Product Information
The product is a fixture that requires mounting and assembly. It comes with a mounting plate (M), a backplate (B), a shade (2), a socket ring (4), and a bulb (1). The fixture is designed for indoor use and has specific wiring and grounding instructions outlined in the user manual. The product is manufactured by LARK and the address is 33000 Pin Oak Parkway, Avon Lake, OH 44012.
Product Usage Instructions
Mounting Instructions
-
Find a clear area in which you can work.
-
To mount the fixture, first release the mounting plate (M) by removing the screws (S).
-
Secure the mounting plate (M) to the junction box (J) using screws (C) (not provided).
-
Make wiring connections using IS-18 on the next page.
-
Secure the backplate (B) to the mounting plate (M) using the previously removed screws (S).
Assembly Instructions -
Place the shade (2) over the socket.
-
Use the socket ring (4) to secure the shade (2).
-
Install an appropriate medium base bulb (1) into the lamp fixture.
-
The fixture can now be powered on.
Note: Before installation, it is important to read and follow the wiring and grounding instructions provided in IS-18. It is also recommended to turn off the power supply during installation. If new wiring is required, consult a qualified electrician or local authorities for code requirements.
Mounting Instructions
start here
-
Find a clear area in which you can work.
-
Unpack fixture and glass from carton.
-
Carefully review instructions prior to assembly.
-
To mount fixture first release mounting plate (M) by removing screws (S)
-
Secure mounting plate (M) to junction box (J) using screws (C) (not provided)
-
Make wiring connections using IS-18 on the next page
-
Secure backplate (B) to mounting plate (M) using the previously removed screws (S)
Drawing 1 -
Place shade (2) over socket
-
Use socket ring (4) to secure shade (2)
-
Lamp fixture with appropriate medium base bulb (1)
-
Fixture can now be powered on
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY
ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW
WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR
CODE REQUIREMENTS.
Make electrical connections from supply wire to fixture lead wires. Refer to
instruction sheet (I.S. 18) and follow all instructions to make all necessary
wiring connections. Then refer back to this sheet to complete installation of
this fixture.
Wiring Grounding Instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS
Wiring Instructions
Indoor Fixtures
- Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
- Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
- Please refer to the grounding instructions below to complete all electrical connections
Outdoor Fixtures
-
Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3.
-
Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
-
Cover open end of connectors with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially. -
Please refer to the grounding instructions below to complete all electrical connections.
Grounding Instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground
wire (E) (typically copper or green plastic coated) to the fixture mounting
strap (M) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two
mounting screws in strap. Any remaining tapped hole may be used for the ground
screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under
the head of the ground screw (S) on fixture mounting strap (M) and connect to
the loose end of the fixture ground wire directly to the ground wire of the
building system with appropriately sized twist-on connectors – see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to
power supply ground with appropriately sized twist-on connector inside post.
Cover open end of connector with silicone sealant to form a watertight seal –
see Drawing 3.