKLEY
  • Item Numbers: 2560, 2564, 2565, 2568, 25658
  • Date of Manual: 01.01.17

Product Usage Instructions

  1. Find a clear area in which you can work.
  2. Unpack the fixture and glass from the carton.
  3. Carefully review the instructions prior to assembly.

Mounting Instructions:

  1. Prepare the mounting strap (A) by threading the two long mounting screws (B) into the back of the universal strap – see Drawing 1.
  2. Attach the mounting strap (A) to the junction box (J) using two screws (C). (not provided)
  3. To mount the fixture, slip the two mounting screws (B) through the two mounting holes (D) in the backplate (E) – see Drawing 1.
  4. While holding the fixture in place, thread the two ball knobs (F) onto the end of the mounting screws (B) and tighten.

Electrical Connection Instructions:

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

  1. Make electrical connections from the supply wire to the fixture lead wires. Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections.
  2. Refer back to this sheet to complete the installation of this fixture.

Bulb Installation Instructions:

  1. To access sockets and install bulbs, first remove the two screws (S) from underneath the roof edge (R). NOTE: After screws are removed, the bottom half of the cage (G) will drop off of thefixture.
  2. Install bulbs and replace the cage bottom half using the screws (S) removed earlier.

Glass Replacement Instructions:

  1. Find a clear area in which you can work.
  2. Unpack the fixture and glass from the carton.
  3. Carefully review the instructions prior to assembly.

Note: For further assistance or information, please visit hinkley.com.

Assembly Instructions

Start here

  1. Find a clear area in which you can work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly.
  • Prepare mounting strap (A) by threading the two long mounting screws (B) into the back of the universal strap – see Drawing 1.
    • Be sure the holes into which the screws are threaded match the spacing of holes (D) in the back plate (E).
  • Attach mounting strap (A) to junction box (J) using two screws (C). (not provided)

SAFETY WARNING : READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections. Then refer back to this sheet to complete installation of this fixture

  1. To mount fixture, slip the two mounting screws (B) through the two mounting holes (D) in the backplate (E) – see Drawing 1.
  2. While holding fixture in place, thread the two ball knobs (F) on to the end of the mounting screws (B), and tighten.
  • Top access sockets to install bulbs, first remove the two screws (S) from underneath the roof edge (R). NOTE: after screws are removed the bottom half of the cage (G) will drop off of the fixture.
  • Install bulbs and replace cage bottom half using the screws (S) removed earlier.

Glass Replacement

start here

  1. Find a clear area in which you can work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly.
  • If glass in top of fixture needs replacing first remove the bottom half of the cage or top roof depending on your particular fixture instructions.
  • Next remove screw (1) which holds the glass clip (2) in place – see Drawing 1.
  • Next remove glass panel (3) along with silicone gasket that is between the glass panel and the cage roof.
  • Remove gasket and place on new piece of glass. Slip glass into cage roof, making sure the top edge is behind tab (T) in roof.
  • Lay glass into roof, making sure to center it.
  • Now replace glass clips (2) and secure with screws (1) removed earlier.
  • Now replace bottom of cage per your fixture instructions.
  1. If glass in bottom of the luminaire cage needs replacing first remove the votre luminaire. top of the cage per you fixture instructions.
  2. Next remove the four screws (S) in the four corners of the bottom cage top casing (P). Lift casting off of bottom cage (C) – see Drawing 2.
  3. Now bend glass clips (C) up so glass panel (G) can be removed. Lift panel out of bottom cage by aligning glass panel with notched (N) in metal top band (M) of bottom cage.
  4. Slip new glass panel into bottom cage, bend glass clips over to secure glass in cage.
  5. Now replace top casting onto cage removed earlier and secure with screws.
  6. Assemble cage to roof following your fixture instructions.

Wiring grounding instructions

SAFETY WARNING : READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS

Indoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Please refer to the grounding instructions below to complete all electrical connections

Outdoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Cover open end of connectors with silicone sealant to form a watertight seal.
  4. If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
  5. Please refer to the grounding instructions below to complete all electrical connections.

Grounding instructions

Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) – see Drawing 1.
Note : On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.

Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2.

Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.

IS200 Caulking Instructions

  1. After securing fixture to the wall it is recommended that the gap between the wall and the fixture backplate be sealed on the top and both sides, with a good quality waterproof caulk or silicone sealant (NOT INCLUDED) – see Drawing 1.
  2. After securing the fixture in place it is recommended that the gap between the mounting top and fixture base be sealed with any good quality waterproof caulk or silicone sealant (not included). It is also recommended that a small bead of caulk or sealant be put under the ball knobs used to mount the fixture – see Drawing 2.HINKLEY-2560-Alford-Place-Tall-Wall-Mount-Lantern-fig0- \(9\)

HINKLEY 33000 Pin Oak Parkwa y, Avon Lak e, OH 440 12800 .446.5539/440.653.5500 hinkley.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals