HOTRON SSS-5S1 Safety Sensor for Automatic Swing Doors User Manual

October 30, 2023
Hotron

HOTRON SSS-5S1 Safety Sensor for Automatic Swing Doors

Product Information: Safety Sensor for Swing Doors (MP-10345-B ‘21.12)

The SSS-5 is a microprocessor-controlled active infrared presence detector for swing doors. It is compliant with standards DIN18650-1:2010, EN 12978:2003 +A1:2009, and EN16005:2012. The product has an EC type examination 44 205 13738001. The SSS-5 has six detection spots per PCB unit, providing a wide detection area.
The detection distance to the floor is set automatically by pressing a push switch. The detection range can be adjusted manually, using dip switches in increments of 50mm. The relay output can be changed from NO to NC using a dip switch. Self-diagnostic and monitoring functions are implemented.

Features:

  • Microprocessor-controlled active infrared presence detector
  • Six detection spots per PCB unit
  • Automatic detection distance to the floor by pressing a push switch
  • Manual detection range adjustment using dip switches
  • Relay output can be changed from NO to NC using a dip switch
  • Self-diagnostic and monitoring functions

Usage Instructions

Before using the SSS-5, please read the following instructions carefully:

  1. Ensure the SSS-5 is not mounted higher than 2.6m (8′ 6″) and not in direct contact with rain or snow.
  2. Ensure minimum reflection of sunlight from the floor and that no condensation gets onto the sensor.
  3. Locate the Aluminum Case(s) close to the leading edge of the door to maximize safety detection.
  4. Be careful not to drop the sensor during transportation and installation as it may cause the sensor to break.
  5. Drill fixing holes as illustrated in the manual. When installing the SSS-5 on both sides of the door, it may be necessary to drill a wiring hole through the door.
  6. Install the Jamb Hole Cover and Wire Sheath when wiring to the door controller. Clamp the Wire Sheath between the Jamb Hole Cover A/B. Connect the wires to the door controller using the Terminal Block.
  7. Adjust the detection range manually using dip switches in increments of 50mm.
  8. Change the relay output from NO to NC using a dip switch.

WARNING: Disregarding this symbol may result in serious injury or death

CAUTION:   Disregarding this symbol may result in injury or damage to equipment

Note: Special attention is required when this symbol is shown

EN16005:   Setting required to conform with EN16005

General Description / Features

The SSS-5 is a microprocessor controlled active infrared presence detector for swing doors.

  • 6 detection spots per PCB unit provide a wide detection area.
  • The detection distance to the floor is set automatically by pressing a Push Switch.
  • The detection range can be adjusted manually, using dip switches in increments of 50mm
  • The relay output can be changed from NO to NC using a dip switch.
  • Self diagnostic and monitoring functions are implemented.

Components

The illustration below shows the standard configuration of SSS-5L1 with one PCB units.

Table.1 Information of SSS-5

Model

name

| Length [mm]| Filter

Cover

| Joint| (3)
---|---|---|---|---
SSS-5S1| 360| 1| 0| 2
SSS-5M1| 692| 2| 1| 3
SSS-5L1| 1023| 3| 2| 3

Accessories

Mounting and Wiring Information

Notice

CAUTION Before mounting this sensor please note the following remarks.

  1. Do not mount the sensor higher than 2.6 [m]( 8′ 6″ ).
  2. Do not mount the sensor where rain or snow will fall directly on the unit.
  3. Ensure the minimum of reflected sunlight from the floor.
  4. Ensure no condensation gets onto the sensor.
  5. The Aluminum Case(s) should be located close to the Leading edge of the door to maximize safety detection
  6. Be careful not to drop the sensor, during transportation and installation. It may cause the sensor to break.

Mounting Hole
Drill fixing holes as illustrated below.
When installing the SSS-5 on both sides of the door it may be necessary to drill a wiring hole through the door. (Ref. 3.6 Plan View of SSS-5 Installation)

WARNING: Drilling may cause Electric shock!     When drilling, pay attention to hidden wires.

Mounting the Aluminum Case

  1. Unscrew the Side Covers and remove the Filter Cover. ****

  2. Remove Angle Stabilizer.

  3. Lift and slide the Angle Stabilizer to the side as indicated.

  4. Push the Angle Stabilizer with your thumb to remove it

  5. Remove the PCB Unit.
    Loosen the Screw on the PCB Holder and slide it aside to remove the PCB Unit.

  6. Fix the Aluminum Case to the door with Screws

Replacing the PCB unit(s)

  • CAUTION: When replacing the PCB unit it is very important that the side with “LEADING EDGE” marked on it is inserted so that it is closest to the leading edge of the door. This will ensure maximum pedestrian safety at the door edge.
  1. Remove the Terminal Block from the PCB unit
  2. Insert the PCB unit into the Aluminum Case, making sure that the side  marked “LEADING EDGE” is closest to the leading edge of the door.
    Attach the Angle Stabilizer and tighten the screws on the PCB Holders.

Wiring to the door controller
Install the Jamb Hole Cover and Wire Sheath when wiring to the door controller.

1 Power supply ( AC/DC 12~24[V] )

2
3| Relay Output ( Common )
4| Relay Output1
5| Relay Output 2(Another PCB Unit Output)
6| TEST Input ( – )
7| TEST Input ( + )

Option 1: Plan View of SSS-5 Installation

(PCB units on both sides of the door wired back to the Door Controller independently)

Option 2: Plan View of SSS-5 Installation

(PCB units connected using Communication Cable and only 1 PCB units is wired back to the

Dip Switch Settings

In order to prevent dangerous door movement ! please configure sensor Dip-SW setting.

WARNING: Before supplying power to the sensor.

**TEST Input

EN16005:** Set to “B” to comply with EN16005

When connected to a door controller without a TEST input, set to “A”. When connected to a door controller with a TEST input, set to “B” before wiring.
Refer to [6.Timing Chart of events] .

Optical Interference

When two SSS-5’s are installed in close proximity , optical cross interference between SSS-5’s might cause mis-operation. To avoid this , different frequency settings should be selected using DIP Switch #2.

Relay Output Mode

Refer to [6. Timing chart of events] for full details on Relay Output Mode.

Masking detecting spots

Detection Range

Set Non-Detection distance A

EN16005: Check that the detection range conforms to EN16005

Detection Angle Adjustment

The detection angle can be adjusted between 5 ~ 25 [deg] in 5 [deg] increments using the Angle Stabilizer. Example) Changing angle from 5゜to 25゜

EN16005 Check that the detection area position conforms to EN16005

Timing chart of events

LED information

Normal state

Error state

N Error category Cause Solution
1 Environmental error Environmental noise or the reflection level from the
floor is too low. Execute the “TEACH” from Section 8 whilst laying a sheet of

white paper on the floor.
3 over| Other Error| Internal component failure| Change the units.

Teaching

Conduct the following steps with the Filter Cover off.

Check the wiring connection and supply power. 2 Execute “TEACHING”
“TEACHING” is necessary to make the sensor work properly, that is to learn the distance from the sensor to the floor.

STEP 1.
Press the “Push SW” switch for more than 2 seconds.

STEP 2.
LED blinks slowly for 10 sec’s in a non-detection state. Ensure that there are no people or objects (ladder etc) in the detection area during this time.

STEP 3.
After STEP2, LED blinks faster and starts ” TEACHING”. If during this time, a person or object is in the detection area, try again from STEP 1.

STEP 4.
After STEP3, the green LED blinks once and then this process is completed.

Check the adjustments , range and other setting.

Detection Area

FRONT VIEW                                                       SIDE VIEW

Detection Range Check without Filter Cover
Check the detection range without the Filter Cover attached.
Put a test object in the detection area to check the detection patterns and other Dip Switch settings. Tests according to local standards should be carried out.

After this check, Turn power off.

EN16005 Check that the detection area conforms to EN16005
When the test is completed, go to Section 11 to install the Filter Cover and Side Cover. If an error occurs, re-check the settings referring to Section 3.

Replacing the Filter Cover and Side Cover

Installing the Filter Cover:

Attaching the Joint

  1. Snap the Joint into the Aluminum Case.
  2. Slide the Joint so that it fits snugly into the Filter Cover. Make sure there are no gaps left.
  3. Attach remaining Filter Covers as illustrated

Cut out the Side Cover wiring point and insert the Wire Sheath into it.

Attach the Side Cover with Screws provided.

Final Detection Range Check
After the Filter Cover is fitted, confirm that the detection range is as expected and conforms with local regulations.

EN16005: Check that the detection area conforms to EN16005

Technical Data

MODEL| Safety Sensor for Swing Doors      SSS-5|
---|---|---
TECHNOLOGY| COMPLETE STATIONARY DETECTION with PSD DISTANCE MEASUREMENT|
POWER SUPPLY| AC/DC 12~24[V] ±10%| BEAM ANGLE ADJUSTMENT| 5 , 10 , 15 , 20 , 25 [degrees]|


CURRENT CONSUMPTION

| 95 [mA] @ DC12[V]

55 [mA] @ DC24[V]

1.7 [VA] @ AC12 [V]

2.3 [VA] @ AC24[V]

| RESPONSE SPEED| LESS THAN 100 [mSec]|



DIP SW FUNCTIONS

| ****

TEST INPUT : 1 [BIT] OPTICAL INTERFERENCE : 1 [BIT]

RELAY OUTPUT MODE :1 [BIT] MASKING DETECTING SPOTS:2[BIT] DETECTION RANGE:3[BIT]

|


RELAY OUTPUT

| OPTO RELAY 1A (NON POLE)

DC 50[V] 0.1[A] (RESISTANCE LOAD)

|
OPERATING TEMPERATURE| -20 ~ +60 [゜C]|
TEST INPUT| 6 [mA] Max. at 24 [VDC]|
MOUNTING HEIGHT| 2.6 [m] Max| ****

WEIGHT

| SSS-5S1: 350[g] APPROX. SSS-5M1: 540[g] APPROX. SSS-5L1: 760[g] APPROX.|
DETECTION RANGE| 0 – 2.55 [m] Max|

Dimensions

EC DECLARATION OF CONFORMITY

Description of Product:
SSS-5 Safety Sensor for Swing Doors .
Complete stationary detection with PSD distance measurement.

Directives Fulfilled:

  • DIRECTIVE 2006/42/EC Machinery Directive
  • DIN 18650-1:2010 Powered pedestrian doors Part 1: Product requirements. Chapter 5.7.4
  • EN12978:2003 +A1:2009 Industrial, commercial and garage doors and gates – safety devices for power operated doors and gates – Requirements and test methods.
  • EN62061:2005 Functional safety of electrical/electronic/programmable electronic safety-related systems.
  • EN ISO 13849-1:2008 /AC:2009 Safety of machinery – Safety-related parts of control systems.
  • EN 16005:2012 Power operated pedestrian doorsets – Safety in use – Requirements and test methods. Chapter 4.6.8
  • EC type examination No. 44 205 13738001

Above EC Type Directives Certified by: TUV NORD CERT GmbH Langemarckstr.20 45141 Essen Germany Identification No: 0044

Harmonized Standards Used:
EN ISO 13849-1:2008/AC:2009

Other Technical Standards Used:
DIN 18650-1:2005 EN16005:2012

Compiler of Technical File (EC Community)
David Morgan / Hotron Ireland Ltd.
26 Dublin Street, Carlow, Ireland
Ph: +353 5991 40345 Fax: +353 5991 40543

Location of Declaration (Manufacture)
Honda Electron Co., Ltd.
1-23-19 Asahi-Cho,Machida-City, Tokyo, Japan

Declaration made by
Teruya Morimoto Director
Quality Assurance

Date
30
September
2015

Disclaimer> The manufacturer cannot be held responsible for the below.

  1. Misinterpretation of the installation instructions, miss connection, negligence, sensor modification and inappropriate installation.
  2. Damage caused by inappropriate transportation.
  3. Accidents or damages caused by fire, pollution, abnormal voltage, earthquake, thunderstorm, wind, floods and other acts of providence.
  4. Losses of business profits, business interruptions, business information losses and other financial losses caused by using the sensor or malfunction of the sensor.
  5. Amount of compensation beyond selling price in all cases.

Manufacture and Sales
HOTRON CO.,LTD.
1-11-26 Hyakunin-Cho, Shinjuku-Ku, Tokyo, Japan
Phone: +81-(0)3-5330-9221
Fax: +81-(0)3-5330-9222
URL: http://www.hotron.com

Sales in Europe
Hotron Ireland Ltd.
26 Dublin Street (2nd Floor), Carlow, Ireland |
Phone: +353-(0)59-9140345
Fax: +353-(0)59-9140543
URL: http://www.hotron.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals