1. MOUNT THE SENSOR

Using the mounting template supplied mount the sensor within 50mm of the bottom of the door controller cover.

  1. Max 50mm
  2. 3.0m (9.84ft) or less
2. SET MAIN DIPSWITCHES AS ILLUSTRATED

Dip Switch (X)

  1. Presence Timer: 30s
  2. No. Rows of Detection: 5 rows

Dip Switch (Y)

  1. Frequency: A (Change if another HR100 sensor is close by)
  2. Safety Output: N.C.
  3. Reflection Diagnostics: OFF

Dip Switch (Z)

  1. Direction Detection: OFF
  2. Activation Output: N.O.
  3. Monitor (Snow) Mode: OFF
  4. Door Hold Open: OFF
  5. Door Learn: OFF
  6. Test Input: ON (Set to OFF for nonEN16005 doors)
3. CONNECT TO THE DOOR CONTROLLER

Note: For EN16005 door controllers set Z6 to “ON” and connect the Gray & Brown wires to the door controller. If the door controller does not have a “TEST INPUT” set Z6 to “OFF” and do not connect the Gray & Brown wires

HOTRON HR100-CT Automatic Sliding Door Activation A3

A: Sensor’s Cable
B: Cable
C: OFF
D: ON

  1. Red
  2. Black
  3. White
  4. Green
  5. Yellow(+)
  6. Blue(-)
  7. Gray(+)
  8. Brown(-)
  9. N.O.
  10. COM
  11. Collector
  12. Emitter
  13. Test-P
  14. Test-N
  15. Power (Non Pole)
  16. Activation Output Rows 2,3,4,5
  17. Safety Output Rows 1,2
  18. Test Input Door Controller
4. LED INDICATORS
Green Standby.
Flashing Green  Doorway Learning (When dip switch (Z) 5 is ON).
Flashing Green (once) When responding to the TEST signal
Blue ROW 4,5 Detecting.
Red ROW 3 Detecting
Slow flashing Red ROW 2 Detecting
Fast flashing Red ROW 1 Detecting
Orange Detection row “ROW1”(“ROW2” when doorway Learning is turned ON) is

detecting door movement.
Fast flashing Orange| Indicates a change of dip switch settings.
Slow flashing Orange| Door Hold is turned Open (When dip switch (Z) 4 is Open)
Fast flashing Green/Red | Internal Sensor Error.
Slow flashing Green/Red| Reflected infrared signal from the floor is very low.

5. SET SAFETY DETECTION AREA

  With Base

  1. Depth adjustment lever: Inner 3 rows

  2. [0 degree] setting

  3. [-8 degree] setting

Note: Adjust the depth adjustment lever arm so that the detection area is directly in front of the moving door leaf. The sensor base can be removed if required.

6. SET DESIRED DOOR OPENING DETECTION AREA

With Base

  1. Depth adjustment lever: Outer 2 rows

  2. [+10 degree] setting

  3. [0 degree] setting

  4. Width Adjustment: Inner 3 rows

  5. Adjustment: Outer 2 rows

7. DOOR LEARN

Turning Door Learn ON (Z5) , allows the 1st row of detection to be focused inside the door close area without detecting door movement.
When Door Learn is turned on, the red LED will blink once, followed by a green blinking LED, which will turn solid green once the door learn process has been completed.

  1. [0 degree] setting
  2. [-8 degree] setting
  3. 1st row of detection in front of the moving door
  4. 1st row of detection inside of the moving door

Note: Sensor base plate will probably have to be removed to allow the 1st row of detection to be focused inside the moving door leaf

8. OTHER USEFUL DIPSWITCH SETTINGS

Delete rows of detection (Dip Switch (X) )| 5 Rows ON| 4 Rows ON| 3 Rows ON| 2 Rows ON
---|---|---|---|---
| | |
Snow Mode (Dip Switch (Z) )| Normal| Snow
Adjust sensor frequency settings to prevent cross interference between sensors in close proximity (Dip Switch (Y) )| A| B| C| D
Turn ON/OFF Unidirectional detection (Dip Switch (Z) )| OFF| ON

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals