DSC PC5401 Data Interface Module Instruction Manual
- June 13, 2024
- DSC
Table of Contents
Installation Instructions
The PC5401 Data Interface Module can be used to quickly and easily communicate with PowerSeries™ panels through a standard RS-232 serial connection. (See the PC5401 Developer’s Guide for more information on communicating with the PC5401 module) at www.dsc.com/support/installation manuals.
Specifications
Module Current Draw: 35 mA
Terminal Connections
KEYBUS – The 4-wire KEYBUS connection is used by the panel to communicate
with the module. Connect the RED, BLK, YEL and GRN terminals to the KEYBUS
terminals on a PowerSeries™ panel.
DB9 – Requires a “straight-through” RS-232 cable. Only the RX, TX and GND
connections are used. Note: cable should not exceed 50 ft at 9600 BAUD
(consult RS-232 Signaling Standard for more information)
To Connect Module to a Control Panel
This module can be installed in any of the following enclosures: PC4003C,
PC5003C, HS-CAB1000, HS-CAB3000, HS-CAB4000.
- Connect module to the KEYBUS (with the panel powered down).
- Select desired BAUD using JP1-3 (default is 9600 BAUD, see Table 1).
- Connect an RS-232 cable to the application.
- Power up the system.
Notes:
- The PC5401 is designed to be installed by SERVICE PERSONS only.
- These instructions shall be used in conjunction with the applicable Installation Instructions of the used PowerSeries™ alarm controller.
Table 1: BAUD Selection
BAUD selection can only be changed by cycling power to the module.
BAUD | JMP3 | JMP2 | JMP1 |
---|---|---|---|
4800 | ON | ON | OFF |
19200 | ON | OFF | ON |
57600 | ON | OFF | OFF |
9600 | OFF | OFF | OFF |
Table 2: Indicator LEDs
LED | Description | Normal Operation | Notes |
---|---|---|---|
KEY | KEYBUS Link Active | GREEN Solid | Indicates the module is correctly |
connected to the KEYBUS
PWR| Module Status| RED Flashing (2 seconds)| LED Flashes every 2 seconds
when module is operating normally. A solid RED means that the module is not
operating properly. If the
LED is unlit, the module is not powered correctly, check cabling.
Limited Warranty
Digital Security Controls warrants that for a period of twelve months from the
date of purchase, the product shall be free of defects in material and
workmanship under normal use and that in fulfillment of any breach of such
warranty, Digital Security Controls shall, at its option, repair or replace
the defective equipment upon return of the equipment to its repair depot. This
warranty applies only to defects in parts and workmanship and not to damage
incurred in shipping or handling, or damage due to causes beyond control of
Digital Security Controls such as lightning, excessive voltage, mechanical
shock, water damage, or damage arising out of abuse, alteration or improper
application of the equipment. The foregoing warranty shall apply only to the
original buyer, and is and shall be in lieu of any and all other warranties,
whether express or implied and of all other obligations or liabilities on the
part of Digital Security Controls . This warranty contains the entire
warranty. Digital Security Controls neither assumes responsibility, nor
authorizes any other person purporting to act on its behalf to modify or to
change this warranty, nor to assume for it any other warranty or liability
concerning this product. In no event shall Digital Security Controls be liable
for any direct, indirect or consequential damages, loss of anticipated
profits, loss of time or any other losses incurred by the buyer in connection
with the purchase, installation or operation or failure of this product.
WARNING: DSC recommends that the entire system be completely tested on a
regular basis. However, despite frequent testing, and due to but not limited
to, criminal tampering or electrical disruption, it is possible for this
product to fail to perform as expected.
FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved by Digital
Security Controls Ltd. could void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not installed
and used properly, in strict accordance with the manufacturer’s instructions,
may cause interference to radio and television reception. It has been type
tested and found to comply with the limits for Class B device in accordance
with the specifications in Subpart “B” of Part 15 of FCC Rules, which are
designed to provide reasonable protection against such interference in any
residential installation. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
interference to television or radio reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Re-orient the receiving antenna
- Relocate the alarm control with respect to the receiver
- Move the alarm control away from the receiver
- Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the FCC useful: “How to Identify and Resolve Radio/Television Interference Problems”. This booklet is available from the U.S. Government Printing Office, Washington D.C. 20402, Stock # 004-000-00345-4.
© 2004 Digital Security Controls
Toronto, Canada • www.dsc.com
Technical Support: 1-800-387-3630