EVA LOGIK ZWS713 Z-wave 3 in 1 Sensor D W Temp and Hum Sensor Instruction Manual
- June 13, 2024
- EVA LOGIK
Table of Contents
EVA LOGIK ZWS713 Z-wave 3 in 1 Sensor D W Temp and Hum Sensor Instruction
Manual
Specification
Battery: CR2450*1
Frequency: 908.42MHz
Temperature Range: 32°F~104°F
Indoor use in dry location
-
Battery position
-
LED Indicator:
ADD/REMOVE: Blue LED flashing
Reset :LED flashing and stay up 3S -
Program buttom:
Press 3x: Add/Remove Z-Wave network
Press 5x: Wake-up device Note:When you need to set param,the device must wake up statu
Reset: Click the button 2 times quickly while stay at least 10 seconds -
Open and access the battery
The device contains two Multilevel sensors with the following accuracy
measures:
Relative Humidity: precision ± 3% RH (max), range 0 to 100% RH
Temperature: precision ±0.4 °C (max), range -25 to 125 °C
Installation
- You can choose mount it on any type of clean flat surface on D/W.
- Use the supplied adhesive tape to attach magnetic base to the D/W.
- Install in your electrical switch box or mount anywhere on a wall with just adhesive tape
- Power by battery,no need wires needed.Note the ± direction of the battery
- Control other Z-wave devices and enable scenes with a click of a button
Z-wave Control
Adding Device To your hub and Z-Wave Network for QR code
- Choose your hub into and scan the QR code with your phone’s camera and add to Smartstar
Note: DSK Code can be foucd on packaging. Do not remove or damage them.
Wake-up mode
The sensor’s wake-up interval is set to 12 hours by default to save battery
life. You can change the wake-up interval using your controller’s advanced
settings if available.
Manual wake -up
- Press 5x the Z-wave buttom to wake up the device .The LED indicator flashing stay up 1s. You may need to wake up the sensor manually IF: 1. It doesn’t fully configure during set-up (values are not displayed or errors pop up in your hub’s interface).
- You change advanced settings for the sensor and hope them will be updated.
To add the device
- Follow the instructions for your Z-Wave certified controller to adding device from the Z-Wave network.
- Once the controller is preparing add your device, press the program button 3 times quickly.
To remove the device
- Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.
- Once the controller is preparing remove your device, press the program button 3 times quickly
Factory reset
Manual: Click the button 2 times quickly while stay at least 10 seconds
.LED flashing and while stay up 3S.
Note:
Install the custom device handler to access the right functions if you’re
using the SmartThings hub. Please visit our website: www.nie-
tech.com or email us: ask@nie-tech.com
Parameter Settings
Parameter 1 Battery report threshold
Use this parameter to set battery level change to be reported by the sensor.
(DEFAULT): 10%
Parameter 2 Low Battery alarm report
Use this parameter to set battery level for sending low battery reports.
size=1 byte Available range : 5%-20%
(DEFAULT) : 5%
Parameter 3 Parameter defines state of the sensor when the magnet closes the reed size=1 byte Available settings:
Decide which status should the sensor report to the hub when the magnet
touched the sensor
0 – door/window closed (DEFAULT)
1 – door/window opened
Parameter 4 Delay in seconds with ON command report ( door closed ) Use this
to set the door close delay reporting time
size=2 bytes Available settings: 0 (DEFAULT) – 3600s
Parameter 5 Delay in seconds with OFF command report ( door open ) Use this to
set the door open delay reporting time
size=2 bytes Available settings: 0 (DEFAULT)- 3600s
Parameter 6 Minimum Temperature change to report Use this to set temperature
change to be reported by the sensor. size=1 byte Available range : 5-50
(0.1°C step)
Value 5 = 0.5 °C
…
Value 10 = 1.0 °C(DEFAULT)
Value 50 = 5.0°C
Parameter 7 Minimum humidity change to report Use this to set humidity
percentage change to be reported by the sensor
size=1 byte Available range : 5-20
(DEFAULT): 10(10%)
Parameter 8 Temperature Upper Watermark value If the measured temperature
surpasses this watermark a BASIC command is sent into Association Group 3
size=1 bytes Use this to set Temperature Upper Watermark value to be reported
by
the sensor
Value = 0: disabled (DEFAULT)
Value = 1~50°C
Parameter 9 Temperature Upper Notification and Association Group Control
Size=1byte Use this to set Temperature Upper Notification report and
Association Group 3 Control function
Value = 0: disable notification and association group basic set.
Value = 1: only notification report to lifeline group
Value = 2: only basic set on to association group 3
Value = 3: notification to lifeline and basic set on to association group
3
Value = 4: only basic set off to association group 3
Value = 5: notification to lifeline and basic off to association group 3
Value = 6: basic set on and off to association group 3
Value = 7: notification to lifeline and basic set on and off to
association group
3.(DEFAULT)
Parameter 10 Temperature Lower Watermark value
If the measured temperature surpasses this watermark a BASIC command is sent
into Association Group 4
size=1 bytes Use this to set Temperature Lower Watermark value to be reported
by the sensor.
Value = 0: disabled (DEFAULT)
Value = 1~50°C
Parameter 11 Temperature Lower Notification and Association Group Control
Size=1byte Use this to set Temperature Lower Notification report and
Association Group 4 Control function
Value = 0: disable notification and association group basic set.
Value = 1 : only notification report to lifeline group
Value = 2: only basic set on to association group 4
Value = 3: notification to lifeline and basic set on to association group
4
Value = 4: only basic set off to association group 4
Value = 5: notification to lifeline and basic off to association group 4
Value = 6: basic set on and off to association group 4
Value = 7: notification to lifeline and basic set on and off to
association group 4.
