EdgecorE AS4625-54T Ethernet Switch User Guide
- June 13, 2024
- Edgecore
Table of Contents
EdgecorE AS4625-54T Ethernet Switch
Product Information
The product is an Ethernet Switch with the model numbers AS4625-54T and AS4625-54P. The package contents include:
- AS4625-54T/AS4625-54P (includes 2 PSUs)
- Rack Mounting Kit–2 brackets and 8 screws
- USB Micro-B to USB-A cable
- Four adhesive rubber feet
- Console cable–RJ-45 to DE-9
- (Optional) AC power cord
- Documentation–Quick Start Guide (this document) and Safety and Regulatory Information
The AS4625-54T model features:
- 48 x 1G RJ-45 ports
- 6 x 1G/10G SFP+ ports
- 1000BASE-T RJ-45, RJ-45 console, Micro-USB storage port
- 2 x AC PSUs
- 2+1 fixed redundant fans
- Grounding screw
The AS4625-54P model features:
- 40 x 1G RJ-45 PoE ports (30 W per port)
- 8 x 1G RJ-45 PoE ports (90 W per port)
- 6 x 1G/10G SFP+ ports
- 1000BASE-T RJ-45, RJ-45 console, Micro-USB storage port
- 2 x AC PSUs
- 2+1 fixed redundant fans
- Grounding screw
The device also includes status LEDs for various functions such as system status, PSU status, fan status, PoE status, and port activity.
Product Usage Instructions
Installation
Note:
The device has the Open Network Install Environment (ONIE) software installer
preloaded, but no software image. Information about compatible software can be
found at www.edge-core.com.
Note:
The drawings in this document are for illustration only and may not match your
particular model.
-
Mount the Device in a Rack
-
Attach the brackets using the included flathead M4x8 screws.
-
Secure the device in the rack using the screws and cage/clip nuts supplied with the rack. Alternatively, you can install the device on a desktop or shelf using the included adhesive rubber feet.
-
Ground the Device
-
Verify that the rack is properly grounded and in compliance with international and local standards. Ensure there is a good electrical connection to the grounding point on the rack (no paint or isolating surface treatment).
-
Attach a grounding wire (#14 AWG/1.5 mm2, green with yellow stripe) to the grounding point on the device’s rear panel or side panel.
-
Connect the other end of the wire to rack ground.
-
Connect Power
Install one or two AC PSUs in the device if they are not already installed in the factory. Then connect an external AC power source to the PSUs. -
Make Network Connections
- RJ-45 Ports: Connect Category 5, 5e, or better twisted-pair cable.
- SFP+ Ports: Install transceivers and then connect fiber optic cabling to the transceiver ports. Alternatively, connect AEC/AOC/DAC cables directly to the SFP+ slots.
The following transceivers are supported in the SFP+ ports:
- 10GBASE-SR, LR, CR, T
- 1000BASE-SX, LX, T
For further instructions on FRU replacement and PSU replacement, please refer to the user manual.
Package Contents
- AS4625-54T/AS4625-54P (includes 2 PSUs)
- Rack Mounting Kit—2 brackets and 8 screws
- USB Micro-B to USB-A cable
- Four adhesive rubber feet
- Console cable—RJ-45 to DE-9
- (Optional) AC power cord
- Documentation—Quick Start Guide (this document) and Safety and Regulatory Information
Overview
AS4625-54T
- 48 x 1G RJ-45 ports
- 6 x 1G/10G SFP+ ports
- 1000BASE-T RJ-45, RJ-45 console, Micro-USB storage port
- 2 x AC PSUs
- 2+1 fixed redundant fans
- Grounding screw
AS4625-54P
- 40 x 1G RJ-45 PoE ports (30 W per port)
- 8 x 1G RJ-45 PoE ports (90 W per port)
- 6 x 1G/10G SFP+ ports
- 1000BASE-T RJ-45, RJ-45 console, Micro-USB storage port
- 2 x AC PSUs
- 2+1 fixed redundant fans
- Grounding screw
Status LEDs
- Reset button
- System — Green (OK), Amber (fault detected)
- PSU1/2 — Green (OK), Amber (fault)
- FAN — Green (OK), Amber (fault)
- LOC — Blinking Amber (switch locator)
- PoE — Green (OK), Amber (near PoE budget)
- RJ-45 Port LEDs: Green (link), Amber (link with PoE)
- SFP+ Port LEDs: Green (10G), Amber (1G)
- RJ-45 Management Port LEDs: Left (link), Right (activity)
FRU Replacement
PSU Replacement
- Remove the power cord.
- Press the release latch and remove the PSU.
- Install replacement PSU.
PSU Replacement
- Remove the power cord.
- Press the release latch and remove the PSU.
- Install replacement PSU.
Installation
- Warning: For a safe and reliable installation, use only the accessories and screws provided with the device. Use of other accessories and screws could result in damage to the unit. Any damages incurred by using unapproved accessories are not covered by the warranty.
- Caution: The device must be installed in a restricted-access location.
- Note: The device has the Open Network Install Environment (ONIE) software installer preloaded, but no software image. Information about compatible software can be found at www.edge-core.com.
- Note: The drawings in this document are for illustration only and may not match your particular model.
-
Mount the Device in a Rack
-
Use the included flathead M4x8 screws to attach the brackets.
-
Use the screws and cage/clip nuts supplied with the rack to secure the device in the rack.
Note: The device can also be installed on a desktop or shelf using the included adhesive rubber feet. -
Ground the Device
-
Verify Rack Ground
Ensure the rack is properly grounded and in compliance with international and local standards. Verify that there is a good electrical connection to the grounding point on the rack (no paint or isolating surface treatment). -
Attach Grounding Wire
Attach a grounding wire (#14 AWG/1.5 mm2, green with yellow stripe) to the grounding point on the device’s rear panel or side panel. Then connect the other end of the wire to rack ground.
Caution: The earth connection must not be removed unless all supply connections have been disconnected.
-
-
Connect Power
Install one or two AC PSUs in the device, if they are not already installed in the factory. Then connect an external AC power source to the PSUs. -
Make Network Connections
-
RJ-45 Ports
Connect Category 5, 5e or better twisted-pair cable. -
SFP+ Ports
Install transceivers and then connect fiber optic cabling to the transceiver ports. Alternatively, connect AEC/AOC/DAC cables directly to the SFP+ slots.
The following transceivers are supported in the SFP+ ports:
* 10GBASE-SR, LR, CR, T
* 1000BASE-SX, LX, T
-
Make Management Connections
-
Micro-USB Port
Use the included Micro-USB cable to connect to an external storage device. -
Mgmt RJ-45 Port
Connect Category 5, 5e or better twisted-pair cable. -
RJ-45 Console Port
Use the included RJ-45-to-DE-9 null-modem console cable to connect to a PC running terminal emulator software. Use a USB-to-male DE-9 adapter cable (not included) for connections to PCs that do not have a DE-9 serial port. -
Configure the serial connection: 115200 bps, 8 characters, no parity, one stop bit, 8 data bits, and no flow control.
-
Console cable pinouts and wiring:
Device’s RJ-45 Console/Null Modem/PC’s 9-Pin DTE Port -
6 RXD (receive data) <—————- 3 TXD (transmit data)
-
3 TXD (transmit data) —————-> 2 RXD (receive data)
-
4,5 SGND (signal ground) —————— 5 SGND (signal ground)
-
Hardware Specifications
-
Size (WxDxH) 440 x 350.35 x 44 mm (17.32 x 13.79 x 1.73 in.)
-
Weight
- AS4625-54T: 5.8 kg (12.77 lb), includes two PSUs
- AS4625-54P: 6.6 kg (14.55 lb), includes two PSUs
-
Temperature
- Operating: 0° C to 45° C (32° F to 113° F)
- Storage: -40° C to 70° C (-40° F to 158° F)
-
Humidity Operating: 5% to 95% (non-condensing)
-
Power Consumption (at 25° C)
- AS4625-54T: 150 W max.
- AS4625-54P:
- Low-line (90–136 VAC): 2000 Watts max.
- High-line (180–264 VAC): 2400 Watts max.
-
System Input Rating (per PSU)
-
AS4625-54T:
100–120 VAC, 50/60 Hz, 4 A max.
200–240 VAC, 50/60 Hz, 2 A max. -
AS4625-54P:
100–120 VAC, 50/60 Hz, 12 A max.
200–240 VAC, 50/60 Hz, 8.5 A max.
-
-
PoE Budget AS4625-54P:
- Low-line: 850 W for 1 PSU, 1850 W for 2 PSUs
- High-line: 1050 W for 1 PSU, 1920 W for 2 PSUs
Regulatory Compliances
Emissions
- EN 55032
- EN 61000-3-2
- EN 61000-3-3
- FCC Title 47, Part 15, Subpart B, Class A
- VCCI-CISPR 32
- BSMI Class A
- IECS-003 Issue 7
- AS/NZS CISPR 32
- KS C 9832
Immunity
- EN 55024/EN 55035
- KS C 9835
- IEC 61000-4-2/3/4/5/6/8/11
Safety
- UL (CSA 22.2 No 62368-1 & UL 62368-1)
- CB (IEC/EN 62368-1, 2nd & 3rd Ed)
- BSMI CNS 15598-1
Taiwan RoHS CNS 15663
Warranty
Warranty Information and Technical Support
Registering your product enables you to receive a more efficient warranty
service. Be sure to register at www.edge-core.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>