HINKLEY 83445 Armstrong Grove 18 Inch Chandelier Lamps Instruction Manual

June 13, 2024
HINKLEY

HINKLEY 83445 Armstrong Grove 18 Inch Chandelier Lamps

Product Information

This product is a fixture that includes a wire stem, wire, cage, socket, socket ring, shade,and screws. It is designed to be assembled and installed for use as a lamp. The product is suitable for indoor and outdoor use.

Product Usage Instructions

  1. Find a clear area to work and unpack the fixture and glass from the carton.

  2. Carefully review the instructions prior to assembly.

  3. For assembly of the fixture:

  4. Place the cage over the socket.

  5. Use the socket ring to secure the cage.

  6. Secure the shade to the cage using the provided screw.

  7. Repeat the process for the other shade.

  8. The fixture can now be lamped and powered on.

  9. For wiring instructions:

    • Indoor Fixtures:
    1. Connect the positive supply wire (typically black or the smooth, unmarked side of the two-conductor cord) to the positive fixture lead using an appropriately sized twist-on connector.
    2. Connect the negative supply wire (typically white or the ribbed, marked side of the two-conductor cord) to the negative fixture lead.
    3. Refer to the grounding instructions below to complete all electrical connections.
    • Outdoor Fixtures:
    1. Connect the positive supply wire (typically black or the smooth unmarked side of the two-conductor cord) to the positive fixture lead using an appropriately sized twist-on connector.
    2. Connect the negative supply wire (typically white or the ribbed, marked side of the two-conductor cord) to the negative fixture lead.
    3. Cover the open end of connectors with silicone sealant to form a watertight seal. If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall.
    4. Refer to the grounding instructions below to complete all electrical connections.
  10. For grounding instructions:

    • Flush Mount Fixtures:
      Fasten the fixture ground wire (typically copper or green plastic coated) to the fixture mounting strap using the ground screw.

    • Chain Hung Fixtures: (additional instructions not provided in the text-extract)

Please note that if you are unsure about any step or if new wiring is required, it is recommended to consult a qualified electrician or local authorities for code requirements and assistance.

Assembly Instructions

  1. Find a clear area in which you can work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly.

Shut off electrical current befoer starting. If the fixture you are replacing is turned on and off by a wall switch, simply turn the switch off. If not, remove the appropriate fuse (or open the circuit breakers) until the fixture is dead.• DO NOT restore current – either by fuse, breaker, or switch – until the new fixture is completely wired and in place.

  1. Determine the desired height the pendant will be installed.
  2. The fixture is supplied with assorted stem sizes. Determine what combinations of stems are needed to achieve desired length – see Drawing 1 and 2 for part reference.
  3. Slip stems over wire and thread first stem onto top of pendant, longest stem first. Repeat this process until all required stems are threaded together.
  4. Next slide screw collar ring (S) along wire and over stems, followed by the canopy (C).
  5. Now slip wires through the center hole in the swivel attached to the mounting strap (A). Then thread swivel into top of last stem.

Pendant is now ready for install

  1. To mount assembled pendant body to ceiling, first make all the necessary wiring connections using instruction sheet IS18 provided.

  2. After all wiring connections are complete, tuck all wires into junction box (J) – see Drawing 2.

  3. Now attach mounting strap (A) to junction box (J) using two screws (B) NOT PROVIDED.
    NOTE: the back of mounting strap (A) should be flush against the ceiling. It should not be recessed into the ceiling or off of the ceiling surface.

  4. Next slip canopy (C) up against the ceiling and thread screw collar (S) onto exposed portion of threaded section (L) and tighten to secure canopy to ceiling.

  5. Refer to assembly instructions for attaching glass to pendant body.

  6. Place cage (5) over socket (2)

  7. Use socket ring (4) to secure cage (5)

  8. Secure shade (3) to cage (5) using screw (6)

  9. Repeat process for the other shade

  10. Fixture can now be lamped and powered on

Wiring grounding Instructions

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS

Wiring Instructions

Indoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Please refer to the grounding instructions below to complete all electrical connections

Outdoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3.

  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).

  3. Cover open end of connectors with silicone sealant to form a watertight seal.
    If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.

  4. Please refer to the grounding instructions below to complete all electrical connections.

Grounding Instructions

Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) – see Drawing 1.

Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.

Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2.

Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.

LARK 33000 PIN OAK PARKWAY, AVON LAKE, OH 44012 LarkLiving.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals