ecler MIMO88SG Digital Matrix User Manual
- June 13, 2024
- ecler
Table of Contents
- MIMO88SG Digital Matrix
- IMPORTANT REMARK
- IMPORTANT SAFETY INSTRUCTIONS
- IMPORTANT NOTE
- INTRODUCTION
- INSTALLATION
- CLEANING
- FUNCTION LIST
- FUNCTION DIAGRAMS
- TECHNICAL CHARACTERISTICS
- BLOCK DIAGRAMS
- TP-NET PROTOCOL INTRODUCTION
- MIMO88SG / MIMO1212SG (SINGLE) DIGITAL MATRIX
- MIMO88SG CONFERENCE DIGITAL MATRIX
- ERROR CODES FOR ECLERNET DEVICES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MIMO88SG / 1212SG
DIGITAL MATRIXES
Installation Digital Matrix
MIMO88SG Digital Matrix
USER MANUAL
IMPORTANT REMARK
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
WARNING: SHOCK HAZARD – DO NOT OPEN AVIS: RISQUE DE CHOC ELECTRIQUE – NE
PAS OUVRIR
The lightning flash with arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of uninsulated “dangerous voltage”
within the product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
WARNING (If applicable): The terminals marked with symbol of may be of
sufficient magnitude to constitute a risk of electric shock. The external
wiring connected to the terminals requires installation by an instructed
person or the use of ready-made leads or cords.
WARNING: To prevent fire or shock hazard, do not expose this equipment to
rain or moisture.
WARNING: An apparatus with Class I construction shall be connected to a
mains socket-outlet with a protective earthing connection.
IMPORTANT SAFETY INSTRUCTIONS
-
Read these instructions.
-
Keep these instructions.
-
Heed all warnings.
-
Follow all instructions.
-
Do not use this apparatus near water.
-
Clean only with dry cloth.
-
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
-
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
-
Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third
prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. -
Protect the power cord from being walked on or pinched particularly at the plugs, convenience receptacles, and at the point where they exit from the apparatus.
-
Only use attachments/accessories specified by the manufacturer.
-
Unplug the apparatus during lightening sorts or when unused for long periods of time.
-
Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. -
Disconnecting from mains: When switching off the POWER switch, all the functions and light indicators of the unit will be stopped, but fully disconnecting the device from mains is done by unplugging the power cable from the mains input socket. For this reason, it always shall remain easily accessible.
-
Equipment is connected to a socket-outlet with earthing connection by means of a power cord.
-
The marking information is located at the bottom of the unit.
-
The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on apparatus.
-
This product is for indoor use only.
NOTE: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
WARNING: This product must not be discarded, under any circumstance,
asunsorted urban waste. Take to the nearest electrical and electronic
wastetreatment centre.
NEEC AUDIO BARCELONA, S.L. accepts no liability for any damage that may
be caused to people, animal or objects due to failure to comply with the
warnings above.
IMPORTANT NOTE
Thank you for choosing our Ecler MIMO88SG / 1212SG Installation Digital
Matrix!
It is VERY IMPORTANT to carefully read this manual and to fully understand its
contents before any connection in order to maximize your use and get the best
performance from this equipment.
To ensure optimal operation of this device, we strongly recommend that its
maintenance be carried out by our authorised Technical Services.
All ECLER products are covered by warranty, please refer to www.ecler.com or
the warranty card included with this product for the period of validity and
conditions.
INTRODUCTION
The MIMO SG is a series of fully programmable digital audio matrixes, with the following features:
- 8 (MIMO88SG) or 12 (MIMO1212SG) balanced MIC/LINE inputs (independent phantom power per input channel).
- 8 (MIMO88SG) or 12 (MIMO1212SG) balanced LINE outputs.
- 8 (MIMO88SG) or 12 (MIMO1212SG) GPI control ports (General Purpose Input).
- Programming and remote management via Ethernet using EclerNet Manager (or point to point, with a direct CAT5 cable, or from an Ethernet network).
- Remote control via UCP (User Control Panel) clients on Ethernet: simultaneous clients with customized control panel, such as WPNETTOUCH Ecler, Android®, iOS®, Windows®, etc.
- Remote control from third party external devices. (Crestron, AMX, Vity, Medialon, etc. Registered trademarks of their manufacturers). TP-NET protocol, via Ethernet or RS-232 ports.
- Remote control bus for WPNETTOUCH digital panels and MPAGE16 messaging consoles (paging).
- Configuration memory (presets) management.
- Scheduled events based on calendar.
- WPNET4KV and WPNET8K compatible control panels (using specific retrocompatible Firmware*).
- For more information see WPNET4KV and WPNET8K user’s manual.
- Extensive DSP available:
o Routing matrix/mixer, from any input to any output with adjustable level for crossover points (independent mixes of different inputs for each output).
o Mono or stereo channel processing.
o Level control, mute, vu-meters and phase adjustment for inputs and outputs.
o Internal signal generator (sine wave, pink noise, white noise, polarity test).
o Parametric EQ on inputs and outputs.
o Delay on inputs and outputs.
o Gate/compressor on input channels.
o Compressor/limiter on outputs.
o Input channel priority assignment (ducking).
o Virtual and physical messaging consoles (paging).
o Standard MIMO88SG / MIMO1212SG firmware version (for generic use) and alternative version, for conferencing applications (MIMO88SG / MIMO1212SG CONFERENCE version). Both firmware versions are compatible with the MIMO88SG / MIMO1212SG hardware which can be freely updated with anyone of them.
- Extensive DSP available:
The MIMO SG programming is done with EclerNet
Manager. Please refer to
EclerNet
Manager Software manual at www.ecler.com for more
information.
INSTALLATION
5.1. Location, assembly, ventilation
MIMO SG series has been especially designed to be installed in a standard 19″
rack, taking up 1U.
It is very important not to enclose the MIMO SG or expose it to extreme
temperatures as it generates heat. It’s also necessary to promote the passage
of fresh air through the ventilation holes of the chassis, leaving at least
one rack unit off between each device and installed above and below it in the
rack frame.
If the setup has several amplifiers in the same rack or in a closed cabinet
with doors, it is highly recommended to supply them forced ventilation,
installing fans at the upper and lower ends. This upward air flow will help to
dissipate the heat generated inside.
5.2. Connection to an AC outlet and switching on
All models in the MIMO SG series operate under voltages between 90 and 264 V
at 47 to 63 Hz. This device features an over dimensioned power supply that
adapts to the mains voltage in any country of the world with no need to make
any adjustments.
On the rear panel, there is a power switch for the unit next to the IEC power
connector.
On the front panel, a LED lights up when the unit is switched on.
The mains cables must not be near the shielded cables carrying the audio
signal, as this could cause humming.
5.3. Signal input connections
The rear panel of a MIMO SG unit offers 8 (MIMO88SG) or 12 (MIMO1212SG)
balanced analogue signal inputs, “IN”, accepting both line and microphone
level signals. Input signal type selection and management are carried out from
EclerNet Manager application. Please refer to EclerNet Manager Software manual
at www.ecler.com for more information.
Signal input connectors are 3 position screw terminal block. The wiring is:
Hot or direct signal > Terminal +
Cold or inverted signal > Terminal –
Ground > Terminal ⊥
For unbalanced connection short-circuit pin ⊥ to pin -.
5.4. Audio Output Connections
The rear panel of a MIMO SG offers 8(MIMO88SG) or 12 (MIMO1212SG)
analoguesignal outputs “OUT”, all balanced and acceptingline level signals.
Signal output connectors are 3 position screw terminal block. The wiring is:
Hot or direct signal > Terminal +
Cold or inverted signal > Terminal –
Ground > Terminal ⊥
For UNBALANCED connections, leave the – terminal unconnected.
5.5. ETHERNET port for programming and control
An RJ45 type connector allows connecting the equipment to an Ethernet network:
- Management from EclerNet Manager application. Please refer to EclerNet Manager Software manual at www.ecler.com for more information.
- Possibility of direct connection (point to point) between a computer and a MIMO SG unit.
- Connection to third party other devices. (Crestron, AMX, Vity, Medialon, etc. Registered trademarks of their manufacturers). Protocol used: Ecler TP-NET. See the TP-NET protocol manual for more information.
- Connection to WPNETTOUCH units (remote control of an entire network of EclerNet devices through custom graphic panels).
5.5.1 Factory Preset Network settings
The factory default network settings for EclerNet Manager compatible devices
are as follows:
- IP: 192.168.0.100
- Mask: 255.255.255.0
- Gate: 192.168.0.1
- UDP Port: 2210
5.6. REMOTE port for digital remote controls
The REMOTE port allows the connection of digital remote-control devices, such
as the WPNETTOUCH wall panel or the MPAGE16 paging console. The REMOTE port is
connected to the digital control bus the remote devices are daisy-chained to,
the last one being loaded with a 120 Ω termination resistor between CAN HIGH
and CAN LOW.
Refer to the remote device documentation (WPNETTOUCH, MPAGE16, etc) for more
information about your connection and controls.
Please refer to EclerNet Manager Software manual at
www.ecler.com for more information about programming a
MIMO SG to manage the remote devices that are connected to the REMOTE port.
5.7. GPI Remote Control Ports
The rear panel of the MIMO SG offers 8 (MIMO88SG) or 12 (MIMO1212SG) GPI
inputs for 0-10 VDC continuous control voltage. Each of these inputs can be
connected to an external physical device (potentiometer, contact closure,
continuously variable voltage 0-10V DC, etc.) and assigned to a MIMO SG
function, as for example:
- Input, output channel or matrix crosspoint volume remote control by means of a WPaVOL physical knob or an Ecler WP Series’ WPVOL-IR remote control
- MUTE or SOLO activation/deactivation by means of a switch or contact closure
- Recalling a preset with a push button or contact closure
GPI connectors are screw terminal blocks with three-contacts. The wiring is as follows:
Positive, + 12 VDC > Pin +
Variable voltage, 0-12 VDC > Pin ↑
Ground > Pin ⊥
Jumpers position: ALOG / LIN → LIN position
+12 / +10 → +12 position
WPaVOL-SR connection to MIMO serial GPI ports
Connecting cables can be up to 500 meters with a minimum section of 0.5 mm 2.
Consult your ECLER dealer or www.ecler.com about the WP series remote control
wall panels and other accessories available for connection to the GPI port.
5.8. Remote control RS-232 Port
The built-in RS-232 port in the rear panel allows an external device to
communicate with a MIMO SG unit via serial connection. Said connection uses
the TP-NET protocol syntax so to enable the external device to obtain the
value of any of the parameters of the MIMO SG unit (by “GET” commands) and/or
modify said values (“SET” commands). See the TPNET protocol manual for more
information.
The serial connection should comply with the following specifications:
- Baud rate: 57600 (fixed, no auto negotiation)
- Data bits: 8
- Parity: None
- Stop bits: 1
- Flow control: None
WIRING RS232 – DB9
RS232| DB9
Tx| Pin 2 (RxD)
Rx| Pin 3 (TxD)
Gnd| Pin 5 (Signal Gnd)
The following elements are available on the MIMO SG series front panel:
- Input LED indicators: indicate the presence of audio signal at the unit’s input, and its intensity level (green, amber and red indicate in this order the increased intensity level)
- Output LED indicators: indicate the presence of audio signal at the unit’s output, and its intensity level (green, amber and red indicate in this order the increased intensity level)
- Status LED indicators (STATUS):
o DATA: Off: there is no connection to EclerNet Manager even if connected to Ethernet. On: connected to EclerNet Manager or to other third party application via TP-NET protocol. Flashing: data traffic with EclerNet Manager or another application.
o POWER: Illuminates when the unit is in operation. It flashes if there is an error in the unit or if firmware is not correct. It also flashes when you update firmware
CLEANING
The front panel should not be cleaned with dissolvent or abrasive substances because silk-printing could be damaged. To clean it, use a soft cloth slightly wet with water and neutral liquid soap; dry it with a clean cloth. Be careful that water never gets into the unit through the holes of the front panel.
FUNCTION LIST
- Input signal indicators, INPUTS
- Output signal indicators, OUTPUTS
- Data traffic indicator, DATA
- Power on indicator, POWER
- Signal output screw terminal, OUT
- Signal input screw terminal, IN
- RJ-45 connector, ETHERNET
- Screw terminals for digital remote control, REMOTE
- Screw-assembled remote-control terminals via the TP-NET, RS-232 protocol
- Screw terminals for continuous voltage control, GPI
- Mains socket
- Fuse holder
- Power switch
FUNCTION DIAGRAMS
8.1 MIMO88SG
8.2. MIMO1212SG
TECHNICAL CHARACTERISTICS
9.1. MIMO88SG
DSP|
---|---
DSP
Sampling Rate
Latency IN to OUT| 2x 32/64bit
48kHz
<2.9ms
Converters
Resolution Dynamic Range| 24bit AKM
AD:110dB, DA: 115dB
Analogue
x8 Input/Output
Analogue Input headroom
Max. output level
Input sensitivity @ 0dBV out Input Impedance Phantom power Frequency response
(-3dB)
Flatness THD+Noise @ 1kHz, 0dBV input (line)
THD+Noise @ 1kHz, -40dBV input (mic.)
Output Noise floor FFT (20Hz – 20kHz) Interchannel crosstalk (20Hz – 20kHz)
Channel Leakage (20Hz – 20kHz)
CMRR 20Hz- 20kHz| Terminal block (Symmetrical)
+27dBV = +30dBu
+18dBV = +21dBu
From -50dBV to +10dBV
in 0.5dB step
Balanced, >4kW
+42VDC, 5mA max software switched
5Hz to 24kHz
better than ±0.1dB
<0.004%
<0.008%
better than 115dB
better than 90dB (100dB typ.)
better than 100dB (115dB typ.)
65dB typ.
Processing
Parametric Eq. Types
(4 max per input)
(6 max per input)
High & Low pass output Crossover
filters (x8)
Input Noise Gate (x8)
Input Compressor / Limiter (x8)
Input Frequency Shifter (x4)
(Feedback Loop Reducer)
Output Limiter (x8)
Built in Signal Generator
Stereo Linking
Mix Matrix
Pager (x3)| Range: from Off to 0 dB
Mute: Yes
Signal Polarity reverse: Yes
Metering: VU+clip pre & post fader
Range: from Off to 0 dB
Mute: Yes
Solo: Yes
Signal Polarity reverse: Yes
Metering: VU+clip pre & post fader
Range: from 0 to +6 dB
from 0 to 1000 ms
Units: sec/ms/m/cm
from 0 to 1000 ms
Units: sec/ms/m/cm.
Bypass / On-Off all channels
Param Eq. Freq: 20Hz-20kHz; Gain: -60/+12 dB; Q: 0.3 to 200
Low & High Shelf 6/12 dB/oct
Low & High Pass 6/12 dB/oct
All Pass 1/2 order
Bypass On-Off
Butterworth in 6/12/18/24 dB/oct
Bessel in 12/18/24 dB/oct
Linkwitz-Riley in 12/24 dB/oct
Bypass On-Off
Threshold: from –80 dBV to +18 dBV
Depth: 0 dB to 80 dB
Attack time: from 0,1 ms. to 500 ms.
Hold time: from 10 ms. to 3000 ms.
Release time: from 10 ms. to 1000 ms.
Bypass On-Off
Threshold: from –36 dBV to +18 dBV
Ratio: 1:1 to inf:1 (limiter)
Knee: hard / soft
Attack time: from 0,1 ms. to 500 ms.
Release time: from 10 ms. to 1000 ms.
Make up gain: from 0 to +10 dB
Available on IN1 to IN4. ON / OFF function
Bypass On-Off
Threshold: from –36 dBV to +18 dBV
Attack time: from 0,1 ms. to 500 ms.
Release time: from 10 ms. to 1000 ms.
Sine: from 20 Hz to 20 kHz
Polarity: from 20 Hz to 20 kHz
White noise
Pink noise
Adjacent input / output channels
Linked processing
Matrix routing linked
Size: 8×8
Vol: Input, Output, Crosspoint
Mute: Set/Clear individual, row, column, all Input /output
Mono/stereo selector
Meter: Input /output VU and clip
Input: IN1 to IN8
Priorities: 3 (1 max, 3 min)
Depth: 0 dB to 80 dB
Attack time: from 5 ms. to 2000 ms.
Release time: from 50 ms. to 3000 ms.
Chime Source: None, Melody 1, Melody 2
Chime Volume: from –12 dB to 0 dB
Mechanical
Dimensions (WxHxD)
Weight| 482.6 x 44 x 253 mm / 19 x 1.73 x 9.96 in.
3.5kg
Supply
Mains
Power consumption| 90-264VCA 47-63Hz
45VA
Miscellaneous
Management Connectivity Remote Bus GPI Aux. Power Supply for Remotes & GPI
Time and date retention (battery) RTC accuracy| Ethernet Base-Tx 10/100Mb Auto
X-Over CAT5 up Over twisted pairs; up to 1km (see specific specs.)8, from 0 to
10VDC or TTL level
+12VDC, 1.2A. max. (short circuit protected)
100 hours approx. (ambient temperature depend±1 minute / month
Software
EclerNet Manager| From v3.03r4 version
9.2. MIMO1212SG
DSP|
---|---
DSP
SamplingRate
Latency IN to OUT| 2x 32/64bit
48kHz
<3.2ms
Converters|
Resolution
Dynamic Range| 24bit AKM
AD:110dB, DA: 115dB
Analogue|
12 Input/Output
Analogue Input headroom
Max. output level
Input sensitivity @ 0dBV out
Input Impedance
Phantom power
Frequency response (-3dB)
FlatnessTHD+Noise @ 1kHz, 0dBV input (line)
THD+Noise @ 1kHz, -40dBV input (mic.)
Output Noise floor FFT (20Hz – 20kHz)
Interchannel crosstalk (20Hz – 20kHz)
Channel Leakage (20Hz – 20kHz)
CMRR 20Hz- 20kHz| Terminal block (Symmetrical)
+27dBV = +30dBu
+18dBV = +21dBu
From -50dBV to +10dBV in 0.5dB step
Balanced, >4kΩ
+42VDC, 5mA max. software switched
5Hz to 24kHz
better than ±0.1dB
<0.004%
<0.008%
better than 115dB
better than 90dB (100dB typ.)
better than 100dB (115dB typ.)
65dB typ.
Processing|
Input Level (x12)
Output Level (x12)
Output Gain (x12)
Input Delay (x12)
Output Delay (x12)
Parametric Eq. Types
(4 max per input)
(6 max per input)
High & Low pass output
Crossover filters (x12)
Input Noise Gate (x12)
Input Compressor / Limiter (x12)
Input Frequency Shifter (x4)
(Feedback Loop Reducer)
Output Limiter (x12)
Built in Signal Generator
Stereo Linking
Mix Matrix
Pager (x3)| Range: from Off to 0 dB
Mute: Yes
Signal Polarity reverse: Yes
Metering: VU + clip pre & post faderRange: from Off to 0 dB
Mute: Yes
Solo: Yes
Signal Polarity reverse: Yes
Metering: VU + clip pre & post fader
Range: from 0 to +6 dB
from 0 to 1000 ms.
Units: sec/ms/m/cm.
from 0 to 1000 ms.
Units: sec/ms/m/cm.
Bypass / On-Off all channels
Param Eq. Freq: 20Hz-20kHz; Gain: -60/+12 dB; Q: 0.3 to 200
Low & High Shelf 6/12 dB/oct
Low & High Pass 6/12 dB/oct
All Pass 1/2 order
Bypass On-Off
Butterworth in 6/12/18/24 dB/oct
Bessel in 12/18/24 dB/oct
Linkwitz-Riley in 12/24 dB/oct
Bypass On-Off
Threshold: from –80 dBV to +18 dBV
Depth: 0 dB to 80 dB
Attack time: from 0,1 ms. to 500 ms.
Hold time: from 10 ms. to 3000 ms.
Release time: from 10 ms. to 1000 ms.
Bypass On-Off
Threshold: from –36 dBV to +18 dBV
Ratio: 1:1 to inf:1 (limiter)
Knee: hard / soft
Attack time: from 0,1 ms. to 500 ms.
Release time: from 10 ms. to 1000 ms.
Make up gain: from 0 to +10 dB
Available on IN1 to IN4. ON / OFF function
Bypass On-Off
Threshold: from –36 dBV to +18 dBV
Attack time: from 0,1 ms. to 500 ms.
Release time: from 10 ms. to 1000 ms.
Sine: from 20 Hz to 20 kHz
Polarity: from 20 Hz to 20 kHz
White noise
Pink noise
Adjacent input / output channels
Linked processing
Matrix routing linked
Size: 12×12
Vol: Input, Output, Crosspoint
Mute: Set/Clear individual, row, column, all
Input /output Mono/stereo selector
Meter: Input /output VU and clip
Input: IN1 to IN12
Priorities: 3 (1 max, 3 min)
Depth: 0 dB to 80 dB
Attack time: from 5 ms. to 2000 ms.
Release time: from 50 ms. to 3000 ms.
Chime Source: None, Melody 1, Melody 2
Chime Volume: from –12 dB to 0 dB
Mechanical|
Dimensions (WxHxD)
Weight| 482.6 x 44 x 253 mm / 19 x 1.73 x 9.96 in
3.2kg
Supply|
Mains
Power consumption| 90-264VCA 47-63Hz
75VA
Miscellaneous|
Management Connectivity
Remote Bus
GPI
Aux. Power Supply for Remotes & GPI
Time and date retention (battery)
RTC accuracy| Ethernet Base-Tx 10/100Mb Auto X-Over CAT5 up to 100m.
Over twisted pairs; up to 1km (see specific specs.)
12, from 0 to 10VDC or TTL level
+12VDC, 0,6A. max. (short circuit protected)
100 hours approx. (ambient temperature dependant)
±1 minute / month
Software|
EclerNet Manager| From v3.03r4 version
BLOCK DIAGRAMS
10.1. MIMO88SG
10.2. MIMO1212SG
TP-NET PROTOCOL
SOFTWARE
Third-Party NET
TP-NET PROTOCOL INTRODUCTION
The TP-NET protocol lets a client device (control device) get and/or set the
values of several parameters of the EclerNet compatible devices (MIMO and MIMO
SG series digital matrices, DUO-NET PLAYER, NXA digital audio manager series,
NZA amplifier series, NPA amplifier series, etc.), like volumes, mutes,
alarms, etc. It’s as well available for eMIMO1616 digital matrix, HUB series
digital zoner, MIMO7272DN and
MIMO4040CDN digital matrix.
The communication with these digital audio devices can be established using
Ethernet and the UDP/IP transport protocol, always by means of the 5800 UDP
port. A second option for this communication is using the RS-232 interface
that some of these compatible devices do also have (MIMO series, DUO-NET
PLAYER, NXA series, etc.). In this case, the serial connection must fulfil the
following specifications:
- Baud rate: 57600 (fixed, no autonegotiation) for all the devices, except for DUONET PLAYER, eMIMO1616, HUB series and MIMO4040CDN, which use 115200baud rate)
- Data bits: 8
- Parity: None
- Stop bits: 1
- Flow control: None
In case the Ecler device has an Euroblock connector for the RS-232 interface, the serial cable wiring, from the device’s connector to a standard DB9 serial interface connector, must be the following:
WIRING RS232- DB9
RS232| DB9
Tx| Pin 2 (RxD)
Rx| Pin 3 (TxD)
Gnd| Pin 5 (Signal Gnd)
The protocol is simple and direct, making it easy to read, write and modify
the generated code. It is based on messages with no begin and end delimiter:
each message is selfdelimited by the UDP packet size, which is defined with a
maximum of 80 characters. All the messages must be written in capitalletters.
To let some control systems (like CRESTRON®, EXTRON®, AMX®, RTI®, VITY®,
MEDIALON®, etc.) process the messages more easily, the EclerNet device adds
the character LF (0x0A) to the end of each message. This way the client can
buffer the messages to process them, if it’s required. The EclerNet device can
also handle several messages received in a single message packet by using the
LF delimiter.
The available messages are built with one or more fields separated with blank
spaces ( = blank space):
- SYSTEM
- GET
- SET
- INC
- DEC
- SUBSCRIBE
- UNSUBSCRIBE
- DATA
- ERROR
At the end of this document you’ll find all the available messages and their
parameters for each model of the EclerNet compatible devices.
The SYSTEM, GET, SET, INC, DEC, SUBSCRIBE & UNSUBSCRIBE messages can be sent
from the client to the EclerNet device. The DATA & ERROR messages can be sent
from the device to the client. The only exception is the SYSTEM PING message,
that is a SYSTEM type message that is sent from the EclerNet device when the
initial message from the client to the device was SYSTEM CONNECT PINGPONG.
The communication (using UDP or RS-232) starts when a client sends the message
SYSTEM CONNECT to the EclerNet device. As far as the UDP communication
requires no connection (unlike the TCP), the EclerNet device stores this
client’s IP address, and then uses it as the destination IP address for the
messages that it generates (DATA & ERROR). After receiving the SYSTEM CONNECT
message, the device dumps its entire configuration using several consecutive
DATA messages.
The communication can be terminated by two methods:
- Manually: when the client sends the SYSTEM DISCONNECT message, cancelling all the subscriptions and stopping the DATA & ERROR messages
- Automatically: in case the initial message was SYSTEM CONNECT PINGPONG and the client didn’t get any SYSTEM PONG message in a period longer than 10 seconds (presuming a communication breakdown).
The SET messages don’t have an automatic acknowledgement with a DATA message sent from the EclerNet device after it has processed the SET command. The client must update the values itself and must send the needed GET message if it requires confirmation from the device.
NOTES:
-
The numerical values are always integer numbers without +, –, comma or dot symbols.
-
[PINGPONG] is an optional parameter used to configure the device-client communication with a periodical check, to see whether the client or the device have terminated it. When configured this way, the device sends a SYSTEM PING once per second, and the client must answer with a SYSTEM PONG message. If anyone doesn’t get these messages along a 10 seconds period, the communication will be considered terminated
- &
-
is a numerical value that identifies one available Preset stored in the EclerNet device’s memory. -
, y
are numerical values in the [0..100] range that define values in a scale equivalent to [-inf..0] dB. -
& are numerical values within the [1..8] range for the MIMO88 configured as 8×8 matrix masters (single units), and [1..16] for MIMO88 couples configured as 16×16 matrix masters. For the NXA series GPI values can be within the [1..4] or [1..6] range, depending on model. For the MIMO7272DN and MIMO4040CDN GPI and GPO values can be within [1..8]. -
is a numerical value within the [0..100] range that indicates the value of an analogue GPI input. For a digital input only 0 or 100 are the possible values. -
is a numerical value within the [0..1] range: it can only be 0 or 1 (opened or closed GPO). -
is a numerical value within the [1..10] range that sets the VU-meter refresh rate, or the number of times the vumeters’ values are sent per second (by default = 3). -
“
” is the device name inside double quotation marks, to allow for names with blank spaces. -
is a numerical value for an error code. -
“
” is a text chain inside double quotation marks, containing an error description. -
is a numerical value that identifies a Virtual Control. It can be within a [1..64] range for MIMO88SG, MIMO88SGCONF, , MIMO1212SG and MIMO1212SGCONF models.
MIMO88SG / MIMO1212SG (SINGLE) DIGITAL MATRIX
IMPORTANT NOTE: The communication must be started with the client sending the first message SYSTEM CONNECT to the EclerNet device. Otherwise, the commands from the client to the EclerNet device will be ignored. See TP-ET PROTOCOL INTRODUCTION chapter for additional information.
TYPE| PAFtAM1| PARAM2| PARAM3| PARAM4|
DESCRIPTION
---|---|---|---|---|---
SYSTEM| CONNECT| (PINGPONG)| | | Saves the client IP address for responses and
then dumps current device status (with DATA messages)
DISCONNECT| | | | Cancel subscriptions and terminates communication
SUBSCRIPTION RATE| <Rate:.| | | Alive message from device
PING| | | | Alive message from device
PONG| | | | Alive ACK message from client
GS| ALL| | | | Dumps current device status (with DATA messages)
PRESET| | | | Gets the current PRESET
(LEVEL| | | | Gets the current LEVEL of an Input Channel
OLEVEL|
Note: INC and DEC commands are replied with a DATA command from the device with the resulting LEVEL value, after it has been increased or decreased. When the INC or DEC command tries to adjust a LEVEL value beyond its minimum or maximum limits, no reply (DATA command) will be produced.
TYPE| PARAM1| PARAM2| PARAM3| PARAM4|
DESCRIPTION
---|---|---|---|---|---
DATA| PRESET|
!LEVEL| |
OLEVEL|
XLEVEL| |
(MUTE| | YES/NO| | Shows the current MUTE status of an Input
Channel
OMUTE|
XMUTE| |
VIRTUAL_CONTROL|
IVU| | |
OVU| |
GPI| |
GPO|
MIMO88SG)
INFO_NAME| “
INFO_MODEL|
INFO_VERSION|
INFO_MAC|
ERROR|
MIMO88SG CONFERENCE DIGITAL MATRIX
IMPORTANT NOTE: The communication must be started with the client sending
the first message SYSTEM CONNECT to the EclerNet device.
Otherwise, the commands from the client to the EclerNet device will be
ignored. See TP-NET PROTOCOL INTRODUCTION chapter for additional information.
This MIMO88SG CONFERENCE firmware version shares the same hardware with the
standard MIMO88SG unit, just uploading the CONFERENCE firmware version to it,
and shares as well the same TP-NET commands in the above table, adding to them
these new ones:
TYPE| PARAM1| PARAM2| PARAM3| PARAM4|
DESCRIPTION
---|---|---|---|---|---
GET| GATE| | | | Gets the current status of the NOISE GATE for inputs 1 to 8
AUTOMIXER| | | | Gets the current status of the AUTOMIXER function for inputs
1 to 8
SUBSCRIBE| GATE| | | | Subscribes to the status of the NOISE GATE for inputs 1
to 8
AUTOMIXER| | | | Subscribes to the status of the AUTOMIXER function for inputs
1 to 8
UNSUSCRIBE| GATE| | | | Unsubscribes to the status of the NOISE GATE for
inputs 1 to 8
AUTOMIXER| | | | Unsubscribes to the status of the AUTOMIXER function for
inputs 1 to 8
DATA| GATE| sl s2 s3 s4 s5 s6 s7 s8| | | Shows the current NOISE GATE status
(0 = open / 1 = closed) for the 8 inputs channels (sl to s8, status of the
gate for inputs 1 to 8)
AUTOMIXER| sl s2 s3 s4 s5 s6 s7 s8| | | Shows the current status for input
channels in the Automixer section (0 = disabled or bellow threshold in the
automixer / 1 = enabled and beyond threshold, but queued, not in the automatic
mix / 2 = enabled, beyond threshold and into the automatic mix) for the 8
inputs channels (sl to s8, status of the automixer function for inputs 1 to 8)
ERROR CODES FOR ECLERNET DEVICES
14.1. COMMON ERROR CODES (to all EclerNet – TP-NET compatible devices)
ERROR ID | DESCRIPTION |
---|---|
0 | TPNET_ERROR_NONE = 0, |
1 | TPNET_ERROR_INVALID_FIELD_TYPE, |
2 | TPNET_ERROR_INVALID_FIELD_PARAM1, |
3 | TPNET_ERROR_INVALID_FIELD_PARAM2, |
4 | TPNET_ERROR_INVALID_FIELD_PARAM3, |
5 | TPNET_ERROR_INVALID_FIELD_PARAM4, |
14.2 MIMO88SG, MIMO1212SG, MIMO88SG CONFERENCE & MIMO1212SG CONFERENCE SERIES SPECIFIC ERROR CODES
ERROR ID | DESCRIPTION |
---|---|
6 | UDP_ERROR_TIMEOUT_PONG, |
7 | UDP_ERROR_CONNECT_WHILE_CONNECTED, |
8 | UDP_ERROR_DISCONNECT_WHILE_UNCONNECTED, |
9 | UDP_ERROR_INVALID_CLIENT_IP, |
10 | UDP_ERROR_MESSAGE_TOO_LONG, |
11 | UDP_ERROR_UNSUPPORTED_MESSAGE, |
12 | UDP_ERROR_UNSUPPORTED_PRESET_NUMBER, |
13 | UDP_ERROR_UNSUPPORTED_INPUT_CHANNEL_NUMBER, |
14 | UDP_ERROR_UNSUPPORTED_OUTPUT_CHANNEL_NUMBER, |
15 | UDP_ERROR_UNSUPPORTED_GPI_NUMBER, |
16 | UDP_ERROR_INVALID_LEVEL_VALUE, |
17 | UDP_ERROR_INVALID_RATE_VALUE, |
All product characteristics are subject to variation due to production
tolerances.
NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements
in the design or
manufacturing that may affect these product specifications.
For technical queries contact your supplier, distributor or complete the
contact form on our website,
in Support / Technical requests.
Motors, 166‐168 08038 Barcelona
Spain ‐ (+34) 932238403
information@ecler.com
www.ecler.com
References
- EclerNet Manager: EclerNet | desktop application. Software.
- WPNET4KV: EclerNet Wall Control Panel. Digital Controls & Panels.
- WPNET8K: EclerNet Wall Control Panel. Digital Controls & Panels.