Assembly Instructions
Item No:83480

83480 Gold Wall Mirror

DRAWIN 1-MOUNTING start here

  1. Find a clear area in which you can work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly.

Mounting to junction box with or without plug

  1. Release mounting plate (A) by removing screws (C)
  2. Secure mounting plate (A) to junction box (J) using screws not provided
  3. If plug is not being used. remove plug at this time by removing wirenuts (N) and using plug (P) to cover hole left by removing plug -Drawing 3. Follow (IS-18) on the next page for wiring instructions
  4. Secure backplate (B) to mounting plate (A) using the previously removed screws (C)
  5. Fixture can now be plugged in if plug is being used

DRAWING 2 – Mounting without Jbox DRAWING 3- Removing plugHINKLEY
83480 Gold Wall Mirror - parts3

Non-junction box mounting

  1. Release mounting plate (A) by removing screws (C)
  2. Secure mounting plate (A) to wall using wall anchors (W) and screws (S)
  3. Secure backplate (B) to mounting plate (A) using the previously removed screws (C)
  4. Fixture can now be plugged in

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUC-TIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
DRAWING 4-shade AssemblyHINKLEY 83480 Gold Wall Mirror -
parts4 It is recommended that the socket and stem assembly (Y) is mounted to the wall prior to installing the glass. To install glass follow steps 1-5 below.

  1. To install glass (1) first thread coupler (2) off of the center stem assembly (A)- see drawing 1. This will allow the glass cap (3) to slide along the center stem freely.

  2. Prior to attaching glass the glass to the fixture body the glass to the fixture body the bulb should be installed

  3. Next take glass (1) and slip one side of bracket (Z) into top of glass.
    Now slide glass over and slip opposite side of bracket (Z) into the top of glass. Rest glass on tabs (T) of bracket (Z)

  4. Now slide glass cap (3) down over the hole in the top of glass and thread coupler (2) down the center stem to lock glass in place

  5. Fixture assembly is complete and power can be restored

Note: Arms have 60 degrees of motion on either side
DRAWING 5- Arm adjustmentHINKLEY 83480 Gold Wall Mirror -
parts5

I.S. 18 wiring grounding instructions

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS
Drawing 1 – Flush Mount

wiring instructions

Indoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Please refer to the grounding instructions below to complete all electrical connections

Outdoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – – – see Drawings 2 or 3.

  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).

  3. Cover open end of connectors with silicone sealant to form a watertight seal.
    If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.

  4. Please refer to the grounding instructions below to complete all electrical connections.

Drawing 2 – Chain Hung

grounding instructions

Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixturemounting strap (M) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw
Drawing 3 – Post-Mount Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.