TROTEC BA16 Impeller Anemometer Instruction Manual

June 13, 2024
TROTEC

TROTEC-LOGO

TROTEC BA16 Impeller Anemometer

TROTEC-BA16-Impeller-Anemometer-FIG- \(2\)

Product Information

  • Product Name: BA16 Vane Anemometer
  • Model Number: BA16
  • Language: English (EN)
  • Manufacturer: Trotec
  • Product Type: Vane Anemometer

Product Usage Instructions

Safety Precautions:

  • Read the manual carefully before using the device.
  • Store the manual in the immediate vicinity of the device or its site of use.
  • Only use the device for measurements of air velocity, air temperature, and volumetric flow within the specified measuring range.
  • Do not use the device in potentially explosive atmospheres or for measurements in liquids or at live parts.
  • Do not make any unauthorized changes, modifications, or alterations to the device.

Intended Use:

  • Use the device for measurements of air velocity, air temperature, and volumetric flow within the specified technical data range.
  • Only use accessories and spare parts approved by Trotec.

Foreseeable Misuse:

  • Do not use the device in potentially explosive atmospheres.
  • Avoid using the device for measurements in liquids or at live parts.

Residual Risks:

  • Avoid immersing the device and accessories in water to prevent short-circuits.
  • Work on the electrical components should only be carried out by an authorized specialist company.
  • Ensure that the packaging is not left around, as it may pose a suffocation risk to children.
  • Do not allow children to handle the device, as it is not a toy.
  • Ensure that only trained personnel use the device in a professional and proper manner to avoid potential dangers.
  • Keep a sufficient distance from heat sources while using the device.

Transport and Storage:
Follow the guidelines provided in the manual for the transport and storage of the device.

Operation:
Refer to the manual for detailed instructions on operating the vane anemometer.

Maintenance and Repair:
Follow the maintenance and repair instructions provided in the manual.

Errors and Faults:
If any errors or faults occur, refer to the manual for troubleshooting steps or contact an authorized specialist company for assistance.

Disposal:
Follow the proper disposal guidelines as mentioned in the manual or local regulations.
For further information, you can download the current version of the operating manual and the EU declaration of conformity from here.

Notes regarding the operating

  • Warning of electrical voltage
    This symbol indicates dangers to the life and health of persons due to electrical voltage.

  • Warning
    This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.

  • Caution
    This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.

  • Note
    This signal word indicates important information (e.g. material damage), but does not indicate hazards.

  • Info
    Information marked with this symbol helps you to carry out your tasks quickly and safely.

  • Follow the manual
    Information marked with this symbol indicates that the operating manual must be observed.

You can download the current version of the operating manual and the EU declaration of conformity via the following link

https://hub.trotec.com/?id=40844

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use.
Warning
Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference.

  • Do not use the device in potentially explosive rooms or areas and do not install it there.
  • Do not use the device in aggressive atmosphere.
  • Do not immerse the device in water. Do not allow liquids to penetrate into the device.
  • The device may only be used in dry surroundings and must not be used in the rain or at a relative humidity exceeding the operating conditions.
  • Protect the device from permanent direct sunlight.
  • Do not expose the device to strong vibrations.
  • Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.
  • Do not open the device.
  • Never charge batteries that cannot be recharged.
  • Different types of batteries and new and used batteries must not be used together.
  • Insert the batteries into the battery compartment according to the correct polarity.
  • Remove discharged batteries from the device. Batteries contain materials hazardous to the environment. Dispose of the batteries according to the national regulations.
  • Remove the batteries from the device if you will not be using the device for a longer period of time.
  • Never short-circuit the supply terminal in the battery compartment!
  • Do not swallow batteries! If a battery is swallowed, it can cause severe internal burns within 2 hours! These burns can lead to death!
  • If you think batteries might have been swallowed or otherwise entered the body, seek medical attention immediately!
  • Keep new and used batteries and an open battery compartment away from children.
  • Observe the storage and operating conditions (see Technical data).

Intended use

  • Only use the device for measurements of air velocity, air temperature and volumetric flow within the measuring range specified in the technical data. Observe and comply with the technical data.
  • To use the device for its intended use, only use accessories and spare parts which have been approved by Trotec.

Foreseeable misuse

  • Do not use the device in potentially explosive atmospheres, for measurements in liquids or at live parts.
  • Any unauthorised changes, modifications or alterations to the device are forbidden.

Personnel qualifications
People who use this device must: have read and understood the operating manual, especially the Safety chapter.

Residual risks

  • Warning of electrical voltage
  • There is a risk of a short-circuit due to liquids penetrating the housing!
  • Do not immerse the device and the accessories in water. Make sure that no water or other liquids can enter the housing.

Warning of electrical voltage
Work on the electrical components must only be carried out by an authorised specialist company!

Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may use it as a dangerous toy.

Warning
The device is not a toy and does not belong in the hands of children.

Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!

Caution
Keep a sufficient distance from heat sources.

Note
To prevent damages to the device, do not expose it to extreme temperatures, extreme humidity or moisture.

Note
Do not use abrasive cleaners or solvents to clean the device.

Information about the device

Device description
The anemometer BA16 can simultaneously measure the temperature and air velocity.
Temperature measuring is effected by means of an integrated thermistor in °C or °F.

The air velocity can be indicated in the following units:

  • m/s
  • km/h
  • ft/min
  • mph
  • knots
  • m3/min (CMM)

The sensor is located at a so-called gooseneck probe, with that it is able to measure even in poorly accessible locations.
Further available for the assessment of the measurements are a Hold and a Max/Min function.
The display illumination can be switched on as needed. When not in use, an automatic switch-off saves the battery.

Device depiction

TROTEC-BA16-Impeller-Anemometer-FIG-
\(4\)

No. Designation
1 Measuring sensor with flexible holder
2 Display
3 Operating elements
4 Battery compartment with cover

Operating elements

No. Designation
5 HOLD /light button
6 UNITS button
7 MAX/MIN button
8 Power button

DisplayTROTEC-BA16-Impeller-Anemometer-FIG- \(6\)

No. Designation
9 Indication of the measured temperature value
10 Temperature unit indication
11 AREA indication
12 Indication of the units for velocity and volumetric flow
13 Indication of the measured value x 100
14 Indication of the measured value x 10
15 HOLD indication
16 AVG indication
17 MIN indication
18 MAX indication
19 Indication of the measured velocity value
20 Battery status indication
21 VEL indication
22 RECORD indication
23 RECALL indication

Technical data

Parameter Value
Model BA16

Temperature
Measuring range| -10 °C to 60 °C

(14 °F to 140 °F)

Accuracy| ± 1.5 °C (3.0 °F)
Measuring range resolution| ± 0.1 °C (± 0.1 °F)
Air velocity
Measuring range| 1.00 m/s to 30.00 m/s 196 ft/min to 5900 ft/min

3.6 km/h to 108.0 km/h

2.2 mph to 67.0 mph

1.9 kn to 58.0 kn

Accuracy| ± 3 % ± 0.20 m/s

± 3 % ± 40 ft/min

± 3 % ± 0.8 km/h

± 3 % ± 0.4 mph

± 3 % ± 0.4 kn

Measuring range resolution| 0.01 m/s 1 ft/min

0.1 km/h

0.1 mph

0.1 kn

General technical data
Storage temperature| -20 °C to 60 °C (-4 °F to 140 °F)

with < 80 % RH (non-condensing)

Operating temperature| 0 °C to 50 °C (32 °F to 122 °F) with

< 80 % RH

(non-condensing)

Power supply| 1 x 9 V battery
Device switch-off| after approx. 15 minutes of non-use
Type of protection| IP40
Weight| approx. 263 g (incl. battery)
Dimensions (H x W x D) Length of the gooseneck probe| 162 mm x 54 mm x 32 mm

360 mm

Scope of delivery

  • 1 x Device BA16
  • 1 x 9 V battery
  • 1 x Transport case
  • 1 x Quick guide

Transport and storage

Note
If you store or transport the device improperly, the device may be damaged.
Note the information regarding the transport and storage of the device.

Transport
For transporting the device, use the transport case included in the scope of delivery in order to protect the device from external influences.

Storage
When the device is not being used, observe the following storage conditions:

  • dry and protected from frost and heat
  • protected from dust and direct sunlight
  • For storing the device, use the transport case included in the scope of delivery in order to protect the device from external influences.
  • the storage temperature complies with the values specified in the Technical data

Inserting the battery
Make sure that the surface of the device is dry and the device is switched off TROTEC-BA16-Impeller-Anemometer-FIG- \(7\)

  1. Remove the cover (24) from the device.
  2. Use the battery clip (25) to connect the new battery with correct polarity.
  3. Slide the cover (24) back on the device

Switch-on and measurements

  1. Press the Power button (8) for approx. 3 seconds.
  2. The display will be switched on and the device ready for operation.
  3. Hold the measuring sensor (1) into the area where the measurement is to be performed. Ideally, the vane is aligned precisely to the flow direction.
  4. The measured values for temperature and air velocity are displayed in real time

Note:
Note that moving from a cold area to a warm area can lead to condensation forming on the device’s circuit board. This physical and unavoidable effect can falsify the measurement. In this case, the display shows either no measured values or they are incorrect. Wait a few minutes until the device has become adjusted to the changed conditions before carrying out a measurement

Switching the display illumination on and off

  1. Press the HOLD/lamp button (5) for approx. 2 seconds.
  2. The display illumination goes on.
  3. Press the HOLD/lamp button (5) again for approx. 2 seconds.
  4. The display illumination switches off.

Setting the temperature unit

  1. Press the UNITS button (6) for approx. 3 seconds.
  2. Depending on the setting the temperature indication (10) changes to °C or °F.

Setting the air velocity unit

  1. Press the UNITS button (6) until the desired unit is displayed

Entering the cross-sectional area for volumetric flow measurement
In order to obtain a precise indication of the volumetric flow measurement (CMM), the cross-sectional area of the opening to be tested must be entered prior to measuring. To do so, use the function AREA. The unit of the cross- sectional area is to be specified in m². For entering the value of the cross- sectional area please proceed as follows:

  1. Switch the device off.
  2. Press and hold the HOLD/lamp button (5) while switching the device back on.
  3. The indication SET AREA will be appear on the display.
  4. Press the MAX / MIN button (7).
  5. The decimal point will move.
  6. Press the HOLD/lamp button (5).
  7. You can alternate between the digits, the selected number flashes.
  8. Press the UNITS button (6).
  9. The value of the selected digit changes.
  10. Repeat the steps 4. and 5. until the value is set as desired.
  11. Switch the device off.
  12. The set value of the cross-sectional area will be used for the calculation of the volumetric flow after the next switch-on.

Indication of minimum and maximum values

  1. Press the MAX / MIN button (7).
  2. The RECORD indication (22) appears on the display.
  3. Press the MAX/MIN button (7) to switch between the maximum and minimum value.
  4. MAX (18) appears on the display.
  5. Actuating the MAX / MIN button (7) starts a new measurement. The value now appearing on the display is the reference value.
  6. MAX function: The maximum value of the newly started measurement interval is displayed. Values smaller than the one displayed will not be indicated.
  7. Press the MAX/MIN button (7) again.
  8. MIN (17) appears on the display.
  9. Actuating the MAX / MIN button (7) starts a new measurement. The value now appearing on the display is the reference value.
  10. MIN function: The minimum value of the newly started measurement interval is displayed. Values exceeding the one displayed will not be indicated.
  11. Press the MAX / MIN button (7) for approx. 3 seconds to terminate the function.
  12. The values will be deleted from the buffer memory

Using the HOLD function

  1. Press the HOLD/lamp button (5).
  2. The current value will be indicated on the display.
  3. Press the HOLD/lamp button (5). again.
  4. The display again indicates the current measured value.

Disabling automatic switch-off
As standard, the automatic switch-off function is activated. This results in the device switching off automatically after 15 minutes of non-use. Please proceed as follows to deactivate the automatic switch-off function:
The device is switched off.

  1. Additionally press the UNITS button (6) when switching the device on.
  2. The indication disAPO appears on the display.
  3. Automatic switch-off is deactivated.

Info
Note that the automatic switch-off function is activated upon the next switch- on. If you do not like to use the function, deactivate the automatic switch- off function as described.

Switching the device off

  1. Briefly press the Power button (8).
  2. The device will be switched off.
  3. The saved measured maximum and minimum values are reset

Maintenance and repair

  • Battery change
    A battery change is required when the battery status indication (20) lights up or the device can no longer be switched on (see chapter Inserting the battery).

  • Cleaning
    Clean the device with a soft, damp and lint-free cloth. Make sure that no moisture enters the housing. Do not use any sprays, solvents, alcohol-based cleaning agents or abrasive cleaners, but only clean water to moisten the cloth.

  • Repair
    Do not modify the device or install any spare parts. For repairs or device testing, contact the manufacturer

Errors and faults

The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list

Fault Cause Remedy
The device can no longer be switched on. The battery is dead. Insert a new

battery (see chapter Operation).
The device indicates implausible values of the volumetric flow measurement.| The cross-sectional area of the opening has not been entered (correctly).| Determine and enter the cross-sectional area of the opening (in m²) (see chapter Operation).

Disposal

  • Always dispose of packing materials in an environmentally friendly manner and in accordance with the applicable local disposal regulations.
  • The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. You can also find out about other return options that apply to many EU countries on the website https://hub.trotec.com/?id=45090.
  • Otherwise, please contact an official recycling center for electronic and electrical equipment authorized for your country.
  • The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling, and other forms of recovery of waste equipment as well as to prevent negative effects on the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.
  • In the European Union, batteries and accumulators must not be treated as domestic waste but must be disposed of professionally in accordance with Directive 2006/66/EC of the European Parliament and of the Council of 6 September 2006 on batteries and accumulators. Please dispose of batteries and accumulators according to the relevant legal requirements.

Only for United Kingdom
According to Waste Electrical and Electronic Equipment Regulations 2013 (SI 2013/3113) (as amended) and the Waste Batteries and Accumulators Regulations 2009 (SI 2009/890) (as amended), devices that are no longer usable must be collected separately and disposed of in an environmentally friendly manner.

Trotec GmbHGrebbener Str. 7 D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
info@trotec.com
www.trotec.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals