ROGER TECHNOLOGY IS158 24V Flashing Light Instruction Manual
- June 13, 2024
- Roger Technology
Table of Contents
IS158 Rev.06 23/02/2023
IS158 24V Flashing Light
FIFTHY
Lampeggiante LED
Istruzioni originali Instructions and warnings for the installer
General safety precautions
Warning: incorrect installation may cause severe damage or injury. Read
the instructions carefully before installing the product.
This installation manual is intended for qualified personnel only.
ROGER TECHNOLOGY cannot be held responsible for any damage or injury due to
improper use or any use other the intended usage indicated in this manual.
Installation, electrical connections and adjustments must be performed by
qualified personnel, in accordance with best practices and in compliance with
applicable regulations. Before installing the product, make sure it is in
perfect condition.
Disconnect the mains electrical power before performing any work. Also
disconnect any buffer batteries used.
Only use original spare parts when repairing or replacing products. The
packaging materials (plastic, polystyrene, etc.) should not be discarded in
the environment or left within reach of children, as they are a potential
source of danger.
Product description
FIFTHY is a flashing warning lamp unit connectable to ROGER TECHNOLOGY control units.
Technical characteristics
| FIFTHY/24 FIFTHY/24/OR| FIFTHY/230 FIFTHY/230/OR
---|---|---
MAINS POWER VOLTAGE| 24 Vac/dc| 230 115 Vac Vac
MAX MAINS POWER ABSORPTION| 5,5 W| 4 W
OPERATING TEMPERATURE|
DEGREE OF PROTECTION| IP55| IP55
N.B.: the FIFTHY flashing lamp unit is assembled with thermosonic bonding technology to ensure an extremely high protection rating. In the event of breakage or malfunction, do not attempt to repair the flashing lamp unit and contact the customer support service or your dealer of choice.
Installation
- Ensure that the surface onto which the FIFTHY flashing lamp unit is to be installed is level, clean and not subject to vibration.
- Choose the mounting position: Figure 2 – top mounting position; Figure 3 – lateral mounting position.
- Drill the mounting surface with a maximum bit size of 6 mm.
- Assemble the flashing lamp unit with the cable housing base (A) at the bottom, as shown in fig. 2, or facing the wall, as shown in fig. 3.
- Ensure that the cable passage and the mounting base are sealed correctly if the mounting surface is not perfectly even.
- Make the electrical connections as shown in fig.4 (FIFTHY/230V – FIFTHY/230V/OR) or fig. 5-6 (FIFTHY/24V – FIFTHY/24V/OR).
- If the FIFTHY/230, FIFTHY/230/OR is used, protect the device with a F200mA (fast) fuse.
- Fasten the flashing lamp unit with the screws (B) and commercially available anchor plugs (not included).
Operation
Turn on the power supply.
Select the required flashing mode with the parameter 78 on the control unit
(except for H70/10CC – 11CC). This parameter is set as 78 00 by default (flash
frequency 1 Hz, 0.5 s on, 0.5 s off).
If required, set the pre-manoeuvre warning flash function with parameter A5
(except for H70/10CC – 11CC).
Disposal
**** The product may only be uninstalled by qualified technical personnel, following suitable procedures for removing the product correctly and safely. This product consists of numerous different materials. Some of these materials may be recycled, while others must be disposed of correctly at the specific recycling or waste management facilities indicated by local legislation applicable for this category of product. Do not dispose of this product as domestic refuse. Observe local legislation for differentiated refuse collection, or hand the product over to the vendor when purchasing an equivalent new product. Local legislation may envisage severe fines for the incorrect disposal of this product. Warning! Some parts of this product may contain substances that are harmful to the environment or dangerous and which may cause damage to the environment or health risks if disposed of incorrectly.
Additional information and contact details
ROGER TECHNOLOGY is the exclusive proprietor holder of all rights regarding
this publication. ROGER TECHNOLOGY reserves the right to implement any
modifications without prior notification. Copying, scanning or any alterations
to this document are prohibited without express prior authorised from by ROGER
TECHNOLOGY.
ROGER TECHNOLOGY CUSTOMER SERVICE:
business hours: Monday to Friday 08:00 to 12:00 – 13:30 to 17:30
Telephone no: +39 041 5937023
E-mail: service@rogertechnology.it
Skype: service_ rogertechnology
Declaration of Conformity
I the undersigned, as acting legal representative of the manufacturer Roger
Technology – Via Botticelli 8, 31021 Bonisiolo di Mogliano V.to (TV)
hereby DECLARE that the appliance described below:
Description: Flashing light Model: FIFTHY
Is conformant with the legal requisites of the following directives:
– 2014/30/EU; – 2014/35/EU; – 2011/65/CE and that all the standards and/or
technical requirements indicated as follows have been applied:
EN 61000-6-3; EN 61000-6-2
Last two figures of year in which marking was applied | 16.
Place: Mogliano ****to
Date: 20/12/2016
ROGER TECHNOLOGY
Via S. Botticelli 8
31021 Bonisiolo di Mogliano Veneto (TV)
ITALIA
P.IVA 01612340263
Tel. +39 041.5937023
Fax. +39 041.5937024
info@rogertechnology.com
www.rogertechnology.com
Documents / Resources
|
ROGER TECHNOLOGY IS158 24V Flashing
Light
[pdf] Instruction Manual
IS158, H70-10CC - H70-11CC, H70-104AC - 105APECD, IS158 24V Flashing Light,
24V Flashing Light, Flashing Light, Light
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>