Product Information

The Downdraft Vent is a ventilation system designed for use with Dacor cooktops and ranges. It is available in various models, including HRV46, MRV3015, MRV3615, MRV48, MRV3015-ER, MRV36-ER, and MRV48-ER. The vent is equipped with a top cap and comes with installation instructions for the optional Dacor cabinet blower CABP3.
For installation or warranty inquiries, customers can contact Dacor Customer Assurance. The vent’s model and serial numbers can be found on the data label located on the front of the unit. The label also provides information about power-supply requirements.

Product Usage Instructions

  1. Before starting the installation process, review the planning guidelines provided in the user manual.
  2. Ensure that you have the necessary tools and equipment for installation.
  3. Contact Dacor Customer Assurance if you require assistance during the installation or have any warranty-related questions.
  4. Make sure to use the Downdraft Vent with approved Dacor cooktops and ranges only. The model numbers HRV, and MRV are compatible.
  5. Do not store or use any combustible or flammable substances near the vent, such as gasoline, alcohol, or benzene.
  6. Refer to the electrical specifications section to ensure that the vent is plugged into a suitable 3-prong outlet that meets the specified requirements.
  7. Follow all general safety precautions mentioned in the user manual to reduce the risk of fire, electric shock, personal injury, or property damage.

For detailed instructions on installation, planning the duct work, and other specifications, please refer to the complete user  manual available at <https ://manual-hub.com/>.

Before You Begin

  • Installer: In the interest of safety and to minimize problems, read these installation instructions completely and care-fully before you begin the installation process. Leave these installation instructions with the customer.
  • Customer: Keep these installation instructions for future reference and the local electrical inspector’s use.

Customer Assurance Information

If You Need Help

For installation or warranty questions/issues, contact Dacor Customer Assurance. Have available the vent’s model and serial numbers, which are on the data label on the front of the unit. This label includes power-supply requirements.

Model Identification
Use HRV, and MRV downdraft vents with approved Dacor cooktops and ranges only.

Model Number Description
HRV46 46” wide downdraft vent; HRV-style top cap
MRV3015 30” wide downdraft vent; MRV-style top cap
MRV3015-ER 30” wide downdraft vent; MRV-style top cap
MRV3615 36” wide downdraft vent; MRV-style top cap
MRV36-ER 36” wide downdraft vent; MRV-style top cap
MRV48 48” wide downdraft vent; MRV-style top cap
MRV48-ER 48” wide downdraft vent; MRV-style top cap

All specifications subject to change without notice. Dacor assumes no liability for such changes.
© 2018 Dacor, all rights reserved.

Important Safety Instructions

Important Information About Safety Instructions

  • The Important Safety Instructions and warnings in this manual do not cover all possible issues. Use common sense and caution when installing, maintaining, or operat-ing the appliance.
  • Contact Dacor Customer Assurance about issues and conditions you cannot resolve. (See Customer Assurance Information.)

DANGER
Do not store/use combustible, flammable substances (e.g., gasoline, alcohol, benzene) in/on/near the vent.

WARNING
TO REDUCE RISK OF PROPERTY DAMAGE AND PERSONAL INJURY, OBSERVE THE FOLLOWING

  • Installation work and electrical wiring must be done by qualified person(s) per applicable codes, including fire-rated construction.
  • Sufficient air is needed for proper combustion and exhaust of gases via the flue of fuel-burning equipment to prevent backdraft. Follow manufacturer guidelines such as are published by the National
  • Fire Protection Association (NFPA); the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE); and local code authorities.
  • Know the location of wiring and piping before cutting or drilling into a wall or ceiling.
  • Fans must always vent to the outdoors.

Safety Symbols and Labels

DANGER
Immediate hazards that WILL result in severe personal injury or death.

WARNING
Hazards or unsafe practices that COULD result in severe personal injury or death.

CAUTION
Hazards or unsafe practices that COULD result in minor personal injury or property damage.

WARNING
The unit has a 3-prong grounding plug to protect against electric shock. It must plug into a dedicated, 3-prong, grounded outlet. The owner shall ensure that such an outlet is available for the appliance. Do not

  • remove the third (ground) prong from the power cord.
  • use an adapter plug.
  • use an extension cord.
  • use a damaged power cord.
  • Use a ground fault interrupter (GFI).

Important Safety Instructions

General Safety Precautions
To reduce risk of fire, electric shock, serious injury, or death when using the vent, follow basic safety precautions, including

WARNING

  • Do not install a damaged appliance. If you receive a dam-aged appliance, contact your dealer or builder.
  • Observe all governing ordinances during planning and instal-lation. Contact the local building department for details.
  • The electrical outlet for the downdraft vent should be installed by a licensed electrician.
  • Do not vent hazardous or explosive materials and vapors through the unit.
  • Use this downdraft vent only as outlined in the User Manual. The vent is not designed for commercial use.
  • The owner should install/repair/replace partts only as specified in the product literature. A qualified technician should perform all other service. Contact Dacor Customer Assurance for examination, repair, or adjustment.
  • Keep all packaging away from children.
  • For proper operation, install the unit with a cabinet, in-line, or remote blower. Use only a specified model.

WARNING

  • Ensure the vent is unplugged for installation/service.
  • The installer must show the customer the outlet so the owner can unplug the vent as needed.
  • Install the vent as instructed in this manual, the Dacor range/cooktop installation instructions, and the blower installation instructions.
  • Read the User Manual completely before operating the vent.
  • Do not tamper with the vent controls.
  • Do not let the filters or vent openings become blocked. Do not let foreign objects be sucked into vent holes.
  • Clean the filters and all grease-laden surfaces often to pre-vent grease fires and maintain performance. Clean the appli-ance only as specified in the User Manual.
  • Do not leave children/pets unattended near the operating range/cooktop.
  • Do not let children play with the downdraft vent.

Product Specifications

Electrical Specifications

  • The downdraft vent comes with a 28” (71.1 cm) power cord with a 3-prong plug. Plug it directly into a 3-prong outlet meeting the requirements below.
  • The correct voltage, frequency and amperage must be sup-plied as specified below. The circuit must be protected by a properly sized circuit breaker or time-delay fuse.

Electrical-Supply Requirements
A 3-prong outlet connected to a 120 Vac, 60 Hz, 15 Amp. grounded, dedicated, single-phase circuit is required.

  • The above specifications are for reference only. If they conflict with spec’s on the product data label, use the spec’s on the label.
  • The customer must supply 3 conductor wiring/conduit with minimum 8-Amp current-carrying capacity to sup-ply power to the blower from the downdraft vent. (See Installation Specifications for details.)
  • The owner shall ensure the electrical outlet is installed by a licensed electrician. The electrical installation must comply with local ordinances and the latest revision of the National Electric Code

ANSI/NFPA 70 (latest revi-sion), a copy of which may be obtained from

  • National Fire Protection Association 1 Batterymarch Park
  • Quincy, Massachusetts 02269-9101
  • The electrical outlet situated so the vent can be unplugged for service without removing appliances from the cabinet.

Product Dimensions: MRV3015, MRV3615

Tolerances: ±1/16” (±1.6 mm) unless otherwise stated

Model A – Top-Cap Width B – Chassis Width
MRV3015 30” (76.2 cm) 27 3/8” (69.5 cm)
MRV3615 36” (91.4 cm) 33 3/8” (84.8 cm)

IMPORTANT
INSTALLER: To ensure the cooking unit performs properly, seal all seams around the motor cover where it contacts the vent chassis with aluminum tape. (See the graphic below for motor cover location.)

See pages 9 and 10 for exhaust locations and dimensions.

  • Total chassis depth with optional CABP3 blower installed is 10 3/8” (26.3 cm).
  • Maximum height of downdraft vent must not exceed maximum specified counter height for cooking appliance. See installation instructions for cooking appliance.

Product Dimensions: HRV46, MRV48

Tolerances: ±1/16” (±1.6 mm) unless otherwise stated

Model No. A – Top-Cap Width B – Chassis Width
MRV48 48” (121.9 cm) 43 3/8” (110.2 cm)
HRV46 46” (116.8 cm) 43 3/8” (110.2 cm)

IMPORTANT
INSTALLER: To ensure the cooking unit performs properly, seal all seams around the motor cover where it contacts the vent chassis with aluminum tape. (See the graphic below for motor cover location.)

  • Product Dimensions : MRV3015-ER, MRV36-ER, MRV48-ER
  • Tolerances: ±1/16”, (±1.6 mm) unless otherwise stated

Model Number| Top Cap Width (A)| Chassis Width (B)| Height (C)| **Trim Part No.***
---|---|---|---|---
MRV3015-ER| 30” (76.2 cm)| 26 3/8” (67.0 cm)| 15” (38.1 cm)| 115044
MRV36-ER| 36” (91.4 cm)| 33 3/8” (84.8 cm)| 15” (38.1 cm)| 115086
MRV48-ER| 48” (121.9 cm)| 43 3/8” (110.2 cm)| 10” (25.4 cm)| 115087

IMPORTANT
INSTALLER: To ensure the cooking unit performs properly, seal all seams around the motor cover where it contacts the vent chassis with aluminum tape. (See the graphic below for motor cover location.)

To close the gap between the Range and the Downdraft, install this trim bracket behind the range with the included hardware.

Installation Specifications

Planning the Installationz
General System Layout
The vent system consists of the downdraft vent and a Dacor-approved cabinet blower (MRV3015 and MRV3615), remote blower, or in-line blower. (See Pg. 7).

WARNING

  • Failure to install an approved blower and proper duct-ing will cause a backdraft and poor venting.
  • To reduce risk of personal injury from reaching over a hot appliance, avoid cabinet storage directly above the cooking surface.
  • Follow minimum clearances and installation location in the vent, appliance, and blower instructions. Failure to do so may cause a fire or safety hazard.
  • Plan the installation so minimum dimensions are met or exceeded. All contact surfaces between the downdraft vent and cabinets/walls must be solid and at right angles.
  • The downdraft vent has adjustable anchor legs to accom-modate various cabinet heights.
  • Install the downdraft vent and range/cooktop so they can be removed for service.
  • Allow access from the cabinet front to the chassis, and utilities of the downdraft vent and cooktop for inspection and service. (Drawers/shelves must be removable.)
  • There are 7/8” access holes in the bottom and side of the downdraft vent for connecting blower wiring and strain relief. Wire the blower to turn on when the downdraft vent is turned on. When installing a remote or in-line blower, run the blower wiring/conduit parallel to the duct work, connecting it to the downdraft vent on one end and the blower on the other.
  • Allow room for the exhaust duct coming out of the unit.(See Planning the Duct Work, Pg. 8, for details.) Consider the maximum-allowable duct run when decid-ing the layout. (See Planning the Duct Work, Pg. 8, for details.)
  • See the range/cooktop installation instructions for mini-mum cutout dimensions specific to the downdraft vent being installed.

Cooktop Cabinet/Countertop Cutout – Top View

Range Cabinet/Countertop Cutout – Top View

Example of Layout with Cabinet
Blower Configuration, Exhaust Through Wall

WARNING

  • To reduce risk of fire and to properly exhaust air, duct air outdoors, not into any interior spaces or garages.
  • TO REDUCE FIRE RISK, USE ONLY METAL DUCTING.
  • DO NOT install multiple blowers to lengthen the duct run. Even small differences between blower airflow rates can greatly reduce the downdraft vent’s air draw.

Building codes may require makeup air systems with ven-tilation systems that move air greater than the specified movement rate (CFM). Consult a qualified HVAC specialist when designing the system for the requirements in your area and to assure optimal performance.
You must install a Dacor blower for the downdraft vent to operate properly. See the blower installation instructions for directions. For model CABP3, see the instructions later in this manual.

APPROVED DACOR BLOWERS FOR USE WITH MODEL MRV SERIES DOWNDRAFT VENTS

Dacor Blower| Rating| Compatible Vent
CABP31| 600 CFM2| MRV30153, MRV36153
ILHSF8| 600 CFM4| All
ILHSF10| 1100 CFM4| All
REMP3| 600 CFM4| All
REMP16| 1000 CFM4| All
1Due to a lack of clearance, do not use this blower if installing a range or wall oven in front of the downdraft vent; 2Nominal rating at zero inches static pressure, see the CABP3 blower rat- ings on page 17 for actual rating; 3Revision B and later units only; 4Nominal rating at zero inches static pressure. See blower installation instructions for actual ratings.

For installations with CABP3 blowers

  • Installation requires Dacor adapter kit # AERVCAB.
  • The blower assembly is mounted to the front of the down-draft vent with the exhaust pointing in the desired direc-tion. (See Pg. 10.)
  • The CABP3 blower output connects directly to 3¼ x 10 rectangular ducting.

Installations with ILHSF-/REMP-series blowers

  • The downdraft vent can be configured to exhaust through the back/bottom/sides by removing the proper exhaust knock-out. (See Pg. 9.)
  • When installing an ILHSF blower, minimize noise by installing it as close as possible to the duct-system exhaust. (Minimum recommended distance from the downdraft vent is 5 feet.)
  • When connecting the duct work to the back of the unit, the customer must supply a 3¼ x 10 rectangular transi-tion to make the connection.
  • For side/bottom exhaust connections, use the supplied transition to connect the duct work to the unit. It transi-tions between the unit’s 15/8 x 16 exhaust outlet and a 3¼ x 10 rectangular duct
  • connection. On bottom exhaust installations, cut a hole in the floor so the transition and/or duct work can pass through the floor. (See Pg. 13).

On side exhaust installations, allow 5 in. on the side for the 2 x 16 to 3 ¼ x 10 transition, plus space for the duct attached to it (X).

Installation Specifications

  • Vertical center line of rear exhaust knock out lines up with vertical center line of chassis
  • Bottom Exhaust Knock Out (1 5/8 x 16)
  • On 46” and 48” wide models, the vertical center line of bottom knock- out lines up with vertical center line of chassis
  • On 30” and 36” wide models, the vertical center line of bottom knock- out is offset 3”
  • Side Exhaust Knock Outs (1 5/8 x 16)

Exhaust Knock-out Locations for Use with REMP- and ILHSF-Series Blowers

Duct installation requirements for all blowers

  • All duct work (including screws and duct tape) shall be purchased by the customer.
  • In planning new duct work, always look for the shortest, most direct route to the outside. (See Pg. 7.)
  • You can increase duct size over the duct run if desired. To prevent backdraft, never decrease duct size.
  • Do not rely on duct tape alone to seal joints. Fasten all connections with sheet-metal screws, then tape all joints with certified silver tape or duct tape.
  • Use sheet-metal screws as needed to support the ducting.
  • To avoid backdraft, the duct outlet may required a damper.
  • Ensure duct work does not interfere with joists or studs.
  • With concrete slab construction, “box in” the duct work and blower wiring to prevent crushing or other damage when concrete is poured.
  • Cross-drafts or air currents from adjacent open windows or doors, heating-/air-conditioning outlets, ceiling fans, and recessed ceiling lights reduce vent efficiency.
  • System exhaust location (Pg. 8) must account for snow buildup where applicable.

