BEOK TGM50 Thermostat User Guide
- June 13, 2024
- BEOK
Table of Contents
TGM50 THERMOSTAT USER GUIDE
Welcome
Thank you for your trust and support!
We have adopted advanced technology and perfect craftsmanship so that your new
thermostat will provide you with a suitable temperature environment every day
in the future. It makes your life more pleasant and artistic and making your
living environment more fashionable aesthetic.
For detailed instructions on installing and using this thermostat, please read
this manual carefully.
Please get in touch with a professional to install the thermostat for you.
Besides, please install and use this product within the scope of the law.
Application
The intelligent digital humidity controller is a floor heating system suitable
for room temperature control and household temperature control. It controls
the operating status of the floor heating equipment by sensing the comparison
between the ambient temperature and the set temperature. While improving
comfort, it achieves the purpose of energy saving.
The digital thermostat adopts microcomputer control technology and has an
elegant design, and is easy to use. Moreover, it has manual and automatic
functions, programmable functions, and state memory functions.
Product Package
Thermostat host | 1 pc |
---|---|
Guide/manual | 1 pc |
Certificate of conformity | 1 pc |
Screw | 2 pcs |
External sensor (optional) | 1 pc |
Electrical Specifications
- Temperature Sensor : NTC
- Temperature accuracy : 土1°C
- Display screen: LCD
- Working environment: -5~50°C
- Self-consumption power: <1W
- Temperature setting : 5~60° C
- Display range: 0~51°C .
- Load current: water heater 3A electric heater 16A gas boiler 3A
- Voltage : AC100- 240V, 50/ 60Hz
User Instructions
- Read this manual carefully. A general operation may damage the product or cause a dangerous situation.
- The installation personnel must be well -trained and experienced service technicians.
- After the installation is complete, please close this manual carefully and operate this product following the user guide.
Note: There is a risk of electric shock or equipment damage.
Wiring Diagram
Note: WP for water heating; EP for electric heating; WPB for gas boiler
Mounting Steps
- Connect the power box according to the wiring diagram
- Separate the power supply from the control board cable
- Screw the power supply into the boxof 86
- Connect the power board to the control board line, and align the buckle at 30 degrees to complete the installation.
Icon Description
Operation Guide
- Power on/off: press the key to turn on/of the thermostat.
- Press the M key to switch between Manual and Leave modes.
- Simultaneously press and hold the and keys for 5 seconds to add or cancel the child lock.
- WIFI link: When the thermostat is turned on, press and hold the button for five seconds, the Wi-Fi icon flashes on the thermostat display, and the thermostat enters the Wi-Fi configuration state.
Time Programming Instructions
Options| Icon| Time| Time Adjustment| Defaults|
Temperature adjustment
---|---|---|---|---|---
Working days| 1| | 6:00| | 20t|
2| | 8:00| 16t
3| | 11:30| 16t
4| | 12:30| 16t
5| | 17:00| 22t
6| | 22:00| 16t
Holidays| 1| | 8:00| 22t
2| | 23:00| 16t
Advanced Option Setting
In the POWER OFF state, long press the M key and key for 5 seconds to enter
the advanced option setting.
Press the M key to enter the next option, then press the key or keyto adjust
options. Press key to exit the advanced option setting mode.
1| Temperature compensation| The default value of the calibration room
temperature is -2 °C. Press the up or down key to adjust the range from 9.9 °C
to -9.9 °C.
---|---|---
2| Sensor selection| The temperature sensor selection defaults to IN. Press
the up key or down key to adjust it respectively as IN internal sensor
selection. ALL means all internal sensors are selected; OUT means external
sensors are set.
3| Limit temperature value modification| The limit temperature value is 60°C
by default. Press the up or down key to adjust the range from 35°C to 60°C .
4| Temperature accuracy| The default setting temperature accuracy is 1°C;
press the up or down key to adjust the range from 0.5°C to 10°C.
5| Antifreeze function| The default setting for antifreeze function is OFF;
press the up key to turn on the function. ATT: if Antifreeze function is
turned on, when you turn off the thermostat, the room temperature and power
key is still displayed.
6| Rest day selectior (optional) and closing weekly program| 5: Two-day
weekend 6: Single day off
7: No rest OFF: Turn off programming
7| Main and auxiliary reverse selection (optional)| Set the main and auxiliary
reverse to 00 by default. Press the up or down key to adjust 00 main reverse ,
and 01 indicates the auxiliary reverse.
ATT: it is not recommended to adjust without professional guidance.
8| Standby backlight brightness| 00: Turn off the backlight
1:Brightness always on (Low)
2:Brightness always on (Mid)
3:Brightness always on (High) The default setting is 03
9| Set temperature limit| Set the upper limit of the temperature to 60°C;
press the up or down key to adjust the range from 15°C to 95°C.
10| Sound| ON: Turn on the sound OFF: Turn off the sound
11| Window opening detection| ON: Turn on the window opening detection OFF:
Turn off the window opening detection The default setting is ON.
ATT:
When the window opening detection is turned on, if the room temperature drops
by 6 °C within 4 minutes, then window opening mode will be triggered. At this
time, the
thermostat will stop heating, and the window opening detection icon is
displayed.
After the window opening mode is triggered, in the following three conditions,
the mode will be exited:
1.the room temperature rises by 3 °C
2.48 minutes after triggering
3.manual
12| Power outage memory function| 0: memory function
1: Turn on after turning on the power
2:Turn off after turning on the power
13| Reset| Set to restore factory settings The default display is “-” press
the up key to display “–_”, and then press the enter key to restore the
factory settings.
About Wi-Fi Connection
Before using the WIFI temperature controller for the first time, you must set
the WIFI value number and configuration via your smart phone or tablet, which
will allow communication between your connected devices.
WIFI connection: When the thermostat is turned on, press and hold the up
button for 5 seconds, the WIFI icon flashes on the thermostat display, and the
thermostat enters the code matching state.
WIFI conection: Bluetooth thermostat, please turn on the phone’s Bluetooth
-
APP download
Search for “Tuya Smart” in each APP market or scan the following QR code to download this software:http://smart.tuya.com/download -
Register an account
If you do not have an APP account, you can choose to register or log in via SMS verification code. Click “Create New Account” to enter the privacy policy page of Tuya Smart Platform. After clicking Agree, you will formally join the registration page of your mobile phone number. The system automatically determines the current country/ region, or you can manually select the country/region, enter your phone number or email address, and click “Get the Verification Code”.
Enter the received verification code. Then enter the password. Click “Finish” to register successfully. -
Add device
3.1: (Bluetooth connection) Turn on the mobile phone’s Bluetooth, turn the device on, and enter the Tuya APP. Click “Add Device” or “+” on the top right of the APP homepage, and enter the “Add Device” interface. It will prompt: find the device to be added (Figure 2) and follow the prompts.
3.2: “Automatic discovery”: Search for devices (Figure 3), and add widgets as prompted on the phone page3.3: (WIFI connection) When the thermostat is turned on, press and hold the up button for 5 seconds, the thermostat display will show.
Now the WIFI icon flashes (slow flashing), and the thermostat enters the status of code matching.
Find the temperature control product (Bluetooth + WIFI model) in the (small household appliances). In the specific network configuration mode, click the confirmation button on the page, select the WIFI that can connect to the Internet in the working area of the device, and enter it.
WIFI password, click Next, click according to the page prompt (Figure 2), Go to connect”, and follow the instructions to find the prompt content (Figure 3), click “Prompt content” and then return to the Tuya APP to enter the network configuration process.In that case, the APP for the network configuration process is shown in Figure 1,and the network configuration successfully displays the interface shown in Figure 2. The device’s name with successful ne twork configuration can bemodified, and the room’s location can also be selected.If the network configuration fails, the APP will display the page as shown in the figure below, and you can choose to add it again or view the help.
Note: Please confirm whether the thermostat enters the code matching state if the connection fails. -
Thermostat APP interface display
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>