HINKLEY 45016TXP Pendant Light Fixture Instruction Manual

June 13, 2024
HINKLEY

HINKLEY 45016TXP Pendant Light Fixture Instruction Manual
HINKLEY 45016TXP Pendant Light Fixture

Assembly Instructions

  1. Find a clear area in which you can wor
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly.

DRAWING 1 – ASSEMBLY

ASSEMBLY

  1. To begin assembly of your fixture, unfold the fixture arms as shown in drawing 1.
  2. slide nipple (2) onto fixture wires and secure it to bottom wire body (3) using hex nut – see DRAWING 1.
  3. Place stem (1) over the nipple (2).
  4. Slide loop (4) along wires and thread it onto the top of the nipple (2). Make sure all connections are tight

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRI-CIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS

To install your fixture to the ceiling follow instruction sheet IS-19 provided. Please read through all instruction sheets supplied with your fixture prior to installation

Hanging Instruction

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

  1. Shut o electrical current before starting. If the fixture you are replacing is turned on and o a wall switch, simply turn the switch o If not, remove the appropriate fuse (or open the circuit breakers) until the fixture is dead.
    • DO NOT restore current – either by fuse, breaker or switch – until the new fixture is completely wired and in place.

Drawing 1 – Hanging Instruction

Hanging Instruction 

  1. Fasten mounting strap provided – see (1) to outlet box ( A) with the two 8-32 screws ( 2) not Drawing 1 .

  2. Thread 2 – hex nuts ( 3a) and ( 3b) onto threaded tubing ( 4).

  3. Thread one end of threaded tubing ( 4) into loop ( 5) a minimum of 1/2’’ to 3/4’’.
    Tighten hex nut ( 3a) against loop ( 5) to lock loop in position.

  4. Thread other end of threaded tube ( 4) into mounting strap approximately 1/2’’.

  5. Slip canopy ( B) over loop ( 5) and adjust height of loop so half of the threaded area on the loop is exposed – see Drawing 2 below. After loop height is adjusted, tighten hex nut (3b) up against mounting strap, tighten against mounting strap to lock loop and threaded tube in position.

  6. Remove mounting strap ( 1) from junction box ( A), and thread third hex nut ( 3c) onto end of threaded tube ( 4) above the mounting strap, tighten against mounting strap to lock assembly in position.

  7. Remount mounting strap to junction box

Drawing 2 – Canopy Adjustment

Canopy Adjustment 

  1. Unwrap fixture lead wire and ground wire and weave them up through the chain.
  2. Slip fixture lead wire and ground wire through center of loop ( 5).
  3. Connect ground wire to mounting strap ( 1) using green ground screw ( GS).
  4. Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet ( I.S. 1 8) and follow all instructions to make all necessary wiring connections.
  5. Slip canopy up firmly against the ceiling and secure by turning the threaded collar ( 6) on loop ( 5) until tight.
  6. Quick links (Q) provided can be used for the first and last chain link.

Wiring grounding instructions

SAFE TY WARNI NG: READ WIRIN G AND GR OUNDING INSTRUCTIO NS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSU LT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS

wiring instructions

Indoor Fixtures

  1. Connec t positi ve supp ly wir e (A ) (typical ly black or the smoo th, unma rked side of the two-conduc tor cord) to positi ve fi xture lead (B ) wit h ap propri ately sized t wist on connec tor – see Dra w ings 1 o r 2.
  2. Connec t nega ti ve supp ly wi re (C) (t ypica lly white or the ribbed , marked side of the two-conduc tor cord) to nega tive fi xture lead (D).
  3. Please refe r to the grounding instructions below to complet e all electrical connec tion

Outdoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 2 or 3.

  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).

  3. Cover open end of connectors with silicone sealant to form a watertight seal.
    If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backpla te) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.

  4. Please refer to the grounding instructions below to complete all electrical connections.

Grounding instructions

Flush Mount Fixtures
For positive ground ing in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture moun ting strap (M) with the ground screw (S) – see Draw in g 1.
Grounding instructions

Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.

Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Draw in g 2.
Grounding instructions

Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.
Grounding instructions

HINKLEY 33000 Pin Oak Parkway.
Avon Lake, OH 44012 800.446.5539/440.653.5500 hinkley.com

HINKLEY logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals