GHOST AXP1 5 Button Premium Remote Transmitter Owner’s Manual
- June 13, 2024
- Ghost
Table of Contents
GHOST AXP1 5 Button Premium Remote Transmitter
Product Information
The Premium Remote is a 5-button remote transmitter used to control gates. It features an LED light for visual feedback and two remotes, Remote A (Training) and Remote B (Learning), for programming and controlling the gate. The remote has buttons for activating Gate 1 or Gate 2 and a Learn button for programming additional remotes. The transmitting remote (Remote A) is used to program the receiving remote (Remote B) by placing them in close proximity and following the programming sequence.
Product Usage Instructions
Programming Remote to Gate Controller
- Press and hold the LEARN XMTR button on the gate system controller.
- While holding the LEARN XMTR button, press and hold either Button 1 or Button 2 on Remote A for 2 seconds.
- Release the Button on Remote A when the gate controller alarm beeps or the gate begins moving.
- Press and release the programmed Button on Remote A to test the transmitter. The LED on the transmitter should turn on when the button is depressed to indicate transmission. Each press of the button will cycle the gate: OPEN-STOP-CLOSE-STOP OPEN. The LED will flash rapidly while transmitting, and the maximum transmitting time is approximately 20 seconds.
Adding an Additional Remote Transmitter
- Press and hold the LEARN button on Remote B (Learning) for at least 3 seconds until the LED stays on.
- While holding the LEARN button on Remote B, press and hold either Button 1 or Button 2 on Remote A (Teaching Remote).
- Release the Button on Remote A when the LED on both remotes stays on.
- Press and release the Button on Remote B to indicate that it is now programmed to operate the same gate as Remote A.
Cloning/Copying Button 1’s ID to Button 2
- Press and hold the LEARN button on the remote for at least 3 seconds until the LED stays on.
- Release the LEARN button to put the remote in Learning Mode.
- Press and release Button 1 on the remote. The LED should start flashing twice per second, indicating that Button 1’s ID is being sent.
- Press and release Button 2 on the remote. The LED should turn off, indicating that Button 1’s ID is accepted by Button 2. Both buttons should now work the same gate.
Cloning/Copying Button 2’s ID to Button 1
- Press and hold the LEARN button on the remote for at least 3 seconds until the LED stays on.
- Release the LEARN button to put the remote in Learning Mode.
- Press and release Button 2 on the remote. The LED should start flashing twice per second, indicating that Button 2’s ID is being sent.
- Press and release Button 1 on the remote. The LED should turn off, indicating that Button 2’s ID is accepted by Button 1. Both buttons should now work the same gate.
INSTRUCTIONS
5-BUTTON PREMIUM REMOTE TRANSMITTER PROGRAMMING AND REMOTE TRANSMITTER
All GHOST CONTROLS® remote transmitters must be programmed before they will
operate the Gate Opener System so that the safety and security of your system
is maintained.
OVERVIEW
NOTE:
REMOTES A & B MUST BE TOUCHING AND ORIENTED AS SHOWN TO PROGRAM REMOTE B FROM
REMOTE A
PROGRAMMING REMOTE TO GATE CONTROLLER
PARTYMODE® (HOLD OPEN) FUNCTION
Enabling PartyMode® through a remote transmitter sends a command/message to
the gate controller to turn PartyMode® function On or Off. The gate opener
system
will remain in PartyMode® until the gate controller receives a signal to be
disabled or the power button on the Control Box is cycled to the off position.
Once PartyMode® has been disabled, all functions such as AUTOCLOSE will return
to their previous operation.
GATE SYSTEM CONTROLLER DIAGNOSTIC MODE
Diagnostic Mode function sends a command/message to the gate controller to
activate diagnostics indicators (LEDs and/or alarm codes) on the gate
controller. Refer to the gate opener manual for specific details about the
indicators. To conserve the battery power, the main controller indicators
(LEDs and alarm) are turned off when gate is idled for more than 60 seconds
(except for UL-325 requirement for entrapment protection). Enabling Diagnostic
Mode will turn these indicators on for 5 minutes without the need to operate
the gate.
IMPORTANT
Pressing the Test button on the remote transmitter indicates the status of the
gate system controller battery. It does not indicate the status of the CR2032
battery inside of the remote itself.
GENERATING A NEW TRANSMITTING KEY CODE
CAUTION
- Please READ and PROCEED with CAUTION
- Each GHOST CONTROLS® remote transmitter has a unique key code sequence. Once a new key sequence is generated, the previous key code is lost.
- The new key code will need to be programmed or “learned” into the gate opener to control the gate.
FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference
- This device must accept any interference received, including interference that may cause undesired operation.
WARNING
Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
NOTE This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced technician for help.
WARNING
- This product contains a Button or Coin Cell Battery.
- A swallowed Button or Coin Cell Battery can cause internal chemical burns in as little as two hours and lead to death.Dispose of used batteries immediately.
- Keep new and used batteries away from childern.
- If you think batteries might have been swallowed or placed inside any part of the body,seek immediate medical attention.
WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov
Documents / Resources
|
GHOST AXP1 5 Button Premium Remote
Transmitter
[pdf] Owner's Manual
AXP1 5 Button Premium Remote Transmitter, AXP1, 5 Button Premium Remote
Transmitter, Premium Remote Transmitter, Remote Transmitter
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>