Thermafloor HT1 Thermostat Touch Screen Simple Programming Instruction Manual

June 13, 2024
Thermafloor

HT1 Thermostat Touch
Screen Simple Programming
Instruction Manual
Thermafloor HT1 Thermostat Touch Screen Simple
Programming

| Touch Screen
---|---
| Simple Programming
| 5+2 / 7 Day Schedules
| User-friendly Menu
| Vertical / Horizontal models

INSTALLATION AND WIRING

Carefully separate the front half of the thermostat from the back plate by placing a small flat head terminal driver into the slots on the bottom face of the thermostat.
Carefully unplug the cable connector which is plugged into the front half of the thermostat.
Place the thermostat front half somewhere safe.
Follow the Wiring Diagram to do the wiring.
Screw the thermostat back plate on to the flush box Re-connect the thermostat cable and clip the two halves together.

DIMENSIONS

WIRING DIAGRAM

LCD SYMBOLS

| power on / off
---|---
M| mode button / menu button program button
| confirm the settings
| increase
| decrease
| auto mode
| manual mode
| key lock symbol
| the heating is turned on
P1,P2,P3,P4| the program numbers
SET| set temperature
Er| sensor not installed or error
A| air sensing mode
F| floor sensing mode
FA| air & floor sensing mode

TECHNICAL INFORMATION

SPECIFICATIONS|
---|---
SUPPLY  VOLTAGE| 5°C ~35°C
SWITCHING CAPABILITY| 230-240 VAC
TEMP RANGE(A)| 16A
FLOOR SENSOR
resistance default to 25°C| 10 Kohm.
IP RATING| 30
ORIENTATION| VERTICAL

SETTING THE OPERATING SCHEDULES

For 7 day programmable mode
Default Settings

| MONDAY  –  SUNDAY
---|---
PROGRAM| TIME| TEMP
P1| 7| 22°
P2| 9.3| 16°
P3| 16.3| 22°
P4| 22.3| 16°

Press and  M hold for 5 seconds,the day display will flash.
Use the arrows to select the day.
Press and hold the arrow for about 5 seconds to select all 7 days of the week, and to cancel press and and hold the arrow for about 5 seconds again.
Press M,the time for P1 will flash.
Use the arrows to adjust the time for P1.
Press M,the temperature for P1 will flash.
Use the arrows to adjust the temperature for P1.
Press M,the time for P2 will flash.
Use the arrows to adjust the time for P2.
Press ,M the temperature for P2 will flash.
Use the arrows to adjust the temperature for P2.
Repeat above steps for P3 and P4.

Note:
For Saturday and Sunday,
if you want to clear the time period of P2 and P3, press
Press again to cancel. during programing.

SETTING THE OPERATING SCHEDULES

For 5+2 day programmable mode(default)
Default Settings

|   MONDAY  –  FRIDAY| SATURDAY  – SUNDAY
---|---|---
PROGRAM| TIME| TEMP| TIME| TEMP
P1| 7| 22°C| 7| 22°C
P2| 9.3| 16°C| 9.3| 16°C
P3| 16.3| 22°C| 16.3| 22°C
P4| 22.3| 16°C| 22.3| 16°C

How to change the programs for Monday- Friday?
Press and hold for 5 seconds,the time for P1 will flash.

Use the arrows to adjust the time for P1.
Press M,the temperature for P1 will flash.
Use the arrows to adjust the temperature for P1.
Press M,the time for P2 will flash.
Use the arrows to adjust the time for P2.
Press M,the temperature for P2 will flash.
Use the arrows to adjust the temperature for P2.
Repeat above steps for P3 and P4.

How to change the programs for Saturday- Sunday?

When Monday- Friday programs has been set, continue to press M,the time for P1 will flash.
Use the arrows to adjust the time for P1.
Press M the temperature for P1 will flash.
Use the arrows to adjust the temperature for P1.
Press M,the time for P2 will flash.
Use the arrows to adjust the time for P2.
Press M,the temperature for P2 will flash.
Use the arrows to adjust the temperature for P2.
Repeat above steps for P3 and P4.

Note:

For Saturday and Sunday,
if you want to clear the time period of P2 and P3, press during programing.
Press again to cancel.

ADJUSTING THE PARAMETER VALUES

Turn the thermostat off by pressing After turning the thermostat off, press M The following menu will be displayed.
Use the arrows to adjust.
PressM to move to next menu.
Press to store and exit.

  1. Sensor Mode: A / AF / F
    A =Air Sensing Only(Has built in sensor)
    AF =Air & Floor sensing(Floor probe must be installed)
    F =Floor Sensing(Floor probe must be installed)

  2. Switching Differential
    1°C, 2°C….10°C ( 1°C by default)

  3. Air Temp Calibration
    -5°C ~ 5°C ( 0°C by default)

  4. Floor Temp Calibration
    -5°C ~ 5°C ( 0°C by default)

  5. Auto Exit Time
    5 ~ 30 seconds ( 20 seconds by default)

  6. Temperature Display Mode
    A : display air temperature only (by default)
    F : display floor temperature only
    AF : display air and floor temperature alternately

  7. Max Floor Temp Limit
    20°C ~ 40°C ( 40°C by default)

  8. Backlight Timer
    0,10,20,30,40,50,60, ON ( 20 seconds by default)

  9. Clock Format
    12 / 24 Hour clcok format ( 24 Hour clock by default)

  10. Frost protection
    00 ,01 (default 00=not activated, 01=activated)

  11. 5+2 / 7 Day Program Option
    01 = 5+2 Day Program ,02= 7 Day Program (default 01)

SETTING THE TIME AND DAY

Press , the time display will flash.
Use the arrows to adjust.
Press , the day display will flash.
Use the arrows to adjust.
Now press to store and exit.

AUTO / MANUAL MODE

Press M to select Auto or Manual mode.

Auto mode:
Manual mode:

In Manual mode, press the arrows to set the desired temperature.
In Auto mode, press the ****arrows will override the current programed temperature unitl the next programmed period.

LOCK THE KEYPAD

To lock the keypad, press and hold for 5 seconds, you will see a lock symbol . To unlock, repeat the steps above and the lock symbol will disappear.

TEMPORARY TEMPERATURE OVERRIDE

In Auto mode, press the ****arrows, the temperature display will start to flash.
Use the arrows to adjust the temperature.
Press to confirm.

Now you will see “ O/RIDE ” below the temperature display. Your thermostat will maintain the new set temperature until the next programmed period. To cancel the override setting, press and hold M for about 5 seconds.