CLIMATERIGHT CR12000SACH Mini Split Air Conditioner And Heater Owner’s Manual

June 13, 2024
ClimateRight

CLIMATERIGHT-logo

CLIMATERIGHT CR12000SACH Mini Split Air Conditioner And Heater

CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-Heater-
product

Product Information

This product is the CLIMATERIGHT CR12000SACH Mini-Split Air Conditioner and Heater. It is designed for household use and provides both cooling and heating functions. The product comes with an evaporator (indoor unit), a condenser (outdoor unit), and a remote control. For more information, please refer to the owner’s manual and installation guide.

Product Usage Instructions

  1. Before assembly and use, carefully read and follow all safety rules and instructions provided in the manual.
  2. Ensure proper ventilation and avoid anything that may obstruct the operation of the front of the indoor unit.
  3. Do not install the unit near sources of heat or direct sunlight.
  4. Ensure there is enough space between the unit and the walls.
  5. Reduce the bending of the piping line as much as possible to avoid reduced performance of the unit.
  6. Install the unit on a sturdy base or frame that can withstand the machine weight and will avoid causing vibration and noise. Pay attention to the drainage of the condensed water from the base plate during installation.
  7. Refer to the remote controller section in the manual for instructions on how to use it.

Please note that this is a summary of the product usage instructions. For detailed instructions, please refer to the owner’s manual and installation guide provided with the product.

INTRODUCTION

CLIMATERIGHT CR12000SACH Mini-Split Air Conditioner and Heater Thank you for choosing Climate Right. This owner’s manual will provide you with valuable information necessary for the proper care, installation, and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Climate Right Mini-Split Air Conditioner and Heater.

For your records, please attach a copy of your sales receipt to this manual.
Also, write the store name/location, date purchased, and serial number below

PACKAGE CONTENTS

CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-01

CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-02

SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS FOR USING YOUR Mini Split Air Conditioner and Heater

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:

  • Fully assemble before operating.
  • Do not repair or modify the unit unless All other repairs should be completed by
  • he plug for this unit is polarized with one blade wider than the other. Do not force the plug into an electrical outlet. Do not alter the plug in any way. If the plug dose not
  • Do not use if the power cord or plug is damaged or the connection to the wall outlet is loose.
  • Do not damage, break, forcefully bend, pull, twist, bundle, coat, pinch, or place heavy objects on the power cord.
  • Periodically remove dust from the powerplay.
  • If the power plug is damaged, it must be technician.
  • Remove the power plug from the outlet before cleaning the unit. When removing the power plug, grasp by holding the plug itself, never hold by the cord.
  • Remove the power plug from the outlet when not in use.
  • Do not handle the power plug with wet hands.
  • Do not operate the unit when using indoor smoke-generating insecticides.
  • Do not clean unit with benzene or paint thinner. Do not spray insecticides on the unit.
  • Do not use the unit where it is humid or where the unit may become wet, such as in a bathroom. objects into the air intake or outlet. gases. Do not use near cigarettes, incense, or other spark-creating items.
  • Unit will not remove radon or carbon monoxide emitted from heating appliances or other sources.
  • Do not use near hot objects, such as
  • Do not use where the unit may come into contact with steam.
  • Do not use the unit on its side.
  • Do not install where the air outlet will
  • Keep away from products that generate oily residue.
  • Keep children and pets away from the product.
  • Always unplug the unit before cleaning or servicing.
  • Use of an extension cord is not recommended as it could prevent the unit from operating normally and could potentially pose a fire and safety risk. It is recommended that unit is located near a 3-prong 115V GFCI outlet. If one is not available, a qualified electrician should install one.

PACKAGE CONTENTS

CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-03

USERS GUIDE

This air conditioner is designed to create a comfortable climate for individuals in the affected room. It can cool and dehumidify the air completely automatically and also provide heat using a heat pump. Air pulled by the fan enters through the grill of the front panel and passes through the filter, which traps dust inside. Air is then sent to the heat exchanger and is cooled, dehumidified, or re-heated by the heat exchanger. Heat removed from the air is then sent outside. When the cycle is finished, the fan sends the freshened air back into the room. The direction of the air outlet is regulated by the flaps, which are motorized to move up and down as well as side to side by the vertical directors.

Auto Mode: The auto mode allows the air conditioner to maintain a pre- programmed temperature of 76 degrees in the affected room. While in this mode, the air conditioner will automatically select the appropriate fan speed and mode of operation, COOL or HEAT, to maintain that temperature.

Cooling Mode: The cooling mode allows the air conditioner to cool the room while dehumidifying the air at the same time. To activate the cooling mode, press the on the remote to set the system to a temperature lower than that of the room.
Dry Mode : The system can be set to run in DRY mode, reducing the humidity of the air in the room for increased comfort. To activate the dry mode, press the MODE

The air conditioner will automatically cycle between cooling and fan only modes to dehumidify the air.
Heating Mode: The heating mode allows the air conditioner to produce hot air using a heat pump. To activate the heating mode, press the MODE button on the remote symbol is pointing to HEAT on the remote’s display. The desired the system to a temperature higher than that of the room.

Fan Mode: The system can be set to run in FAN mode, providing ventilation only. To activate the fan mode, press the MODE button on the remote until the symbol is ****pointing to FAN on the remote’s display. Pressing the FAN SPEED button while in this mode changes the fan speed to LOW, MEDIUM, HIGH, and AUTO. The remote control will automatically save the last fan speed setting from the previous time the system was in operation.

Sleep Function: This system can also function in SLEEP mode, which will automatically adjust the temperature to maximize comfort during night time sleep. To put the air conditioner into SLEEP mode, press the SLEEP button on the remote until the symbol is pointing to SLEEP on the remote’s display. If the system is set to run using the cooling or dry modes, the set temperature will automatically be raised by 1 degree every 60 minutes for a total of 2 degrees during the first 2 hours. If the system is set to run using the heat mode, the set temperature will be gradually lowered by 2 degrees during the first 2 hours. After 10 hours operating in the SLEEP mode, the system will switch off automatically.

USERS GUIDE
Timer Function: The TIMER function allows the system to automatically switch on and off based on your settings. To set timed start, the system should be turned off. Press TIMER, set the desired temperature by the pressing the or buttons. Press TIMER again and set the   amount of time, again using the or buttons. Press TIMER again until the display shows the amount of time entered until the programmed TIMER start. The timer is now set. Before setting the timer you will need to select the mode of operation, the fan speed, and desired temperature then turn the system off using the ON/OFF button. To cancel a timed start that has already been entered, press the TIMER button again.

To set a timed stop, the system should be turned on. Press the TIMER button, then use the or buttons to set the amount of time desired until the system will automatically stop. As you do this, the display will show the amount of time the system can be programmed to stop after. To cancel a timed stop that has already been entered, press the TIMER button again.

If the system loses power or is turned off, it will be necessary to reset a timed a timed start or timed stop again using the above instructions. Both timer functions can only be programmed in half hour increments.

CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-04

PRE SET-UP INSTRUCTIONS

ASSEMBLY Tools needed for installation

  • Stud Finder Pencil
  • Drill with Drill Bits
  • Tape Measure
  • 6 – 2” Wood Screws Step Ladder
  • Level
  • Wall Clamps
  • 2-¾” hole saw

Ensure proper ventilation and avoid anything that may obstruct operation the front of the indoor unit.

Do not install the unit near the following places.

  • Flammable gases
  • Hot flammable items such as a spark or hot oil
  • Poisonous or sultry gases are generated
  • Seaside district exposed to sea breezes
  • Air conditioner body and remote controller must be (39-3/4”) or more away from a TV or a radio
  • Drain the dehumidified water from the indoor unit

Do not install the unit near the following places
When installing the unit, choose a place which can stand the weight of the unit and does not increase the operation noise or vibration. Avoid areas where there may be vibration in the house, and affix the unit by inserting / attaching vibration-proof pads between the unit and fittings.

  • Avoid leaving items near the outlet and inlet of the outdoor unit. These can cause malfunction or increase operation noise.
  • Consult your ClimateRight® Customer Service Representative if you continue to hear irregular sounds during operation

PRE SET-UP INSTRUCTIONS

Ensure there is enough space between the unit and the walls.

CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-07

  • Reduce the bending of the piping line as much as possible to avoid reduced performance of the unit (Fig. 1:1).
  • Install the unit on a sturdy base or frame that can withstand the machine weight and will avoid causing vibration and noise.
  • Install the unit where it will not be exposed to direct rain or sunshine and is well ventilated.
  • Do not install the unit on non-metal frame.
  • Pay attention to the drainage of the condensed water from the base plate during operation.
  • Avoid positioning air outlet directly against the wind

Outdoor Space Requirements

CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-08

  • * Avoid leaving items near the outlet and inlet of the outdoor unit. These can cause malfunction or increase operation noise.
    • Consult your ClimateRight® Customer Service Representative if you continue to hear irregular sounds during operation

POWER CORD ASSEMBLY

  1. Gather the tools and parts listed below and prepare a workspace where small items, such as screws and other small parts, can be safely set aside and not lost.
    Required tools
  • Hammer
  • Punch or Chisel
  • Phillips Screw Driver (#2)
  • Wire strippers/cutters

CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-09 Required Parts

  • Power Cord

  • Power Plug

  • Power Cord Connector

  • On the rear of the power plug, both screws should be loosened to allow the power cable to be inserted as shown in step 4.

CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-010

  1. Remove the end of the power plug by loosening the 3 screws indicated.
  2. Thread the end of the cable through the rear of the power plug as shown. Ensure the end without the spade terminals is used in this step. CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-Heater-011POWER CORD ASSEMBLY
  3. Using wire cutters, clip the white, black, and green wires within approximately 1” of the black insulation as shown. Using the wire stripper, remove approximately 1/2” of insulation off the end of each of the 3 wires clipped. Twist the copper conductor threads after stripping the insulation, to minimize fraying. CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-Heater-012
  4. Align the wires and secure the copper conductors into the plug terminals as shown. Insert the copper as much as possible into the terminals without clamping the insulation. Ensure the green wire is connected to the terminal with the green screw, the white wire to the terminal with the silver screw, and the black wire to the terminal with the brass screw. Tighten all 3 terminal screws and make sure all wires are secure.
  5. Slide the rear piece of the power plug forward on the wire and reattach with 3 screws on front. The front and rear pieces must be aligned for the screws to thread properly, note that there are two screws closer together when mating the two pieces.
  6. Tighten the two screws on the rear of the power plug to complete the attachment of the plug to the power cord. Do not connect to power outlet until the rest of the steps have been completed.

POWER CORD ASSEMBLY

Remove screws and plastic washers from side panels A, B, and C; each panel has 3 screws and 3 washers as indicated. Set both the screws, plastic washers, and panels aside until later. CLIMATERIGHT-CR12000SACH-Mini Split-Air-
Conditioner-And-Heater-014

Place Panel B on a sturdy surface then use a hammer and punch to break out the right circular tab as shown. This is where the power cord will be passed through and attached to the enclosure.

Unscrew the plastic nut from the enclosure connector as shown. Then set aside for later. Thread the end of the power cable through the enclosure connector as shown. The black insulator should be flush with the end of the connector. CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-015

POWER CORD ASSEMBLY

Thread the 3 wires from the power cable and the enclosure connector through the punched hole in Panel B. Reattach plastic nut from Step 11 and hand tighten until snug. Note that the step secures the enclosure connector to Panel B only and that power cord can still move. CLIMATERIGHT-CR12000SACH-
Mini Split-Air-Conditioner-And-Heater-016

Secure the wire to the enclosure connector by tightening the pressure nut on the left as indicated. Set aside until later steps.

From the Panel A & B opening on the outdoor unit, carefully pull out the loose indoor unit wiring harness as shown. Either slide the zip tie or cut it to allow enough length so that the wiring harness can be threaded through the machine to the Panel C opening.

CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-017

The wiring harness should be pulled out of the Panel C opening so that it can be connected to the matching wiring harness that is bundled with the interior unit line set.

Remove the left screw on the strain relief as shown and set aside. Take care to avoid dropping screw into the unit. Then pivot the top half of the strain relief out of the way as shown. CLIMATERIGHT-CR12000SACH-Mini Split-Air-
Conditioner-And-Heater-018

Unscrew brass grounding screw as shown and remove screw and both washers from unit. Again, take care as screw and washers can roll or fall into unit once they are loose.

Once the grounding screw is removed, slide it into the green grounding wire terminal on the power cord. Ensure that both washers are between the screw head and wire terminal as shown.

Carefully holding the brass grounding screw, washers, and terminal together, begin to tighten screw onto the unit as shown. Once the screw has been sufficiently threaded into the hole so as not to come off unexpectedly, bend the green grounding wire as shown and then finishing tightening the brass grounding screw.

Loosen the screws in the two unused terminals in the terminal block on the lower left labeled L and N. Slide the spade connectors on the ends the black and white wires from the power cord into the terminal block of the unit and tighten screws. The black wire must be connected to the L terminal and the white wire to the N terminal.

Route all 3 wires (White, Black, and Green) through the strain relief and tighten with screw removed in Step 16.
Place Panel B back on unit and tighten with 3 screws and plastic washers. Then return panels A and C as well, securing with screws and plastic washers.

CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-021

INSTALLATION OF INDOOR UNIT

Pipelines can be routed in the order of: 1, 2, 3, 4, and 5 as indicated. (Fig. A)
A groove has to be opened on the base stand if pipes 3, 4, or 5 have been connected. (Fig. A)

  1. Installation of Wall-mounting
    Plate Attach the wall-mounting plate firmly to the wall with screws. Make sure to level the plate. A slanted wall-mounting plate might jeopardize the discharge of the condensed water.

  2. Drill Holes on the Wall
    Drill holes slightly below the wall-mounting plate, with hole diameter of 65mm (2 9/16”) and the outer hole 5-10mm (3/16-3/8”) lower as shown (Fig. B). This allows the condensed water to flow out properly. Cut the wall penetrating pipe to proper length according to thickness of the wall

  3. 5mm (1/8-3/16”) lo nger than the wall thickness and insert the pipe as indicated.

  4. Installation of Drain Pipe
    Install the pipelines of the indoor unit in accordance with the direction of the wall holes. Tightly wrap the drain pipe and the pipelines with tape. Make sure that the drain pipe is underneath the pipelines.
    (Fig. C) Condensation may occur on the surfaces if the humidity is very high .CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-023

  5. Installation of Indoor Unit
    Attach the connection wires, connecting pipelines and drain pipe through the wall Hang the indoor unit on the hooks at the top of the wall-mounting plate so that the hooks at the bottom of the indoor unit match the hooks of the wall-mounting plate. (Fig. D)

Inspections

  • * Check if the hooks at the top and bottom are firmly fixed.
    • Check if the position of the master unit is properly leveled.

    • The drain pipe should not curve upward (Fig. E).
      CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-024

    • The drain pipe should be at the lower part of the wall pipes (Fig. E).

SET-UP INSTRUCTIONS

  • As the gravity center of the unit is not at the installation center, special caution should be taken when using hoisting cables to lift it up.
  • During shipping, do not slant the unit to over 45 degrees. (Unit should also be stored in upright position.)

resist earthquakes or strong winds. Dimensions for parallel units installations

CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-025

WHOLE-UNIT
Whole-Unit type quick coupler pipeline connections

STEP 1
Remove three screws on the maintenance plate with a screwdriver and take off the plate, remove the dust caps on both indoor male coupler and outdoor female coupler.
CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-026

STEP 2
Press the projecting section of outdoor female coupler backward with a little force by the thumb to make inner hooks open, and then you can easily take out the outdoor valve for gas leaking by the other hand.

STEP 3
In the same way, press the projecting section backward, connect the indoor male coupler to the outdoor female coupler.
CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-027

Next step continued on next page

WHOLE-UNIT

STEP 4
Close the key lever of indoor male coupler to the horizontal position. You can now hear the indoor and outdoor refrigerant will be clrculatlng.

STEP 5
Connect the outdoor quick cable coupler with the indoor quick cable coupler.

STEP 6
Keep the outdoor valve for and the dust caps for future possible use on the removal of your air conditioner.
Note : Ensure the electrical quick couplers are properly connected. The appliance should be installed in accordance with national wiring regulation. lf the supply cord is damaged, it must be replaced by the manufacturer, or qualified service agent.
Finishing touches.

  • Wrap the pipelines tightly with ethylene tape.
  • Fix the wrapped pipelines on the exterior wall with clamps.
  • Fill in the gaps left over by the pipeline hole and wall hole to prevent rain-water from entering.

Test

  • Connect outdoor unit to power source then:
  • Check if the function selection keys on the remote controller are working properly.
  • Check if the room temperature adjustments and timer settings are working properly.
  • Check if the drain is working properly.
  • Check if there are any abnormal noises or vibrations during operation.
  • Check if there is any leakage of refrigerant.

MAINTENANCE AND CARE

Power Cord Care

  • Do not rest anything on the power cord
  • Do not place the Mini-Split Air Conditioner condenser where people or pets may trip over or walk on the power cord
  • Do not pick the unit up by the power cord
  • Inspect the power cord before use to ensure the cord and plug are in good condition

Inspection and maintenance

  • According to the service conditions and operating environment, the inside of the air conditioner will become dirty after several seasons (3 to 5 years) of service, resulting in decreased operating performance. Inspection and maintenance are recommended annually in addition to usual cleaning
  • We recommend performing inspection and maintenance during off-season Before carrying out any maintenance, disconnect the power supply by unplugging the outdoor unit from the wall outlet.

Indoor Unit
Antidust Filters

  1. Open the front panel.
  2. Keeping the front panel raised with one hand, take out the air filters with the other hand.
  3. Clean the filters with water; if the filter is soiled with oil, it can be washed with warm water not to exceed 45 degrees C. Leave to dry in a cool and dry place.
  4. Keeping the front panel raised with one hand, insert the air filters with the other hand.

The Heat Exchanger

  1. Open the front panel of the unit and lift it till its greatest stroke and then unhooking it from the hinges to make the cleaning easier.
  2. Clean the indoor unit using a cloth with water and a neutral soap. Never use aggressive solvents or detergents.
  3. Wipe any remnants of soap from the heat exchanger. Allow to dry before replacing the front panel.

Outdoor Unit
Seasonally give the outdoor unit a light misting of water to remove any debris that may have accumulated throughout the season. PLEASE NOTE: DISCONNECT FROM WALL OUTLET BEFORE PERFORMING THIS STEP AS TO AVOID ANY ELECTRIC SHOCK.

TROUBLESHOOTING

CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-And-
Heater-030

This unit is programmed with error codes that allow us to pinpoint the root cause of any issues. Below is a list of each error codes and what aspect of the unit is affected. CLIMATERIGHT-CR12000SACH-Mini Split-Air-Conditioner-
And-Heater-031

LIMITED WARRANTY

ClimateR ight products (“Climate Right”) are warranted by Climate Right LLC, the manufacturer, and the distributor of Climate Right portable air conditioning and heating products and air purification products to be free from defective workmanship and materials. Climate Right portable air conditioners, heaters, and air purifiers are warrantied to the original owner only, for one (1) year from the date of purchase against manufacturer defects under normal use and service. This Warranty is not transferable and applies only to original purchases and original purchase dates. After the expiration of the Warranty term (1 year), the owner is responsible for all costs associated with repair or troubleshooting.

ITEMS NOT COVERED IN THE WARRANTY

  • Cosmetic damage such as scratches and dents
  • Normal wear and tear on parts or replacement parts designed to be replaced, such as filters and hoses
  • Optional accessories, attachments, and appearance items
  • Products lost in shipment or theft
  • Products sold AS IS or from an unauthorized reseller

WHAT WILL CAUSE A VOID OF WARRANTY?
Although Climate Right products are versatile and can be used in many non- permanent applications, they cannot be expected to operate and maintain its intended quality when used in extreme or unreasonable circumstances and applications. If any of the following apply the warranty will be voided regardless of the purchase date

  • Climate Right products that have been altered or customized
  • Climate Right products that have damage or failure due to improper maintenance. Please refer to the maintenance instructions provided in the owner’s manual
  • The use of ClimateRight products in commercial settings or in settings not specifically recommended on our official company website
  • Products that have been modified to perform outside of specifications without the prior written permission of Climate Right, LLC
  • Products that have had their serial numbers removed, defaced, or been invalidated Permanent mounting of these products to moving vehicles

HOW TO FILE A WARRANTY CLAIM
All warranty claims must be submitted in writing or received and confirmed by email from an authorized Climate Right representative. A web form is also available at www.climaterightair.com to submit your claim as well. If Climate Right LLC, at its sole discretion, deems your Warranty claim valid, a prepaid shipping label will be sent to the address provided for return of the climate right unit for inspection and repair or replacement. In good faith, we will send you out a replacement unit before receiving the defective unit back. If, during inspection, the unit has been found to be defect free or has been modified in any way to cause a defect, the customer will be charged for the replacement unit plus shipping and handling fees and no refund will be issued for the initial purchase. If the unit has been found to be defective the original purchase price will be refunded.

Please note: Any damage caused by improper packaging of the return unit to the authorized service center will void the warranty.

BUYER’S REMORSE POLICY
If you are not completely satisfied with the product received, Climate Right will accept the return of the product within 30 days from the date of purchase. Customer will be responsible for the return shipping costs associated with shipping the product back to Climate Right. Customer is responsible for the proper packaging of the product for return ensuring no damage to the product while in transit as well as any lost packages. Once we receive the product back, we will do a thorough inspection verifying that there is no damage to the product and that all accessories are included, and will, at that time, issue a full refund.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals