Quick setup

  • Insert fluorescent tube into the light fixture and twist to lock in place
  • Attach a hanging clip to each end.
  • Connect power cable
  • Hang 45cm to 60cm above the grow canopy
  • Set timer to switch the UV light on for about 2 hours in the middle of each ‘lights on’ cycle
  • Use only for the last 3 weeks of flowering

Safety

Please read this manual thoroughly before assembling and installing the MIGRO grow lights system Please retain this manual for reference for the lifetime for the product

To minimise risk please switch the power off while installing and adjusting the MIGRO system. If the mains plug needs to be changed to suit your power socket only a qualified person should carry out this work, in accordance with your local codes.

The MIGRO system will operate on a supply voltage ranging from 100V to 277V AC and from 50 to 60Hz frequency. Any other supply voltage will damage the lighting system.
The grow light and the power cable are IP54 rated and cannot be used in a wet area. The mains power plug is not IP rated for a wet area and should be located in a dry area outside of the grow room. If the cable insulation or glands are damaged switch off the system immediately and return to us for repair.

Do not cover the grow light and restrict the airflow across the fixture under any circumstances. This will result in heat build up which may damage the grow light and/or cause a fire.

Do not put the grow light down on any surface when the light is on. The UV radiation and radiated heat may damage the surface.
The UVB radiation from the light fixture can damage eyes and skin. Switch off the UVB grow light when in the grow room. Any object within 90cm or 3ft of the fixture in the direction of the radiation may be damaged over time (bleaching them for example).

Damage during shipping

There is a chance of damage to the bulb during shipping but can you please double check some things before contacting us:

  1. Test the power is on in the socket you are using.
  2. Check the power lead is pushed firmly into the light fixture.
  3. With the power off please twist the fluorescent tube a little until it is about 90 Degrees to the angle it was pushed in.
  4. Power on and test.
  5. If it does not power up in a few seconds please power off, twist the tube a little and try again

If it still does not start up contact us and we will send a replacement tube as it was likely damaged during shipping

The fluorescent tube will ’rattle’
The fluorescent tube will make a rattling noise. This is due to a small amount of metals in the tube.
These metals evaporate when powered up and emit the UV photons

The light output may be wavey on initial startup
The mercury ball may lodge in the filament at the end of the tube. If there is waviness please wait for the fixture to warm up after a few minutes and tilt the fixture from side to side to move the metals around the tube for even illumination.

Installation instructions

Insert the T8 Fluorescent tube into the Light fixture and twist until secure Attach the hanging clips to the light fixture, one on each end
Installation instructions

Hang the fixture

Position the light fixture between 45cm and 60cm (18 – 24 inches) above the plant canopy

When to use it

  • The aim is to stimulate the production of essential oils and increase potency. This is best achieved in the last 3 weeks of flowering.
  • Set the control timer to switch the UVB light on for 1.5hours (45cm hanging height) to 2 hours (60cm hanging height) per light cycle
  • If there is no noticeable plant damage (browning on leaf tips) then increase in 0.5 hour increments and check for damage again.
  • Keep increasing to maximise the dosage until some browning or bleaching on the tips is observed than reduce the time by 0.5 hours

Hanging height and UVB intensity
Hanging height and UVB intensity

General specifications

The MIGRO UVB 310 is an 18W Fluorescent tube, hanging Light fixture with 2M (6ft) power cable

  • Fluorescent tube: T8 UVB LAMP, 20W, 589.8mm, 230V, Wavelength 310- 320nm, G13 base.
  • Light Fixture: AC100-277V 50/60HZ 0.6MM aluminium body, UV reflective aluminium reflector, electronic ballast, PF0.5CE/UL EMC, bodysize: 6156040mm reflector width: 60mm, 2M 2*0.75 cores cable, hanging: 2 x stainless hooks
  • Hanging height: 60cm (2ft”)
  • Light dimensions: 62cm long x 6cm wide and 5cm high (24″ x 2.5″ x 2″)
  • Power consumed: 22 watts
  • Voltage / Current: 110V / 1.1 Amp; 220V / 0.5 Amp
  • Spectrum peak: UVB 310 nm
  • Lifetime: 5,000 hours
  • Warranty: 1 year
  • Hanging weight: 300g (11 Oz)
  • Shipping contents include:
    • Light fixtures: 1 x 60cm or 2ft T8 UVB fluorescent tube
    • Driver: 1 x T8 60cm or 2ft Fluorescent light fixture with UV reflective aluminium reflector
    • Cables: 2m cable
    • Plug: UK, US, Euro, Swiss or AUS plug options

Contact for technical support
Email: info@migrolight.com
Website: www.migrolight.com
Youtube: MIGRO channel – optimise your grow light setup
Telephone: 00 353 (0)1 8245716

Company logo

Documents / Resources

| MIGROLIGHT UVB 310 Fixture and Fluorescent Tube [pdf] Instruction Manual
UVB 310 Fixture and Fluorescent Tube, UVB 310, Fixture and Fluorescent Tube, Fluorescent Tube, Tube
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals