HINKLEY 5163 LED Light Instruction Manual

June 13, 2024
HINKLEY

HINKLEY 5163 LED Light

Product Information

Product Name: HINKLEY
Item Number: 57863
Manufacturer: HINKLEY
Model: T24 JA8-2016

Product Usage Instructions

  1. Find a clear area in which you can work.
  2. Unpack the fixture and glass from the carton.
  3. Carefully review the instructions prior to assembly.
  4. To begin installation, remove the mounting plate (A) from the fixture back plate (B). This is accomplished by removing the four screws (C) located on the top and bottom of the back plate (B). Set the screws aside in a safe place for use later on – see Drawing 1.
  5. Next, feed the supply wires from the junction box through the large hole (H) in the mounting plate (A).
  6. Attach the mounting plate (A) to the junction box using two 8-32 screws (F) (NOT PROVIDED). Place a level on the top edge of the mounting plate to ensure it is level before tightening the screws (F).
  7. Make all necessary wiring connections following instruction sheet (I.S. 18) provided. Refer to the instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections. Then refer back to this sheet to complete the installation of this fixture.
  8. After wiring is completed, slip the back plate (B) over the mounting plate (A) and align the screw holes (I) in the back plate with the threaded holes (T) in the mounting plate. Thread in the screws (C) removed earlier to secure the fixture to the wall.
  9. Slide the glass (4) over the diffuser.
  10. Place the large cap (3) over the glass and secure it with screws (2).
  11. Thread the smaller cap (1) onto the larger cap (3).
  12. The fixture can now be powered on.

SAFETY WARNING:
Read wiring and grounding instructions (I.S. 18) and any additional directions. Turn power supply off during installation. If new wiring is required, consult a qualified electrician or local authorities for code requirements.

I.S. 18 Wiring Grounding Instructions:
Safety Warning: Read wiring and grounding instructions (I.S. 18) and any additional directions. Turn power supply off during installation. If new wiring is required, consult a qualified electrician or local authorities for code requirements.

Wiring Instructions

Indoor Fixtures:

  1. Connect the positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to the positive fixture lead (B) with an appropriately sized twist-on connector – see Drawings 1 or 2.
  2. Connect the negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to the negative fixture lead (D).
  3. Please refer to the grounding instructions below to complete all electrical connections

Outdoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Cover open end of connectors with silicone sealant to form a watertight seal.
    • If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
  4. Please refer to the grounding instructions below to complete all electrical connections.

Assembly Instructions

  1. Find a clear area in which you can work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly.

The assembly of this fixture will start by attaching the mounting plate to the junction box, making all necessary electrical connections, mounting the fixture to the wall.

  1. To being installation first remove mounting plate (A) from the fixture back plate (B). This is accomplished by removing the four screws (C) located on the top and bottom of back plate (B). Set screws aside in a safe place for use later on
  2. Next feed supply wires from junction box through large hole (H) in mounting plate (A).
  3. Next attach mounting plate (A) to junction box, using two 8-32 screws (F) NOT PROVIDED. Place a level on the top edge of the mounting plate, to make sure mounting plate is level before tightening screws (F).
  4. Next make all necessary wiring connections following (IS-18) provided.

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIRE-MENTS.
Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections. Then refer back to this sheet to complete installation of this fixture.

  1. After wiring is completed slip back plate (B) over mounting plate (A) and align screw holes (I) in back plate with threaded holes (T) in mounting plate and thread in screws (C) removed earlier, to secure fixture to wall.
  2. Next slide glass (4) over diffuser
  3. Next place large cap (3) over glass and secure with screws (2)
  4. Thread smaller cap (1) onto larger cap (3)
  5. Fixture can now be powered on

grounding instructions

Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S)

Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.

Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors

Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal

HINKLEY 33000 Pin Oak Parkway, Avon Lake, OH 44012 800.446.5539 / 440.653.5500