GHOST CONTROLS Standard Photo Eyes User Guide

June 5, 2024
GHOST CONTROLS

STANDARD PHOTO EYES

AXPS INSTRUCTIONS (NONMONITORED)

**UNMONITORED PHOTO EYES INSTALLATION OVERVIEW FOR SINGLE AND DUAL

GATES**

Driveway
Inside of Property
DUAL GATE DIAGRAM 2

PREPARING CONTROL BOX FOR PHOTO-EYE WIRING

■ MAKE SURE THE POWER IS TURNED OFF AND BATTERY IS DISCONNECTED TO THE CONTROL BOX BEFORE WIRING
■ On the bottom of the control box, there is a built-in knockout for wires. Drill a hole and knock it out and install a strain relief.
This is where your wires will feed up into the control box and connect to the control board.

PAIR 1 PHOTO-EYE INSTALLATION AND WIRING

PAIR 1 Photo Eye RECEIVER needs to be installed on the Control Box side of the gate opener. The TRANSMITTER needs to be installed facing and across from the RECEIVER. You will also need to dig a trench for the two (2) TRANSMITTER wires to go across and connect the TRANSMITTER TO THE RECEIVER. The RECEIVER wires will then connect to the control box. Use 20-22 AWG gauge stranded wire. (see CLOSING -REVERSE CONNECTION DIAGRAM next page).

CONNECTIONS FOR CLOSING-REVERSE (PAIR 1)

Transmitter

| Receiver|

Ghost Control Board

---|---|---
1| 1| LOCK +
2| 2| COM
N/A| 4| COM
N/A| 5| CLS_RVRS

(see CLOSING -REVERSE CONNECTION DIAGRAM on next page).

CLOSING -REVERSE CONNECTION DIAGRAM – PAIR 1

PAIR 2 PHOTO-EYE INSTALLATION AND WIRING

PAIR 2 Photo Eye RECEIVER needs to be installed on the Control Box side of the gate opener. The TRANSMITTER needs to be installed facing and across from the RECEIVER. You will also need to dig a trench for the two (2) TRANSMITTER wires to go across and connect the TRANSMITTER TO THE RECEIVER. The RECEIVER wires will then connect to the control box. Use 20-22 AWG gauge stranded wire. (see OPENING -REVERSE CONNECTION DIAGRAM next page).

CONNECTIONS FOR OPENING-REVERSE (PAIR 2)

Transmitter

| Receiver|

Ghost Control Board

---|---|---
1| 1| LOCK +
2| 2| COM
N/A| 4| COM
N/A| 5| OPN_RVRS

DUAL GATES: PAIR 3 PHOTO EYE INSTALLATION AND WIRING
PAIR 3 Photo Eye RECEIVER needs to be installed on the Control Box side of the gate opener. The TRANSMITTER needs to be installed facing and across from the RECEIVER. You will also need to dig a trench for the two (2) TRANSMITTER wires to go across and connect the TRANSMITTER TO THE RECEIVER. The RECEIVER wires will then connect to the control box. Use 20-22 AWG gauge stranded wire. (see OPENING -REVERSE CONNECTION DIAGRAM).

DUAL ONLY: CONNECTIONS FOR OPENING-REVERSE (PAIR 3)

Transmitter Receiver Ghost Control Board
1 1 LOCK +
2 2 COM
N/A 4 COM
N/A 5 OPN_RVRS

(see OPENING -REVERSE CONNECTION DIAGRAM).

OPENING -REVERSE CONNECTION DIAGRAM – PAIR 2

OPENING -REVERSE CONNECTION DIAGRAM – PAIR 3

SETTING UP THE DIP SWITCHES.

ALL UNITS COME FROM THE FACTORY PAIRED AS PAIR 1. When using more than 1 pair of photo eyes you will need to reset switches for Pair 2 and 3 during installation with the below instructions.

PAIR 1 PHOTO EYES (FACTORY SET)

GHOST CONTROLS Standard Photo Eyes - FACTORY SET

PAIR 2 PHOTO EYES
GHOST CONTROLS Standard Photo Eyes - PHOTO EYES 1

PAIRING YOUR 2ND PHOTO EYES:
STEP 1: Remove + power on main control board for 2nd pair of photo eyes.
STEP 2: Place the dip switches in the positions shown in diagrams A1 and B1 above.
STEP 3: Restore + power on pair 2. Both unit’s displays will show the number 2. Leave on for 10 seconds.
STEP 4: Remove + power and reposition the dips as shown in diagrams A2 and B2.
STEP 5: Restore + power to pair 2. You are now ready to test beams to ensure a proper response from the gate opener.

PAIR 3 PHOTO EYES

GHOST CONTROLS Standard Photo Eyes - PHOTO EYES 1

PAIRING YOUR 3RD PHOTO EYES:

STEP 1 : Remove + power on main control board for 3rd pair of photo eyes.
STEP 2 : Place the dip switches in the positions shown in diagrams C1 and D1 above.
STEP 3 : Restore + power on pair 3. Both unit’s displays will show the number 2. Leave on for 10 seconds.
STEP 4 : Remove + power and reposition the dips as shown in diagrams C2 and D2.
STEP 5 : Restore + power to pair 3. You are now ready to test beams to ensure a proper response from the gate opener.

WARNING
Extreme caution must be exercised when the automatic gate opener system is in operation, regardless of which safety systems are installed and in use.

MOUNTING PRECAUTIONS

Never mount your detector where plants, direct sunlight, and headlights could obstruct the beam between the transmitter and receiver. ALSO, MAKE SURE THE SURFACE IS EVEN AND NOT UNSTABLE. See diagrams below

GHOST CONTROLS Standard Photo Eyes - transmitter

MOUNTING YOUR PHOTO-EYES ON A POLE (FOLLOW DIAGRAMS BELOW)

■ Loosen the screw on the underside of Photo-Eye and back out approximately 1/4 inch.
■ Gently lift the cover from the bottom side and angle slightly outwards (as shown).
■ Slide the cover upwards and then forwards to remove the cover from the housing.
■ USE METAL PIPE TO PREVENT MOVEMENT

GHOST CONTROLS Standard Photo Eyes - PIPE

MOUNTING YOUR PHOTO-EYES ON A WALL (FOLLOW DIAGRAMS NEXT PAGE)

■ Loosen the screw on the underside of Photo-Eye and back out approximately 1/4 inch.
■ Gently lift the cover from the bottom side and angle slightly outwards (as shown).
■ Slide the cover upwards and then forwards to remove the cover from the housing.

GHOST CONTROLS Standard Photo Eyes - rubber

Note: for the wall-mounting method, the two rubber knockouts will need to be removed from the housing.

MOUNTING DISTANCE AND ADJUSTMENTS

■ The unit will turn off the display and the buzzer after 1 minute of power- up. The unit is still fully functional only the display is turned off.

GHOST CONTROLS Standard Photo Eyes - Beam Alignment

ADJUSTING RESPONSE TIME ON THE RECEIVER

■ When set all the way clockwise means a faster response time (50 msec).
■ When set all the way counterclockwise means a slower response time (240 msec).
■ Factory setting response time is set approximately in the middle.

WARNING:
This product can expose you to chemicals including lead, which is known to the State of California to cause cancer.
For more information, go to www.P65Warnings.ca.gov

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GHOST CONTROLS User Manuals

Related Manuals