Description

The Tempo Communications 180XL Visual Fault Locator is used to visually locate loss locations such as Macro bends, bad connectors, and other fiber discontinuities. Fiber continuity can also be visually confirmed.

Safety

Safety is essential in the use and maintenance of Tempo tools and equipment. This instruction manual and any markings on the tool provide information for avoiding hazards and unsafe practices related to the use of this tool. Observe all of the safety information provided.

Purpose of this Manual

This manual is intended to familiarize all personnel with the safe operation and maintenance procedures for the Tempo Communications 180XL Visual Fault Locator.

Keep this manual available to all personnel.

Package Contents

  • 1 Visual Fault Locator
  • 2 AA Batteries
  • 1 Instruction manual
  • 1 Soft carry case

Important Safety Information

CAUTION

LASER LIGHT
DO NOT STARE INTO BEAM 1 mW max at 640-660 nm CLASS 2 LASER PRODUCT

WARNING

Do not look directly into the output port when the instrument is ON. Never use a viewing instrument such as a magnifier or microscope to view the free end of any optical fiber connected to the 180XL. The use of viewing on active fibers can focus an intense laser beam onto the retina of the eye, resulting in permanent damage or blindness.

Always aim the free end of an active fiber at a nonreflective surface.

Users should always cover the output port with the dust cap when the instrument is not in use.


Do not discard this product or throw away!

For recycling information, go to www.TempoCom.com.

All specifications are nominal and may change as design improvements occur. Tempo Communications shall not be liable for damages resulting from misapplication or misuse of its products.

Operation

  1. Slide the switch to first position (MOD) to place the 180XL in modulation mode. The green LED will flash indicating modulation mode.
  2. Slide the switch to the next position (ON) to set the VFL to CW mode. The green LED will indicate CW mode by remaining on all of the time.
  3. When the LED flashes red, the batteries are low and must be replaced.

Applications

Continuity check
Continuity check
Break in fiber
Break in fiber
Macro bend loss
Macro bend loss
Dirty connectors
Dirty connectors

The 180XL Visual Fault Locator is designed to quickly locate breaks in optical fibers. Any interruption in continuity will be indicated by red light escaping from the fiber. Light can also escape from the fiber if it is stressed or bent too tightly. In either case, escaping light is a sure sign of a problem.

Cleaning the Output Port

Clean all connectors before inserting them into the 180XL optical port.

For optimal performance it is also recommended that the user routinely cleans the optical port.

To clean the 180XL optical port, insert a Tempo 946 cleaning wand into the output port until it stops.
Twist the wand, remove it, and discard. Do not reuse the cleaning wand.

Users should always cover the output port with the dust cap when the instrument is not in use.

Note: Do not blow air into the output port to remove dirt particles. Doing so will only pack the dirt and make it harder to remove.

Specifications

Wavelength 650 nm ±10 nm
Emitter Type Fabry Perot
Maximum Output Power 0 dBm (1 mW)
Range 7 km
Laser Classification Class 2
Modes of Operation CW and 2 Hz modulation
Method of Display Operation Green/Red LED
Fiber Type Single mode, multimode
Connector Interface 2.5 mm universal, optional 1.25 mm adapter
Battery AA (2)
Battery Life 80 hours with 3.9 Wh batteries
Weight (without batteries) 70 g (0.15 lb)
Dimensions 180 mm x 23 mm (7.08″ x 0.91″) dia.
Operating Temperature -10 °C to +45 °C (14 °F to 113 °F)
Storage Temperature 40 °C to +70 °C (-40 °F to 158 °F)
Certifications CE, FCC, CDRH, EAC

Visitez le site www.TempoCom.com pour le manuel d’instructions en Français.

Visite www.TempoCom.com para manual de instruções em Português

Die deutsche Bedienungsanleitung finden Sie auf www.TempoCom.com

Посетите сайт www.TempoCom.com для получения руководства по эксплуатации на русском языке

Para obtener el manual de instrucciones en español visita www.TempoCom.com

Per ottenere il manuale d’istruzione in Italiano, vsita il sito www.TempoCom.com

1390 Aspen Way • Vista, CA 92081 • USA 800-642-2155
Tempo Europe Ltd. • Brecon House, William Brown Close Cwmbran, NP44 3AB, UK
Tel: +44 1633 927 050
www.TempoCom.com

TEMPO Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals