KV2 Audio EPAK2500R Four Way Modular User Guide
- June 13, 2024
- KV2 audio
Table of Contents
KV2 Audio EPAK2500R Four Way Modular
Product Information
- Product Name: EPAK2500R
- Manufacturer: KV2 Audio
Description: The EPAK2500R is an amplifier designed to provide a true dynamic representation of the source audio, eliminating distortion and loss of information. It is a high-powered device capable of producing high voltages and sizeable currents.
Important Safety Instructions:
- Keep this manual for future reference.
- Heed all warnings.
- Follow all instructions.
- Do not use this unit near water. Do not spill water or other liquids into or on the unit. Do not operate the EPAK2500R while wet or standing in liquid.
- Clean only with a dry cloth.
- Do not block the air intake or exhaust ports. Install the unit in accordance with the instructions.
- Do not operate the EPAK2500R near heat producing devices such as radiators, heat registers, stoves, or other apparatus that produce heat.
- Always operate the unit with the chassis ground wire connected to the electrical safety earth. Do not defeat the grounding feature.
- CAUTION: To reduce the risk of electric shock, do not remove the cover. No user-serviceable parts inside. Refer servicing to qualified personnel.
- WARNING: To prevent fire or electric shock, do not expose this equipment to rain or moisture.
Product Usage Instructions
Unpacking:
To unpack the EPAK2500R, remove it from its packaging and ensure all included
accessories are present.
Rack Mounting:
The EPAK2500R is designed to be mounted in standard 19-inch rack systems.
Use the integral rear mounting rack ears for additional support. Do not rely
on fixing and mounting the EPAK2500R using just the front panel as support.
Use eight screws and washers to mount the amplifier to the equipment rack
rails (four for the front and four for the rear). It is recommended to use a
shock-mounted rack for touring use to prolong the life of the EPAK2500R.
Cooling:
The EPAK2500R features a comprehensive cooling system with chassis-sealed PCB
board mounting and shock-mounted, speed-controlled fans. This ensures that the
cooling system does not drive air across PCB boards, connectors, or
components, thereby prolonging electronic component lifespan and minimizing
maintenance cycles. Air is drawn into the front of the amplifier by the two
fans on the rear panel, passes over the cooling fins of the heat sinks, and
exhausts through the rear. If the heat sink gets too hot, its sensing circuit
will open the output relay, disconnecting the load.
The Future of Sound.
Made Perfectly Clear.
At KV2 Audio our vision is to constantly develop technologies that eliminate
distortion and loss of information providing a true dynamic representation of
the source.
Our aim is to create audio products that absorb you, place you within the
performance and deliver a listening experience beyond expectations.
IMPORTANT SAFETY INSTRUCTIONS
Before using your EPAK2500R, be sure to carefully read the applicable items of these operating instructions and the safety suggestions
-
Keep this manual for future reference.
-
Heed all warnings.
-
Follow all instructions.
-
Do not use this unit near water. Do not spill water or other liquids into or on the unit. Do not operate the EPAK2500R while wet or standing in liquid.
-
Clean only with dry cloth.
-
Do not block the air intake or exhaust ports. Install the unit in accordance with the instructions.
-
Do not operate the EPAK2500R near heat producing devices such as radiators, heat registers, stoves or other apparatus that produce heat.
-
Always operate the unit with the chassis ground wire connected to the electrical safety earth. Do not defeat
the safety purpose of a grounding-type plug. A grounding type plug has two pins and a third grounding prong. The third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. -
Connect only to AC power outlets rated 115-250V, 50-60Hz.
-
Do not use this EPAK2500R if the power cable is broken or frayed. Protect the power cable from being walked upon or pinched particularly at the plugs and the point where it exits from the apparatus.
-
Only use accessories specified by the manufacturer.
-
The unit is intended to be used in a 19″ rack. Follow the mounting instructions. When a rack on wheels is used, use caution when moving the loaded rack to avoid injury from tipping over.
-
Unplug this apparatus during lightning storms or when unused for long periods of time.
-
Do not connect an EPAK2500R output in parallel or series with any other EPAK2500R’s output. Do not connect the EPAK2500R output to any other voltage source, such as battery, mains source, or power supply, regardless of whether the EPAK2500R is turned on or off.
-
Do not run the output of any EPAK2500R back into another channel’s input.
-
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way such as:
- Power-supply cord or plug is damaged
- Liquid has been spilled into the unit
- An object has fallen into the unit
- The unit has been exposed to rain or moisture
- The unit does not operate normally
- The unit was dropped or the enclosure is damaged
-
Do not remove top or bottom covers. Removal of the cover will expose hazardous voltages. There are no serviceable parts inside and removal may void the warranty.
-
An experienced user shall always supervise this professional audio equipment, especially if inexperienced adults or minors are using the equipment.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER.
NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.
WARNING: To prevent fire or electric shock, do not expose this equipment
to rain or moisture.
Application
Specifically designed as the amplification and control elements for the ES
loudspeaker systems in a full rack mount module
- Portable PA
- Fixed installations
- Bars and Nightclubs
- Houses of Worship
Introduction
Rack mount version of our popular EPAK2500 four-way, active control and amplification unit specifically designed for the ES Series modular loudspeaker system. Two shock mounted fans move air across the heatsinks which seal and protect the electronic components. This minimizes maintenance cycles and improves the components lifespan and reliability. Both the EPAK2500 and EPAK2500R utilize KV2’s industry leading 20MHz sampling for on board time alignment and phase correction of all components in the ES system.
The amplifier compliment inside the EPAK2500R is as follows:
- High Frequency – 100-watt, Class AB, push pull, low intermodulation design.
- Mid Frequency – 200-watt, Class AB, push pull, low intermodulation design.
- Mid Bass – 600-watt, high-efficiency, current-enhancing switch mode technology with Linear Active Filter.
- Subwoofer – 1600-watt, high-efficiency, current-enhancing switch mode technology with Linear Active Filter.
The EPAK2500R is “Line Driver Ready” and has its own input impedance selector
switch on the rear panel to accurately match up the input impedance to the
output of any mixer used. In most cases it would be advisable to use a VHD LD4
line driver in addition at the mixer end to ensure that the line to the
amplifier is driven correctly and the signal integrity maintained.
Although this unit is simple to operate improper use can be dangerous. This is
a very high-powered device that can put out high voltages and sizeable
currents. Always use safe operating techniques with the EPAK2500R.
FOR YOUR SAFETY, READ THE IMPORTANT PRECAUTIONS SECTION AS WELL AS THE INPUT,
OUTPUT
AND POWER CONNECTION SECTIONS OF THIS MANUAL.
Unpacking
Unpack the EPAK2500R and check to see if there is any damage to it. If you
find any damage notify your supplier immediately. Only the consignee may
institute a claim with the carrier for damage incurred during shipping. Be
sure to save the carton and all packing materials for the carrier’s
inspection.
Should you ever need to ship the unit, only use the original factory
packaging. If the shipping carton is unavailable, contact your supplier to
obtain a replacement.
The EPAK2500R carton should contain:
- EPAK2500R amplifier control unit
- User’s manual
- PowerCon detachable power cable
- ES Cable Kit – KVV987047 (contains 2pcs LF15, 1pc LF40, 1pc MH60 cables)
Rack Mounting
EPAK2500R’s will mount in standard 19″ rack systems. Integral rear mounting
rack ears are also provided for additional support, do not rely on fixing and
mounting the EPAK2500R using just the front panel as support. Use eight screws
and washers to mount the amplifier to the equipment rack rails (four for the
front and four for the rear).
We recommend using a shock mounted rack for touring use to prolong the life of
your EPAK2500R.
Cooling
The EPAK2500R has a comprehensive cooling system featuring chassis-sealed PCB
board mounting and shock mounted, speed controlled fans. This means that the
cooling system never drives air across PCB boards, connectors or components
ensuring prolonged electronic component lifespan and minimizing maintenance
cycles.
Air is drawn into the front of the amplifier by the two fans on the rear
panel, this passes over the cooling fins
of the heat sinks and exhausts through the rear. If the heat sink gets too
hot, its sensing circuit will open the output relay, disconnecting the load.
It is important to have an adequate air supply at the front of the amplifier,
and enough space around the rear
of the amplifier to allow the cooling air to escape. If the unit is rack
mounted, do not use doors or covers on the rear of the rack; the exhaust air
must flow without restriction. If you are using racks with closed backs, use
fans on the rear rack panel to ensure an ample air supply.
IMPORTANT! Please note that for correct full performance of the unit AND ANY
WARRANTY COVER,
it is important that regular maintenance of the front vents and filters as
well as the rear panel fans be inspected and cleaned by removing any dust and
debris build-up. Any product failure due to lack of attention in this matter
will immediately void any current warranty. (Please refer to notes re
ventilation procedures).
AC Requirements
A PowerCon cable is provided to connect the EPAK2500R to a suitable AC power
supply.
The PowerCon is a connector without breaking capacity, i.e. the PowerCon
should not be connected
or disconnected under load or while it is live. Always isolate your AC supply
before disconnecting the PowerCon connector.
Your EPAK2500R will be supplied pre set to the voltage used in your area. The
table below provides typical current draw figures for the EPAK2500R.
AC Input| Current draw with amplifier running at Average
Power (Each Channel)| Current draw with amplifier running at
Peak Power (Each Channel)
---|---|---
250V| 8.25A| 12.5A
230V| 9A| 14A
115V| 18A| 28A
Front panel
-
AC Mains Switch
The EPAK2500R has a combination AC Mains switch/circuit breaker on the front panel. If the switch shuts off during normal use, push it back to the ON position once. If it will not stay on you should take the unit to qualified service personnel to have it serviced. -
Unproper Use LED
If the EPAK2500R is connected improperly then this LED will light and the unit will shut down. -
Limit / Thermal LED
This is a dual colour LED, when yellow it indicates that the audio limiter has been activated. When red it indicates that the thermal limit of the EPAK2500R has been exceeded and the unit has shut down because of this. -
Power / Service LED
This is a dual colour LED, when green it indicates that the AC power is on. When red it indicates that there is a fault condition sensed within the EPAK2500R and that the unit needs servicing. -
Signal Present
This green LED indicates when audio signal is present at the EPAK2500R’s input. -
Sub Set Up
This switch is set according to which combination of subwoofers is being used with the system. Refer to ‘Using the System’ for further information, the various combinations are listed in the table within this section. -
Hi Freq Level
This controls the output level of the high frequency amplifier to enable you to adjust the high frequency component of the ES system to the desired level. -
ES1.0 System
This switch sets the controller for use when either a single ES1.0 is being used or a double system using 2 ES1.0’s are being used. In this mode another EPAK2500R would be required to power the second ES1.0 and both switches should be set to ‘Double’. -
Master Level
This is the master level control for the system and will affect both the ES1.0 and the subwoofer outputs. -
Ext Sub Level
This is the level control for the External Sub output; it is ‘post’ the Master Level control. -
Sub Level
This is the level control for the Internal Sub output; it is ‘post’ the Master Level control.
Rear panel
-
Main Input / Through Signal Out
This is the main system input connector with associated ‘Through Signal Output’ connector for sending unprocessed signal to other devices, such as more EPAK2500R’s to power more ES1.0’s in a system. -
Input Z
This switch selects one of two input impedance settings for the EPAK2500R. The switch should be set to the 50Ω setting when a single EPAK2500R is driven from a VHD LD4 line driver. Where an LD4 is not being used and the EPAK2500R is being driven from a standard mixing console output, then the 10kΩ setting should be used. If two EPAK2500R units are linked via their signal from a Line Driver, then only the last EPAK2500R in the signal chain should be set to 50ohm. -
Mid/High In / Pre Control Out
This is an insert point for the Mid/High section of the EPAK2500R, the signal sent to the ES1.0 cabinet. It enables you to ‘insert’ an external device (a delay line for example) into the signal that is being sent to the ES1.0. With the associated switch in the ‘Engage’ setting the Pre Control Out connector would send the signal to the external device, and its output would be returned into the Mid/High In connector. -
Internal Sub In
This ‘insert’ point allows you to drive the internal subwoofer amplifier from an external source. The signal for the internal subwoofer amplifier is usually derived from the Main Input on the EPAK2500R but with this Sub In and associated switch the option is available to derive the signal input for the internal subwoofer section from a different source. For further information see ‘Using the System’. -
External Sub In, External Sub Out
Apart from providing signal processing and power amplification for driving the ES1.0 enclosure and ES subwoofers the EPAK2500R also provides processed outputs for feeding VHD3200 subwoofer amplifiers to drive various combinations of ES and VHD subwoofers. The signal for this is usually derived from the Main Input on the EPAK2500R but with these Sub In and Sub Out connectors and associated switch the option is available to derive the signal input for the external subwoofer section from a different source. For further information see ‘Using the System’. -
PowerCon Power Connector
Accepts a standard PowerCon terminated AC cable. -
Fans
The cooling fans operate continuously while the EPAK2500R is on. An internal temperature sensor increases the speed of the fans during high temperature conditions. Air enters through the front grille and exits through the rear. Be sure to allow adequate air flow to the front of the rack in which the EPAK2500R is mounted. -
ES1.0 AP6 Connector
Accepts a standard AP6 terminated loudspeaker cable for connecting up to a single ES1.0 cabinet. We recommend using 2.5 mm/core cables. -
Internal Sub AP4 Connector
Accepts a standard AP4 terminated loudspeaker cable for connecting up to various ES series subwoofers. We recommend using 2.5 mm/core cables.
Minimum load impedance is 4Ω !
Normal Set Up
The EPAK2500R is designed to actively power one ES1.0 cabinet and associated
subwoofer systems. For Normal Mode operation signal is applied to the ‘Main
Input’ connector and all the ‘Insert’ switches would be in the ‘Disengage’
position.
The Input Z switch should be set to match the output impedance of the device
feeding the EPAK2500R. If you are using a VHD LD4 Line Driver then the Input Z
switch on the EPAK2500R should be set to 50Ω. If when using the LD4 you are
feeding more than one EPAK2500R then they should all be set to 10kΩ with the
last one in the signal chain set to 50Ω.
Six different combinations of subwoofers are accommodated for when using the
EPAK2500R.
The combinations are as follows:
EPAK2500R Setting | Internal | External |
---|---|---|
Setting 1 | 1 x ES1.8 + 2 x ES1.5 1 | 1 x ES1.8 + 2 x ES1.5 1 |
Setting 2 | 2 x ES1.5 2 | 2 x ES1.5 2 |
Setting 3 | 2 x ES1.8 | 2 x ES1.8 |
Setting 4 | 1 x ES2.5 | 1 x ES2.5 |
Setting 5 | 1 x ES2.5 | 2 x ES1.8 |
Setting 6 (5-way system) | 1 x ES2.5 | 2 x VHD1.21 3 |
Notes on Subwoofer Combinations
- Setting 1 is set up for driving 1 x ES1.8 + 2 x ES1.5. It can also drive 1 x ES1.8 + 1 x ES1.5, in this mode the relevant Sub level control (either Internal or External) should be increased by up to +6dB.
- Setting 2 is set up for driving 2 x ES1.5. It can also drive 3 x ES1.5, in this mode the relevant Sub level control (either Internal or External) should be decreased by -3dB. This setting can also drive just 1 x ES1.5 with the relevant Sub level control adjusted accordingly, dependent on the application.
- Setting 6 is a true 5-way setting. The ES2.5’s are actively crossed over with the VHD1.21’s.
ES Subwoofers Impedances
Subwoofer | Impedance |
---|---|
ES1.5 | 16Ω |
ES1.8 | 8Ω |
ES2.5 | 4Ω |
ES2.6 | 8Ω |
VHD1.21 | 8Ω |
Normal Set Up
The EPAK 2500R is designed to actively power one ES1.0 cabinet and associated
subwoofer systems. Subwoofers are connected in parrallel, the total minimum
impedance load should not be lover than 4Ω.
‘Internal’ denotes subwoofers powered by the internal subwoofer amplifier.
Normal Set Up With Additional Subwoofers
To power more subwoofers, use aditional subwoofer amplifier – VHD3200.
Use External Sub Out signal output for feeding VHD3200 subwoofer amplifiers.
‘Internal’ denotes subwoofers powered by the internal subwoofer amplifier.
‘External’ denotes subwoofers powered by an external VHD3200 subwoofer
amplifier, fed from the EPAK2500R’s External Sub Out connector.
Using the Internal Sub In Insert
The Internal Sub Insert point gives you the ability to ‘insert’ a signal
processing device into the ES Sub signal chain. For instance in some instances
it may be necessary to ‘delay’ the signal going to the ES Sub using a delay
line. The Main Input is used as the system input, as per Normal Mode, but the
Internal Sub In insert switch is switched to ‘Engage’.
A feed is taken to the delay line from the ‘Pre Control Out’ connector and the
return from the delay line is connected to the ‘Internal Sub In’ connector as
per the diagram:
‘Internal’ denotes subwoofers powered by the internal subwoofer amplifier.
‘External’ denotes subwoofers powered by an external VHD3200 subwoofer
amplifier,
fed from the EPAK2500R’s External Sub Out connector.
Using the Mid/Hi Insert
The Mid/Hi Insert point gives you the ability to ‘insert’ a signal processing
device into the ES1.0 signal chain.
For instance in some instances it may be necessary to ‘delay’ the signal going
to the ES1.0 using a delay line. The Main Input is used as the system input,
as per Normal Mode, but the Mid/Hi insert switch is switched to ‘Engage’. A
feed is taken to the delay line from the ‘Pre Control Out’ connector and the
return from the delay line is connected to the ‘Mid/Hi In’ connector as per
the diagram:
Feeding the Subwoofers from another source
Taking the following diagram as an example, if the ES1.0 was flying you might
want to fly one ES2.5 above it with the other two ES1.8’s ground stacked
beneath. In this instance it would be preferable to have both sets of
subwoofers fed by separate feeds from the mixing console, to give you
independent level control to each of the subwoofer types, and to have the
ES1.0 fed by the main output from the mixing console:
‘Internal’ denotes subwoofers powered by the internal subwoofer amplifier.
‘External’ denotes subwoofers powered by an external VHD3200 subwoofer
amplifier,
fed from the EPAK2500R’s External Sub Out connector.
The table below shows the various combinations of the Sub Insert switches and
their effect on the signal routing in the EPAK2500R:
Internal Sub Insert Switch Position| External Sub Insert Switch
Position| Internal Sub Signal derived from| External Sub Signal
derived from
---|---|---|---
Disengage (Out)| Disengage| Main Input| Main Input
Engage (In)| Disengage| Internal Sub In| Internal Sub In
Engage| Engage| Internal Sub In| External Sub In
Disengage| Engage| Main Input| External Sub In
Specifications
High Frequency Amplifier Specification
- Type Class AB Push-Pull low inter-modulation Mosfet design with transformer balanced output
- Rated Continuous Power 100W
- Distortion <0.05%
- Operating Bandwidth 2.5kHz to 28kHz
Mid Frequency Amplifier Specification
- Type Class AB Push-Pull low inter-modulation Mosfet design with transformer balanced output
- Rated Continuous Power 200W
- Distortion <0.05%
- Operating Bandwidth 500Hz to 2.5kHz
Mid-Bass Frequency Amplifier Specification
- Type High efficiency, Low frequency, Current-enhancing switch
- mode
- Rated Continuous Power 600W
- Distortion <0.05%
- Operating Bandwidth 130Hz to 500Hz
Low Frequency Amplifier Specification
- Type High efficiency, Low frequency, Current-enhancing switch
- mode
- Rated Continuous Power 1600W
- Distortion <0.05%
- Operating Bandwidth 20Hz to 130Hz
Signal Input
- Input Sensitivity 1.0V RMS
- Input Impedance 20kΩ (balanced) or 50Ω “Line Driver ready”
Speaker Output
- Speaker Output AP6 (Mid-Hi), AP4 (Sub)
Power
- Power Connector Neutrik PowerCon®
- Operating Voltage Range 100 to 120V@60Hz | 205 to 240V@50Hz | 225 to 260V@50Hz
- Recommended Amperage 20A 115V | 10A 230V | 10A 250V
Physical Dimensions
- Height 177 mm (6.96″)
- Width 481.4 mm (18.95″)
- Depth 415.4 mm (16.35″)
- Weight 30 kg (66lbs
Block Diagram
ES – Single A1
Description
- One side of stereo single system
- Up to 1000 people
- Number of bass cabinets and SUB LEVEL setup
- depends on the style of music
Products :
Count : Product
- 1 ES1.0
- 1 ES1.5
- 1 EPAK2500 / R
Accessories:
Count : Accessory Title
- 1 Cable MH60
- 1 Cable LF40
ES – Single A2
Description
- One side of stereo single system
- Up to 1000 people
- Number of bass cabinets and SUB LEVEL setup
- depends on the style of music
Products:
Count : Product
- 1 ES1.0
- 2 ES1.5
- 1 EPAK2500 / R
Accessories:
Count : Accessory Title
- 1 Cable MH60
- 1 Cable LF15
- 1 Cable LF40
ES – Single A3
Description
- Right side of stereo single system
- Up to 1000 people
- Number of bass cabinets and SUB LEVEL setup
- depends on the style of music
Products:
Count : Product
- 1 ES1.0
3 ES1.5
1 EPAK2500 / R
Accessories:
Count : Accessory Title
- 1 Cable MH60
- 2 Cable LF15
- 1 Cable LF40
ES – Single B1
Description
- Right side of stereo single system
- Up to 1000 people
- Number of bass cabinets and SUB LEVEL setup
- depends on the style of music
Products:
Count : Product
- 1 ES1.0
- 2 ES1.5
- 1 ES1.8
- 1 EPAK2500 / R
Accessories:
Count : Accessory Title
- 1 Cable MH60
- 2 Cable LF15
- 1 Cable LF40
ES – Single B2
Description
-
One side of stereo single system
-
Up to 1000 people
-
Number of bass cabinets and SUB LEVEL setup
- depends on the style of music
-
Products:
Count Product -
1 ES1.0
-
1 ES1.8
-
1 ES2.6
-
1 EPAK2500 / R
Accessories:
Count : Accessory Title
- 1 Cable MH60
- 1 Cable LF15
- 1 Cable LF40
ES – Single C
Description
- One side of stereo single system
- Up to 1000 people
- Number of bass cabinets and SUB LEVEL setup
- depends on the style of music
Products:
Count : Product
- 1 ES1.0
- 1 ES2.5
- 1 EPAK2500 / R
Accessories:
Count : Accessory Title
- 1 Cable MH60
- 1 Cable LF40
- 1 KV2-H
- (1 ES1.0 Vertical Bracket)
ES – Single D
Description
- One side of stereo single system
- Up to 1000 people
- Number of bass cabinets and SUB LEVEL setup
- depends on the style of music
Products:
Count : Product
- 1 ES1.0
- 2 ES2.6
- 1 EPAK2500 / R
Accessories:
Count : Accessory Title
- 1 Cable MH60
- 1 Cable LF40
- 1 Cable LF15
ES – Single E
Description
- One side of stereo single system
- Up to 1000 people
- Number of bass cabinets and SUB LEVEL setup
- depends on the style of music
Products:
Count : Product
- 1 ES1.0
2 ES1.8
1 EPAK2500 / R
Accessories:
Count : Accessory Title
- 1 Cable MH60
- 1 Cable LF15
- 1 Cable LF40
ES – Double A
Description
- Right side of stereo double system
- Up to 2000 people
- Number of bass cabinets and SUB LEVEL setup
- depends on the style of music
Products:
Count : Product
- 2 ES1.0
- 1 ES2.5
- 2 ES1.8
- 2 EPAK2500 / R
Accessories:
Count : Accessory Title
- 2 Cable MH60
- 1 Cable LF15
- 2 Cable LF40
ES – Double B
Description
- Right side of stereo double system
- Up to 2000 people
- Number of bass cabinets and SUB LEVEL setup
- depends on the style of music
Products:
Count : Product
- 2 ES1.0
- 4 ES1.8
- 2 EPAK2500 / R
Accessories:
Count : Accessory Title
- 2 Cable MH120
- 2 Cable LF40
- 2 Cable LF15
- 1 FLY BAR – 0002
ES – Double C
Description
- Right side of stereo double system
- Up to 2000 people
- Number of bass cabinets and SUB LEVEL setup
- depends on the style of music
Products:
Count : Product
- 2 ES1.0
- 2 ES2.5
- 2 EPAK2500 / R
Accessories:
Count : Accessory Title
- 2 Cable MH120
- 2 Cable LF40
- 1 FLY BAR – 0002
ES – Double D
Description
- Right side of stereo double system
- Up to 2000 people
- Number of bass cabinets and SUB LEVEL setup
- depends on the style of music
Products:
Count : Product
- 2 ES1.0
- 4 ES2.6
- 1 EPAK2500 / R
Accessories:
Count : Accessory Title
- 2 Cable MH120
- 2 Cable LF40
- 2 Cable LF15
- 1 FLY BAR – 0002
Accessories
ES Mid/Hi speaker cable MH15, AP6 connectors – 1,5 m
part name: MH15
part number : KVV 987 147
- 1,5 m (5ft), Mid/Hi Module hook-up
ES Mid/Hi speaker cable MH60, AP6 connectors – 6 m
part name: MH60
part number: KVV 987 125
- 6 m (20ft), Mid/Hi Module hook-up
ES Mid/Hi speaker cable MH120, AP6 connectors – 12 m
part name: MH120
part number: KVV 987 126
- 12 m (40ft), Mid/Hi Module hook-up
ES Mid/Hi speaker cable MH180, AP6 connectors – 18 m
part name: MH180
part number: KVV 987 127
- 18 m (60ft), Mid/Hi Module hook-up
ES Bass speaker cable LF15, AP4 connectors – 1,5 m
part name: LF15
part number: KVV 987 121
- 1,5 m (5ft)
- for ES Bass Module daisy-chaining
ES Bass speaker cable LF40, AP4 connectors – 4 m
part name: LF40
part number: KVV 987 122
- 4 m (13ft)
- for ES Bass Module hook-up
ES Bass speaker cable LF100, AP4 connectors – 10 m
part name: LF100
part number: KVV 987 123
- 10 m (33ft)
- for ES Bass Module hook-up
Amphenol AP6 cable-mount female connector
part name: AP-6-11
part number: KVV 987 050
Amphenol AP6 cable-mount male connector
part name: AP-6-12
part number: KVV 987 051
Amphenol AP4 cable-mount female connector
part name: AP-4-11
part number: KVV 987 048
Amphenol AP4 cable-mount male connector
part name: AP-4-12
part number: KVV 987 049
ES Cable kit
part name: CABLE-KIT
part number: KVV 987 047
The ES Cable Pack consist of four high-quality Amphenol AP cable assemblies
designed for use with ES Series.
- 2 pcs LF15
- 1pc LF40
- 1pc MH60
ES Bass speaker cable LF200, AP4 connectors – 20 m
part name: LF200
part number: KVV 987 124
- 20m (66ft)
- for ES Bass Module hook-up
Warranty
Your EPAK2500R is covered against defects in material and workmanship.
Refer to your supplier for more details.
Service
In the unlikely event that your EPAK2500R develops a problem, it must be
returned to an authorized distributor, service centre or shipped directly to
our factory. Because of the complexity of the design and the risk of
electrical shock, all repairs must be attempted only by qualified technical
personnel.
If the unit needs to be shipped back to the factory, it must be sent in its
original carton. If improperly packed, the unit may be damaged.
To obtain service, contact your nearest KV2 Audio Service Centre, Distributor
or Dealer.
The Future of Sound.
Made Perfectly Clear.
KV2 Audio International
Nádražní 936, 399 01 Milevsko
Czech Republic
Tel.: +420 383 809 320
Email: info@kv2audio.com
www.kv2audio.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>