Exhaust Locations/Dimensions for CABP3 Cabinet Blower Installations
(MRV3015, MRV3615)

Exhaust Locations and Side Dimensions for CABP3 Cabinet blower

Model A B C
MRV3015 12 1/8” (30.7 cm) 5 5/8” (14.4 cm) 1 3/4” (4.4 cm)
MRV3615 9 3/4” (24.8 cm) 8” (20.3 cm) 4 1/4” (10.8 cm)

Calculating Maximum Duct Run Length

  • For best performance, consult a qualified HVAC specialist when designing the duct system.
  • Do not use duct work that is smaller than the required sizes in the tables below.
  • For best performance, keep the duct run as short as pos-sible, and never exceed the maximums in the table in the Duct Work Design Tips section.
  • The max. duct length for the downdraft vent depends on the blower used, and number of elbows and transitions. The Equivalent Number of Feet for each elbow and transition must be subtracted from the maximum straight length to compensate for wind resistance. To decide the maximum allowable length of the ducting, subtract all equivalent lengths of the elbows and transitions listed below from the Blower Maximum Duct Straight Length. Example: For a downdraft vent system using a 3¼ x 10 rectangular duct, two (2) 3¼ x 10 90° elbows, a 3¼ x 10” rectangular to 10” round transition, and a

REMP16 remote blower

  • From the Blower Maximum Duct Straight Length table, the max length without transitions and elbows is 60 ft.
  • The equivalent length of each 90° elbow is 15 ft.
  • The equivalent length of 45° elbow is 2 ft.
  • The equivalent length of the transition is 4 ft.
  • The total equivalent length of the above parts is : 15 ft + 15 ft + 4 ft + 2 ft = 36 ft.
  • The max amount of straight duct that can be used with a REMP16 and the above parts is: 60 ft – 34 ft = 24 ft.

Equivalent Number of Feet (Nominal) – Duct Elbows and Transitions

45° elbow/8”| 3 ft| 3¼ x 10/45° elbow| 7 ft
45° elbow/10”| 2 ft| 3¼ x 10/90° elbow| 15 ft
90° elbow/8”| 7 ft| 3¼ x 10/90° flat elbow| 20 ft
90° elbow/10”| 5 ft| 3¼ x 10 to

8” round transition

| 4 ft
90° 3 ¼ x 10 to

8” round transition

| 25 ft| 3¼ x 10 to

10” round transition

| 4 ft
Roof cap| *| Wall cap|
Equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVAC specialist;
Not applicable to REMP blowers.

Duct Work Design Tips

  • Reduce transitions and turns to the fewest sharp angles. Two staggered 45° angles are better than one 90°. Keep turns as far from the hood exhaust as possible, with the most possible space between each bend.
  • For best performance, use round ducting when possible, especially when elbows are required.
  • If multiple elbows are used, try to keep a minimum of 24” of straight duct between them. Avoid “S” or “back to back” configurations of adjacent elbows.
  • Do not use flexible metal ducting.
Blower Blower Maximum Duct Straight Length
8” Duct 10” Duct
CABP3 40 ft (12.2 m)
ILHSF8 50 ft (15.2 m)
ILHSF10 60 ft (18.3 m)
REMP3 50 ft (15.2 m)
REMP16 60 ft (18.3 m)

Installation Preparation

Verifying Package Contents

  1. Unpack the unit, and verify that all items on the parts list are present. Notify your dealer immediately if anything is missing. Do not install a damaged or incomplete appli-ance. The customer must report cosmetic issues within 30 days of installation.
    Parts List

    • Product literature
    • Anchoring legs (left – PN 36861, right – PN 36862)
    • 2 wood screws, #14 x 2 1/2 (PN 83047)
    • 3 wire nuts
    • 1 5/8 x 16 to 3 ¼ x 10 duct transition (PN 13768)
    • 2 sheet metal screws, #10 x 1/2 (PN 83022)
    • 2 keps nuts, 1/4-20 (PN 83049)
    • 2 flat washers, 1/4-20 (PN 83203)
    • Insulation foam (tape)

Installation with CABP3 blower requires Dacor adapter kit # AERVCAB. Kit includes adapter, wiring diagram label (PN 106770), 3 wing nuts (PN 83035), 3 flat washers (PN 83008) and 6 lock washers (PN83340).

