HINKLEY 2561 Claire Facade Lamp Instruction Manual
- June 13, 2024
- HINKLEY
Table of Contents
HINKLEY 2561 Claire Facade Lamp
Product Information
- Product Name: HINKLEY
- Item Number: 28861
- Manufacturer: HINKLEY
- Address: 33000 Pin Oak Parkway, Avon Lake, OH 44012
- Contact: 800.446.5539 / 440.653.5500
- Website: hinkley.com.
Product Usage Instructions
- Post Mounting (Drawing 1)
- Find a clear area in which you can work.
- Unpack the fixture and glass from the carton.
- Carefully review the instructions prior to assembly.
- Make all necessary electrical connections following the wiring and grounding instructions (I.S. 18) and any additional directions. Ensure the power supply is turned off during installation.
- Mount the fixture body to the installed post by slipping the post fitter (1) of the fixture body (2) over the installed post and tightening the three machine screws (3) in the post fitter (1) to secure the fixture to the post.
- Cage Assembly (Drawing 2)
- Place the glass panels (3) into the cage (1) and fold down the tabs (6) to secure the glass.
- Lamp the fixture with an appropriate medium base bulb (2).
- Use the knobs (4) to secure the cage (1) to the top of the fixture (5).
- Glass Assembly (Drawing 3)
- Refer to the wiring instructions (I.S. 18) to complete the wiring and assembly of the glass.
Note: It is recommended to consult a qualified electrician or local authorities for code requirements if new wiring is required.
OVERVIEW
Assembly Instructions
- Find a clear area in which you can work.
- Unpack the fixture and glass from the carton.
- Carefully review instructions prior to assembly.
The installation of this fixture will be accomplished by first making all necessary electrical connections and then mounting the fixture body to the installed post, using the screws supplied with the fixture.
SAFETY WARNING:
READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL
DIRECTIONS. TURN THE POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS
REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE
REQUIREMENTS. Make electrical connections from supply wire to fixture lead
wires. Refer to the instruction sheet (I.S. 18) and follow all instructions to
make all necessary wiring connections. Then refer back to this sheet to
complete the installation of this fixture.
NOTE: MAKE SURE ALL WIRE NUTS USED ON ELECTRICAL CONNECTIONS ARE
SILICONE-FILLED
- Now follow the instruction sheet (IS-18) and make all necessary wiring connections.
- After the wiring is complete slip the post fitter (1) of the fixture body (2) over the installed post and tighten the three machine screws (3) in post fitter (1) to secure the fixture to the post.
OPTIONAL
The following mounting is optional but recommended in high-wind areas or coastal regions.
- Take main body assembly (2) slide the post fitter (1) over the install post and mark the location of the three threaded mounting holes.
- NOTE: MAKE SURE THE FIXTURE BODY IS ORIENTED IN THE POSITION YOU WANT, BEFORE MARKING THE HOLE LOCATIONS.
- Now remove the fixture body from the installed post and use a #29 drill bit (3.5mm). Drill holes at the marked locations.
- Tap drilled holes with an 8-32 UNC tap.
- Next, do all wiring connections follow (IS-18) provided, then slip wires into the post and slide post fitter (1) over installed post. Align holes previously drilled and tapped and thread in screws to secure the fixture.
- NOTE: If the post is thin-walled, 1/16” (2mm) thick or less replace machine screws with #8 stainless steel sheet metal screws
Drawing 2 – CAGE ASSEMBLY
- Place glass panels (3) into the cage (1) and fold down tabs (6) to secure the glass
- Lamp fixture with appropriate medium base bulb (2)
- Use knobs (4) to secure cage (1) to the top of fixture (5)
- Use the next page(IS18 ) of the IS to complete hanging and wiring
Drawing 3 -Glass Assembly
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS
Instructions
wiring instructions
- Indoor Fixtures
- Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with an appropriately sized twist on the connector – see Drawings 1 or 2.
- Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
- Please refer to the grounding instructions below to complete all electrical connections
- Outdoor Fixtures
- Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with an appropriately sized twist on the connector — see Drawings 2 or 3.
- Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
- Cover the open end of connectors with silicone sealant to form a watertight seal.
- If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box.
- If the wall surface is lap siding, use caulk and a fixture mounting platform.
- Please refer to the grounding instructions below to complete all electrical connections.
grounding instructions
-
Flush Mount Fixtures
-
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) – see Drawing 1.
- Note: On straps for screw-supported fixtures, first install the two mounting screws in the strap. Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
- Note: On straps for screw-supported fixtures, first install the two mounting screws in the strap. Any remaining tapped hole may be used for the ground screw.
-
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on the fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2.
-
Post-Mount Fixtures
-
Connect fixture ground wire (E) (typically copper or green plastic coated) to the power supply ground with an appropriately sized twist-on connector inside the post.
-
Cover the open end of the connector with silicone sealant to form a watertight seal – see Drawing 3.
CONTACT
- HINKLEY 33000 Pin Oak Parkway,
- Avon Lake,
- OH 44012 800.446.5539 / 440.653.5500
- hinkley.com.
- Item No: 28861
Read User Manual Online (PDF format)