(DEFAULT)
Parameter 12 Humidity Upper Watermark value
If the measured temperature surpasses this watermark a BASIC command is sent
into Association Group 5 size=1 byte Use this to set Humidity Upper Watermark
value to be reported by the sensor.
Value = 0: disabled (DEFAULT)
Value = 1~100%
Parameter 13 Humidity Upper Notification and Association Group Control
Size=1byte Use this to set Humidity Upper Notification report and Association
Group 5 Control function
Value = 0: disable notification and association group basic set.
Value = 1: only notification report to lifeline group
Value = 2 : only basic set on to association group 5
Value = 3: notification to lifeline and basic set on to association group
5
Value = 4: only basic set off to association group 5
Value = 5: notification to lifeline and basic off to association group 5
Value = 6: basic set on and off to association group 5
Value = 7: notification to lifeline and basic set on and off to
association group 5.
(DEFAULT)
Parameter 14 Humidity Lower Watermark value
If the measured temperature surpasses this watermark a BASIC command is sent
into Association Group 6
size=1 byte Use this to set Humidity Lower Watermark value to be reported by
the sensor.
Value = 0: disabled (DEFAULT)
Value = 1~100%
Parameter 15 Humidity Lower Notification and Association Group Control
Size=1byte Use this to set Humidity Lower Notification report and Association
Group 6 Control function
Value = 0: disable notification and association group basic set.
Value = 1: only notification report to lifeline group
Value = 2: only basic set on to association group 6
Value = 3 : notification to lifeline and basic set on to association
group 6
Value = 4: only basic set off to association group 6
Value = 5: notification to lifeline and basic off to association group 65
Value = 6: basic set on and off to association group 6
Value = 7: notification to lifeline and basic set on and off to
association group 6.
(DEFAULT
Parameter 16 Switch the unit of Temperature report
size=1 byte Use this parameter to switch from Fahrenheit to Celsius scale. 0 –
Celsius
1 – Fahrenheit (DEFAULT)
Parameter 17 Offset value for temperature
Use this to set Temperature error value,
size=1 byte Range = -100~100 (0.1°C step)
-100 : -10°C
…
0: 0°C(DEFAULT)
…
100:+10°C
Parameter 18 Offset value for humidity
Use this to set Humidity error value
size=1 byte Range = -20~20 (1% step)
-20 : -20%
…
0: 0 (DEFAULT)
…
20:+20%
Parameter 19 Association Group 2 Setting
Size = 1byte Use this to set Association group 2 function
Value = 0: Disable completely
Value = 1 : Send Basic SET 0xFF when Magnet is away, and send Basic SET
0x00 when Magnet is near.(DEFAULT)
Value = 2: Send Basic SET 0x00 when Magnet is away, and send Basic SET
0xFF when Magnet is near.
Value = 3: Only send Basic SET 0xFF when Magnet is away.
Value = 4: Only send Basic SET 0x00 when Magnet is near.
Value = 5 : Only send Basic SET 0x00 when Magnet is away.
Value = 6 : Only send Basic SET 0xFF when Magnet is near.
Association Group:
- Support group number: 6
- Each group max. Support 5 devices
- Group 1 Lifeline
- Group 2 Door/Window sensor change send Basic Set Command
- Group 3 High Temperature Send Basic Set Command
- Group 4 Low Temperature Send Basic Set Command
- Group 5 High Humidity Send Basic Set Command
- Group 6 Low Humidity Send Basic Set Command
Command Class
Generic Device Class : 0x07 – GENERIC_TYPE_SENSOR_NOTIFICATION
Specific Device Class: 0x01 – SPECIFIC_TYPE_NOTIFICATION_SENSOR
Command Classes:
- 0x5E – COMMAND_CLASS_ZWAVEPLUS_INFO
- 0x85 – COMMAND_CLASS_ASSOCIATION
- 0x8E – COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
- 0x59 – COMMAND_CLASS_ASSOCIATION_GRP_INFO
- 0x31 – COMMAND_CLASS_SENSOR_MULTILEVEL
- 0x55 – COMMAND_CLASS_TRANSPORT_SERVICE
- 0x86 – COMMAND_CLASS_VERSION
- 0x72 – COMMAND_CLASS_MANUFACTURER_SPECIFIC
- 0x5A – COMMAND_CLASS_DEVICE_RESET_LOCALLY
- 0x73 – COMMAND_CLASS_POWERLEVEL
- 0x80 – COMMAND_CLASS_BATTERY
- 0x9F – COMMAND_CLASS_SECURITY_2
- 0x71 – COMMAND_CLASS_NOTIFICATION
- 0x87 – COMMAND_CLASS_INDICATOR
- 0x30 – COMMAND_CLASS_SENSOR_BINARY
- 0x70 – COMMAND_CLASS_CONFIGURATION
- 0x84 – COMMAND_CLASS_WAKE_UP
- 0x6C – COMMAND_CLASS_SUPERVISION
- 0x7A – COMMAND_CLASS_FIRMWARE_UPDATE_MD
Warranty
Our Products warrants this product to be free from manufacturing defects for a period of one year from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives you specific rights, and you may also have other rights which vary from state to state.
FCC / IC
This device complies with part 15 of the FCC and Industry Canada license- exempt RSS standard(s). Operation is subjected to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC NOTE
The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help
NOTE
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following
Important note:
To comply with the FCC RF exposure compliance requirements, no change to
the antenna or the device is permitted. Any change to the antenna or the
device could result in the device exceeding the RF exposure requirements and
void user’s authority to operate the device.