WARNING

  • If the electrical outlet does not meet the Electrical Specifications on Pg. 2, postpone the installation until a licensed electrician install the proper outlet.
  • Install the vent vertically only.
  • Do not enlarge or modify the exhaust knock-outs. Cut an exhaust hole on the chassis only as shown to pre-vent an increase in noise and compromised function.

NOTE: The downdraft vent installs in the back of the cut-out, separate from the range or cooktop. Install the down-draft vent before installing the range or cooktop.

  1. Start by loosely attaching the anchoring legs to the studs on the left and right sides of the downdraft vent using the provided Keps nuts and washers.

Installation Preparation: Downdraft Vent
With ILHSF-/REMP-Series Blower

NOTE: For units using the CABP3 cabinet blower, skip to Installation Preparation for Downdraft Vent with CABP3 Cabinet Blower, on facing page.

  1. Remove the appropriate side or bottom exhaust knockout (depending on the desired exhaust configuration) from the downdraft vent chassis by cutting the metal cross overs and removing the insert.
  2. Cut and remove the foil material inside the knock-out hole or the vent will not work.
    • If the unit will vent through the bottom or side, install the suppled 15/8 x 16 to 3¼ x 10 transition to the exhaust location. Before installing, peel the protective backing off the foam tape, and apply
    • it to the transition flanges. Attach the transition with the provided sheet metal screws (see below).
    • If the unit will vent through the back, attach a 3 ¼ x 10 duct to the vent hole created by removing the knock-out on the back of the unit.
  3. See Installing the Downdraft Vent in the Cutout, Pg.
  • Adapter Installation: CABP3 Blower
  • (Optional: MRV3015, MRV3615)
  1. Remove the front cover so the AERVCAB cabinet blower adapter can be installed. Remove and retain the 3 wing nuts and 3 flat washers on the front of the unit. Discard the 3 lock washers (which will be replaced). Tilt the cover out and pull up to remove it.
  2. Peel the backing off of some of the foam tape included with the adapter. Attach it to the right and left flanges.
  3. Hold the adapter in front of the opening, located on the front of the unit with the adapter’s studs on top, and all flanges closest to the downdraft vent chassis.
  4. Slide the adapter’s bottom into the bottom retainer bracket on the downdraft vent at an angle. Attach the adapter using the 3 wing nuts and flat washers removed in Step 1 and 3 of the lock washers from the adapter kit.

Installing the Downdraft Vent in the Cutout

  1. Cut a hole in the cabinet so the ducting can pass to the floor/wall for the planned ducting layout. Use the dimensions on pages 9, 10 to decide the hole center line locations. If using the 2” x 16” to 3 1/4” x 10” transi-tion (REMP and ILHSF blower installations), the hole may need to be enlarged slightly.
  2. Gently slide the vent into the rear of the countertop cut-out with the electrical access panel toward the front.
  3. Adjust the anchoring leg height so that the top of the downdraft vent rests on the counter, then tighten the hex nuts. Secure the anchoring legs to the cabinet floor with the provided wood screws.

Cabinet Blower Installation
(Optional: MRV3015, MRV3615)

  1. Find the wiring diagram label included with the adapter kit. Remove the protective backing, and place it over the existing label on the CABP3 blower as shown.
  2. Find the foam tape supplied with the downdraft vent. Place the blower on the floor as it will be mounted on the front of the downdraft vent. Remove the backing from the foam tape, and attach it to the right and left flanges of the blower base plate.
  3. With the exhaust oriented as desired, slide the bottom flange of the CABP3 blower base plate behind the tab on the bottom of the adapter mounted to the front of the downdraft vent.
  4. Cover the adapter opening by pushing the blower against it. Ensure the foam tape creates a good seal on the right and left side of the opening. Center the blower base plate horizontally over the adapter’s front opening.
  5. Install the adapter top retainer bracket over the blower base plate flange. Secure it with the 3 wing nuts, lock washers, and flat washers included with the adapter.

