GHOST CONTROLS Standard Photo Eyes User Guide
- June 5, 2024
- GHOST CONTROLS
Table of Contents
- AXPS INSTRUCTIONS (NONMONITORED)
- **UNMONITORED PHOTO EYES INSTALLATION OVERVIEW FOR SINGLE AND DUAL
- PREPARING CONTROL BOX FOR PHOTO-EYE WIRING
- PAIR 1 PHOTO-EYE INSTALLATION AND WIRING
- CLOSING -REVERSE CONNECTION DIAGRAM – PAIR 1
- PAIR 2 PHOTO-EYE INSTALLATION AND WIRING
- OPENING -REVERSE CONNECTION DIAGRAM – PAIR 2
- OPENING -REVERSE CONNECTION DIAGRAM – PAIR 3
- SETTING UP THE DIP SWITCHES.
- MOUNTING PRECAUTIONS
- MOUNTING YOUR PHOTO-EYES ON A POLE (FOLLOW DIAGRAMS BELOW)
- MOUNTING YOUR PHOTO-EYES ON A WALL (FOLLOW DIAGRAMS NEXT PAGE)
- MOUNTING DISTANCE AND ADJUSTMENTS
- ADJUSTING RESPONSE TIME ON THE RECEIVER
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
STANDARD PHOTO EYES
AXPS INSTRUCTIONS (NONMONITORED)
**UNMONITORED PHOTO EYES INSTALLATION OVERVIEW FOR SINGLE AND DUAL
GATES**
Driveway
Inside of Property
DUAL GATE DIAGRAM 2
PREPARING CONTROL BOX FOR PHOTO-EYE WIRING
■ MAKE SURE THE POWER IS TURNED OFF AND BATTERY IS DISCONNECTED TO THE CONTROL
BOX BEFORE WIRING
■ On the bottom of the control box, there is a built-in knockout for wires.
Drill a hole and knock it out and install a strain relief.
This is where your wires will feed up into the control box and connect to the
control board.
PAIR 1 PHOTO-EYE INSTALLATION AND WIRING
PAIR 1 Photo Eye RECEIVER needs to be installed on the Control Box side of the gate opener. The TRANSMITTER needs to be installed facing and across from the RECEIVER. You will also need to dig a trench for the two (2) TRANSMITTER wires to go across and connect the TRANSMITTER TO THE RECEIVER. The RECEIVER wires will then connect to the control box. Use 20-22 AWG gauge stranded wire. (see CLOSING -REVERSE CONNECTION DIAGRAM next page).
CONNECTIONS FOR CLOSING-REVERSE (PAIR 1)
Transmitter
| Receiver|
Ghost Control Board
---|---|---
1| 1| LOCK +
2| 2| COM
N/A| 4| COM
N/A| 5| CLS_RVRS
(see CLOSING -REVERSE CONNECTION DIAGRAM on next page).
CLOSING -REVERSE CONNECTION DIAGRAM – PAIR 1
PAIR 2 PHOTO-EYE INSTALLATION AND WIRING
PAIR 2 Photo Eye RECEIVER needs to be installed on the Control Box side of the gate opener. The TRANSMITTER needs to be installed facing and across from the RECEIVER. You will also need to dig a trench for the two (2) TRANSMITTER wires to go across and connect the TRANSMITTER TO THE RECEIVER. The RECEIVER wires will then connect to the control box. Use 20-22 AWG gauge stranded wire. (see OPENING -REVERSE CONNECTION DIAGRAM next page).
CONNECTIONS FOR OPENING-REVERSE (PAIR 2)
Transmitter
| Receiver|
Ghost Control Board
---|---|---
1| 1| LOCK +
2| 2| COM
N/A| 4| COM
N/A| 5| OPN_RVRS
DUAL GATES: PAIR 3 PHOTO EYE INSTALLATION AND WIRING
PAIR 3 Photo Eye RECEIVER needs to be installed on the Control Box side of the
gate opener. The TRANSMITTER needs to be installed facing and across from the
RECEIVER. You will also need to dig a trench for the two (2) TRANSMITTER wires
to go across and connect the TRANSMITTER TO THE RECEIVER. The RECEIVER wires
will then connect to the control box. Use 20-22 AWG gauge stranded wire. (see
OPENING -REVERSE CONNECTION DIAGRAM).
DUAL ONLY: CONNECTIONS FOR OPENING-REVERSE (PAIR 3)
Transmitter | Receiver | Ghost Control Board |
---|---|---|
1 | 1 | LOCK + |
2 | 2 | COM |
N/A | 4 | COM |
N/A | 5 | OPN_RVRS |
(see OPENING -REVERSE CONNECTION DIAGRAM).
OPENING -REVERSE CONNECTION DIAGRAM – PAIR 2
OPENING -REVERSE CONNECTION DIAGRAM – PAIR 3
SETTING UP THE DIP SWITCHES.
ALL UNITS COME FROM THE FACTORY PAIRED AS PAIR 1. When using more than 1 pair of photo eyes you will need to reset switches for Pair 2 and 3 during installation with the below instructions.
PAIR 1 PHOTO EYES (FACTORY SET)
PAIR 2 PHOTO EYES
PAIRING YOUR 2ND PHOTO EYES:
STEP 1: Remove + power on main control board for 2nd pair of photo eyes.
STEP 2: Place the dip switches in the positions shown in diagrams A1 and B1
above.
STEP 3: Restore + power on pair 2. Both unit’s displays will show the number
2. Leave on for 10 seconds.
STEP 4: Remove + power and reposition the dips as shown in diagrams A2 and B2.
STEP 5: Restore + power to pair 2. You are now ready to test beams to ensure a
proper response from the gate opener.
PAIR 3 PHOTO EYES
PAIRING YOUR 3RD PHOTO EYES:
STEP 1 : Remove + power on main control board for 3rd pair of photo eyes.
STEP 2 : Place the dip switches in the positions shown in diagrams C1 and
D1 above.
STEP 3 : Restore + power on pair 3. Both unit’s displays will show the
number 2. Leave on for 10 seconds.
STEP 4 : Remove + power and reposition the dips as shown in diagrams C2
and D2.
STEP 5 : Restore + power to pair 3. You are now ready to test beams to
ensure a proper response from the gate opener.
WARNING
Extreme caution must be exercised when the automatic gate opener system is in
operation, regardless of which safety systems are installed and in use.
MOUNTING PRECAUTIONS
Never mount your detector where plants, direct sunlight, and headlights could obstruct the beam between the transmitter and receiver. ALSO, MAKE SURE THE SURFACE IS EVEN AND NOT UNSTABLE. See diagrams below
MOUNTING YOUR PHOTO-EYES ON A POLE (FOLLOW DIAGRAMS BELOW)
■ Loosen the screw on the underside of Photo-Eye and back out approximately
1/4 inch.
■ Gently lift the cover from the bottom side and angle slightly outwards (as
shown).
■ Slide the cover upwards and then forwards to remove the cover from the
housing.
■ USE METAL PIPE TO PREVENT MOVEMENT
MOUNTING YOUR PHOTO-EYES ON A WALL (FOLLOW DIAGRAMS NEXT PAGE)
■ Loosen the screw on the underside of Photo-Eye and back out approximately
1/4 inch.
■ Gently lift the cover from the bottom side and angle slightly outwards (as
shown).
■ Slide the cover upwards and then forwards to remove the cover from the
housing.
Note: for the wall-mounting method, the two rubber knockouts will need to be removed from the housing.
MOUNTING DISTANCE AND ADJUSTMENTS
■ The unit will turn off the display and the buzzer after 1 minute of power- up. The unit is still fully functional only the display is turned off.
ADJUSTING RESPONSE TIME ON THE RECEIVER
■ When set all the way clockwise means a faster response time (50 msec).
■ When set all the way counterclockwise means a slower response time (240
msec).
■ Factory setting response time is set approximately in the middle.
WARNING:
This product can expose you to chemicals including lead, which is known to the
State of California to cause cancer.
For more information, go to
www.P65Warnings.ca.gov