AMI MARINE X150 Bridge Navigational Watch Alarm System User Manual
- June 9, 2024
- AMI MARINE
Table of Contents
AMI MARINE X150 Bridge Navigational Watch Alarm System
BNWAS150 – Bridge Navigational Watch Alarm System
Document Revision| Date| Modification Number (where applicable) Brief Record
of Change and Reason for Change
---|---|---
Iss02| 13.09.17| Original Issue
|
NOTE:
All alterations must be verified by re-authorisation and approval of the complete document.
AMI MARINE LTD
Unit 9, Crosshouse Centre
Crosshouse Road
Southampton
SO14 5GZ
United Kingdom
Tel No: +44 (0) 23 8048 0450
Email: technical@amimarine.com
Web: www.amimarine.com
**IMPORTANT WARNINGS
**
DANGER! RISK OF ELECTRICAL SHOCK!
Disconnect from the power before removing protective covers.
DO NOT remove the covers while the unit is switched on.
24/12 Volt DC electrical power on external units.
NOTICE
Compass safe distance is 1 metre.
NOTICE
No user serviceable parts inside, servicing only by properly qualified and
certified technical staff.
NOTICE
This manual is for informational use only, and may be changed without notice. This manual should not be construed as a commitment of AMI Marine Ltd. Under no circumstances does AMI Marine Ltd assume any responsibility or liability for any errors or inaccuracies that may appear in this document. The equipment should only be used for the purposes intended by the manufacturer; any deviation from this will void the warranty of the product.
BNWAS 150 System Overview
The BNWAS 150 system is designed for use on a vessel’s navigation bridge. The
remote alarm sounders cover key locations such as the officer cabins, mess
area and ship’s office. Reset devices can be used on the bridge wings.
The display control and monitoring equipment is to be installed in protected
areas inside the bridge.
Dormant Time
This function is adjustable between 3-12 minutes in 1 minute increments only whilst in SETUP mode.
Remote Resets
BNWAS 150 has a reset mechanism which can be activated by a combination of reset pushbuttons and PIR motion detection sensors.
Fail Alerts
BNWAS 150 has alert messages for Tamper, Power and Battery. Tamper alert is also audible by means of an on-board buzzer within the display control unit.
Emergency Call and Cabin Call
BNWAS 150 has an Officer call configurable in up to 5 officer cabins within the menu.
Power supply
BNWAS 150 is powered by two separate 24 Volt supplies (main and backup) which will automatically switch to the backup supply in the event of a main supply failure. This will raise an alarm.
Inputs from Valid Reset Devices & System Alarms
BNWAS 150 provides additional Digital Inputs to accept signals from other devices and transfer alarms. An external equipment in alarm will send a digital input to the BNWAS and the source will be shown on LCD display. These might include RADAR or ECDIS.
External valid reset inputs must be approved by the appropriate approval body before being used. AMI Marine (UK) Ltd will assist with recommendations wherever possible from previous experience but will not accept responsibility if not accepted.
BNWAS 150 comprises
Hardware consisting of – Control display panel, interface unit, physical and sensory reset devices, alarm sounders and beacons. The BNWAS 150 Software Navigation Menu where the Master can configure and control the operational mode and parameters of the system.
Overall Layout
There are three areas within the vessel were the system and peripheral units are fitted:-
Wheel house / Bridge
Accommodation Areas Remote Locations Wheel house / Bridge Equipment – Control display, Stage 1 Alarm sounders, Alarm Beacon, Directional PIR’s, and push button reset switches. Push buttons can be mounted on the Bridge wing, and are IP rated accordingly.
Accommodation Decks
Equipment – Stage 2 Alarms are located in the accommodation area. The system is configurable through the navigation menu, for five separate accommodation rooms, labelled: Cabin 1, Cabin 2, Cabin 3, Cabin 4, Cabin 5 – (Captain, Officer 1, 2, 3 and 4) The alarm sounders or sounder beacons can be used.
Remote Locations
Equipment – Stage 3 Alarms are located in remote locations which could include Officer’s mess, Office locations and Engine Control Room. They can be alarm sounders or sounder beacons.
BNWAS 150 Controls and Functions
X150-D Display and Control
The BNWAS X150-D Display Control Panel is the user interface and display for the BNWAS150 The display control panel is to be mounted at a suitable location within the ship bridge preferably at a location where the watch officer is expected to be stationed during normal on watch operations
The Key switch has 2 positions which change the function of the tactile
buttons;
1. RUN – Normal operation position where the system is monitoring all sensor
inputs.
2. SETUP – To set the ‘Operational Mode’ and to adjust the timing parameters.
EMERGENCY CALL / UP
CABIN CALL / DOWN
ALARM RESET / SELECT
Automatic Dimming of the LCD Display
A light detection sensor automatically dims the display at low light levels to
prevent light pollution during night time operation.
X150-RI Illuminated Reset Pushbutton and X150-RE Illuminated Reset Pushbutton with Buzzer
The RI-150 reset pushbutton unit can be used to reset the BNWAS system’s timer before or during the 1st stage alarm. The RE-150 unit performs the same function but also has an audible alarm making it ideal for use on the bridge wings.
X150-SD Alarm Sounder and 150-SB Sounder Beacon
The X150-SD alarm sounders are used for the 2nd or 3rd stage alarms and have adjustable volume between 85 and 105dB. The X150-SB performs the same function but also has a highly visible LED indication.
Software Setup and Operation
Switching On The BNWAS 150
SETUP Menu
The SETUP mode allows the user to access the SETUP MENU and customise the
timing parameters within the BNWAS 150 menus. To enter the SETUP mode insert
the key and turn clockwise to SETUP.
Mode Selection
In the SETUP menu you can step sequentially through the three different modes
of operation by pressing the SELECT button. The three different modes are:-
ON
The system functions as per the set timing parameters. Alarms as per IMO
standard MSC128(75).
OFF
System operation inhibited. The Emergency Call function is still operational
AUTO
When this mode is selected the system runs as per “ON” mode only if Autopilot
signal is active; otherwise operation is inhibited. This function should only
be used with class approval.
STAGE ALARM 3 Timing Selection
Press the SELECT button until you arrive at the Stage Alarm 3 timing option.
Stage 2 to Stage 3 Delay Time
The Stage 2 to Stage 3 delay is defined in seconds. This is the time from the Stage 2 alarm becoming active to the Stage 3 alarms becoming activate, assuming Stage 2 is not acknowledged in the meantime.
The Stage 2 to Stage 3 delay is configured using the UP and DOWN buttons. A time between 90 seconds and 180 seconds in 10 second steps can be entered. When the desired timing is displayed press the SELECT button.
DORMANT Period Timing Selection
Press the SELECT button until you arrive at the dormant period timing option.
Dormant Period Time
The dormant period is defined in minutes. This period is the time taken
from initial start-up, or operator reset, to the Visual Alert Stage being
initiated. The dormant period is configured using the UP and DOWN buttons to
toggle between digits 3 and 12. When the desired period is displayed press the
SELECT button.
BNWAS150 Startup
On first power up a message from the system designers will appear on the
display.
The software version and date will then be displayed followed by CPU 1 and CPU
2 running a self-test, a short beep will be heard on completion.
After a few seconds the operating screen will be displayed
Entering Setup
i nsert the MODE key and turn clockwise – the status indication will
change from to .
Press SELECT button – mode will change from to The BNWAS is now set to OFF.
Pressing the SELECT button again, will cause the mode to change from OFF to
Auto OFF If the Autopilot is connected the system will automatically turn ON
and OFF as the autopilot is engaged and disengaged.
Mode Selection
Pressing the SELECT button again, will change Period to
Pressing the SELECT button again will change to . If the key is turned to RUN and removed the system is now in the OFF mode
Pressing the SELECT button again will change to . If the key is turned to RUN and removed the system is now in the Automatic mode. The display will change to if the Autopilot is connected and the Autopilot is engaged.
Stage 2 to Stage 3 Delay
Pressing the SELECT button again will change to . By using the and buttons the stage 3 alarm time can be changed, from 90 seconds (1:30) up to 180 seconds (3:00 minutes) in 10 second steps.
Initial Dormant Period
Pressing the SELECT button again will change to .By using the UP and DOWN buttons the dormant period time can be changed from 3 minutes to 12 minutes, in 1 minute steps.
Operational Sequence
When the BNWAS countdown reaches the message will appear. The display and the remote reset buttons will now flash. To reset the system press the RESET button or press a remote reset button.
15 Seconds after Stage Alarm is displayed will be displayed and the Stage 1 alarm on the display unit will audible alarm along with any local sounder. To reset the system press the RESET button or press a remote reset button.
15 Seconds after Stage Alarm 1 is displayed will be displayed and Stage 2 and the selected cabin sounders will also begin to sound. To reset the system press the RESET button or press a remote reset button.
1:30 to 3:00 minutes after stage 2, depending on the stage 3 delay setting, will be shown and all sounders will sound in all installed locations. To reset the system press the RESET button on the display. NB: Pressing the remote resets, or motion detected by the PIR will not reset the system once stage 3 alarm has been reached.
, In the event of an emergency press and hold the EMERGENCY CALL button until the alarm sounds. All stage 1 and the selected cabin sounders will become active. To reset the system press the RESET button on the display. NB: Pressing the remote resets or motion detected by the PIR will not reset the EMERGENCY CALL.
Selecting Duty Cabins and Using Cabin Call
Selecting Duty Cabins for Stage 2 Alarm
The Selecting and De-selecting Cabins function can only be accessed when the system is in MODE.
Press and hold the SELECT button until appears. With the SELECT button held press UP to move between the cabins and press DOWN to select or de-select a cabin. When selected the cabin‘s number will be remain displayed.
Example: Removing – which is selected in the screen to the left. Press and
hold the SELECT button and will appear at cabin number 1
While still holding the SELECT button, press UP and the cursor will move to
the next cabin location.
Repeat this past cabin , still holding the SELECT button and pressing UP again
While still holding the SELECT button, press UP once more so that is shown
on the display.
Continue to hold down the SELECT button. Once at cabin number , press DOWN –
will now be shown instead of . Cabin 4 is now de-selected and will not be
alerted at stage 2 or when Cabin Call is pressed.
Using Cabin Call Function
If the CABIN CALL button is pressed the message appears and the cabins selected at the bottom of the screen will have their sounders activated. In this case cabins 1 and 3 will be called. Press the RESET button to clear the CABIN CALL.
External Reset
(if external equipment connected)
message will be shown when the RADAR is in use by an operator and the BNWAS
timer will reset. (This will only be shown if the RADAR in use connection is
made)
message will be shown when the ECDIS is in use by an operator and the BNWAS
timer will reset.
(This will only be shown if the ECDIS in use connection is made)
message will be shown when the equipment connected to Auxiliary 1 is in use by
an operator and the BNWAS timer will reset.
(This will only be shown if the Auxiliary 1 connection is made)
message will be shown when the equipment connected to Auxiliary 2 is in use by
an operator and the BNWAS timer will reset.
(This will only be shown if the Auxiliary 2 connection is made)
Unacknowledged Alarms (if external equipment connected)
This will be displayed if an unacknowledged alarm is received from the
Radar. Pressing the RESET button will display any other active alarms but will
not reset the alarm.
(This will only be shown if the RADAR alarm is connected)
This will be displayed if an unacknowledged alarm is received from the ECDIS.
Pressing the RESET button will display any other active alarms but will not
reset the alarm. (This will only be shown if the ECDIS alarm is connected)
This will be displayed if an unacknowledged alarm is received from the
Autopilot. Pressing the RESET button will display any other active alarms but
will not reset the alarm. (This will only be shown if the Autopilot alarm is
connected)
This will be displayed if an
unacknowledged alarm is received from the Echo Sounder. Pressing the RESET
button will display any other active alarms but will not reset the alarm.
(This will only be shown if the Echo Sounder alarm is connected)
This will be displayed if any unacknowledged alarms, other than those listed above, are received by the BNWAS. Pressing the RESET button will display any other active alarms but will not reset the alarm.
NOTE!! For all of the above unacknowledged alarms, pressing the RESET button will have not reset any alarm until the equipment generating the alarm has been acknowledged.
System Faults
Power Error
If the main power fails the standby power will be used to power the system. This is indicated by the MAIN POWER FAIL being displayed on the LCD screen until the main power is restored to the system.
will be shown if the main power input fails. Press the RESET button to clear message. If message does not clear check main power input.
If the standby power fails, while main power remains on, STANDBY POWER FAIL will be indicated on the LCD display until the standby power is restored
will be shown if the standby power fails. Press the RESET button to clear message. If message does not clear check standby power input.
Tamper Error
If the interface to any peripheral device is disconnected, “Tamper” will be
displayed on the LCD screen. This will continue to be displayed until the
cause of the tamper is removed.
If the message appears, the PIRs or one of the reset
switches may have been tampered with or have become faulty. Check the PIR’s
and reset switches for damage. Press the RESET button to clear the message
once any fault has been rectified. If remains displayed there is a further
problem with another PIR or reset switch.
Maintenance guide
The BNWAS 150 system requires periodic (annually) confirmation that all sensors are active, and conduct a full system integrity check.
Any damaged/inactive peripherals MUST be replaced by a suitable spare part by an approved engineer.
All cabling and interfaces should be re-checked to confirm system integrity and any damaged cables must be replaced/re-wired if required by an approved engineer.
Any changes made above must be tested to confirm system operation.
Any warranty void d marks/visible tampering must be logged to prevent future disruption and system damage.
© This Manual and the information contained therein is the property of AMI Marine Ltd. It must not be reproduced or otherwise disclosed without prior consent in writing from AMI Marine Ltd
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>