ILHSF or REMP Series Blower Installation
If using a ILHSF or REMP series blower, install it according to the blower installation instructions.

Duct Work Installation

WARNING
For best performance and to keep smoke, odors, and combustion byproducts from entering the home, tape all duct joints securely.
Install the duct work per the Installation Specifications section. Use sheet- metal screws and duct tape to connect and seal all pieces. Support the duct weight as needed to ensure sealed joints.

Electrical Installation

WARNING: ELECTRIC SHOCK HAZARD

  • Plug in the downdraft vent after installation is complete.
  • Follow the wiring diagram carefully. Do not change the factory-wired terminal connections inside the electrical-access panel for the downdraft vent or blower.
  • Route wiring away from hot surfaces.
  1. For ILHSF and REMP blower installations, run the wiring/conduit line used to supply power from the downdraft vent to the blower parallel to the duct work.
  2. Remove the cover from the downdraft vent electrical-access panel.
  3. Connect the wiring/conduit to the blower as shown on pgs. 15 and 17 per local ordinances. Ensure all terminal connections (including factory-wired connections) are tight. Replace the electrical-access panel.

Range/Cooktop Installation
Install the range or cooktop as instructed.

Electrical Installation – CABP3 Cabinet Blower
Downdraft Vent Electrical Access Panel

Verifying Proper Operation

WARNING

  • Read the downdraft vent user manual completely before operation.
  • Install all front filters before operating the downdraft vent. (See the user manual about filter installation.)

CAUTION
Before plug-in, route the downdraft-vent power cord away from range or cooktop surfaces.

  1. Ensure the power switch atop the downdraft vent is in the up position.
  2. Plug in the downdraft vent.
  3. Press the power switch to raise the vent.
  4. Once raised, the vent should begin to draw air. Turn the variable-speed control switch in both directions to verify that the system operates correctly.
  5. Press the top cap up/down switch to lower the vent.
  6. Ensure the vent top cap does not catch on the back edge of the cooktop/range. If it does catch, reposition the cooktop/range to avoid permanent vent damage.

If the downdraft vent is not functional after installation

  • Ensure power is supplied to the downdraft vent.
  • Ensure the downdraft vent supplies power to the blower.
  • If the vent will not raise properly or makes a scraping sound, check for under-counter obstructions.

If the downdraft vent fails to function after performing the above checks, do not try to repair it yourself. Contact Dacor Customer Assurance: 833-353-5483. Have available all vent and blower model/serial numbers from the product data labels when you call.
Dacor is not financially responsible for correcting prob-lems due to faulty installation.

Installation Checklist

  • Are the anchor legs tightened in place? Is the unit level?
  • Is the duct work completely installed and all joints attached with sheet-metal screws and wrapped with duct tape?
  • Are both ends of the blower power cable connected (to the downdraft vent and the blower itself)?
  • Are the vent filters installed per user manual instructions?Is the power cord routed away from the hot range/cooktop surfaces.
  • Is the unit connected to an electrical outlet that meets the electrical specifications in these instructions?
  • Was proper operation verified?
  • Was the warranty activated online or the warranty card filled out and mailed?

Technical Data

Wiring Diagram: All Models

CABP3 Cabinet Blower Ratings

**CABP3 Cabinet blower Airflow***

Nominal| 600 CFM
Actual| 585.6 CFM

  • At zero inches static pressure. Performance varies based on duct system configuration.
  • Electrical Rating: 4 Amps. @ 120 Vac, 60 Hz.
  • For ILHSF or REMP series blower ratings, see the blower installation instructions.