Abridged installation instructions
T.Flow® Hygro+
T.Flow® Nano
This guide does not replace the complete installation instructions. For
further information, please refer to the complete installation instructions.
Any equipment failure due to non-observance of manufacturer instructions and
failure to respect applicable standards and regulations or lack of maintenance
shall render the warranty null and void.
HANDLING
HEATER INSTALLATION
The water heater must be installed on a smooth, horizontal surface (+/- 1°).
If the surface is not level, the water heater must be made level using its
legs.
If this precaution is not taken, condensation evacuation issues may occur.
If the heater is WALL-MOUNTED the installation must respect the requirements
of French standard NF DTU 60.1. Depending on the type of wall, it may be
necessary to install the heater on a tripod.
The water heater must be attached to the wall using screws and wall plugs
suited to the wall and the weight of the unit (in accordance with EN
60-335-1).
If the heater is installed ON A TRIPOD, it must always be fixed to the wall
(at least by the upper attachment bracket).
Indicative weight of filled water heater
- B100 T. Flow Nano: 176 kg
- B100 FAN-T. Flow Nano: 178 kg
AERAULIC CONNECTIONS
Ducts must be securely connected to the water heater, using the clamp collars supplied as accessories. However, ensure that it is possible to disconnect the air ducts for future purposes.
Outlet ducting
The heat pump captures the heat in the extracted air so the exhaust air
discharged by the system is cold. To avoid any risk of condensation inside or
outside the duct, the ducting must be insulated to a minimum of 25 mm.
In all events, the air outlet must be sufficiently dimensioned to avoid
extensive pressure losses. An air outlet that generates excessive pressure
losses may cause the system to malfunction. It is preferable to use ALDES
roof-mounted or wall-mounted outlets.
HYDRAULIC CONNECTION
Dielectric connectors
The cold water inlet and hot water outlet must be fitted with dielectric
connectors (supplied with the heater unit) even if the tank connections use
cross-linked polyethylene pipe. If these connectors are not fitted, our
warranty will be null and void.
Never apply a torque greater than 25 N.m.
Hot water outlet
We recommend the installation of one or more temperature limiters (not
supplied).
Cold water inlet
The heater must be equipped with a new safety switch (not supplied) configured
to 7 bar and compliant with standard EN 1487.
The system must include a pressure reducer (not supplied) if the mains water
supply pressure is higher than 0.45 MPa. The pressure reducer must be
installed on the mains supply inlet.
Condensate discharge
Install a drain siphon and fill it with water (a membrane siphon can also be
used, which does not need to be filled with water). Check the pipe routing
once connected to avoid any pinching.
If these instructions are not respected, our warranty will be null and void.
ELECTRICAL CONNECTION
- The thermodynamic water heater must have a constant supply to guarantee the production of domestic hot water and the operation of the titanium impressed current anode.
- The thermodynamic water heater must not be electrically connected until it has been filled with water and the pipes connected.
Never supply the heating element directly with power.
By default, the interface language is French. To change the interface to
English:
– Hold down the “MODE” and “OK” keys simultaneously for a very brief moment to
enter the advanced menu;
– Press “+” to show the “LANG. <> LANGUAGE menu ”and“ OK ”to validate the
selection;
– Select the English language (En) with the “+” or “-” key and confirm with
the “OK” key.
All menus and interface settings are now displayed in English.
GERMANY
Technische Unterstützung notwendig?
– Sie sind Profi-Kunde:+49 (0) 6721-9178 112 •
service@exhausto.de • +49 (0) 6721-9178 112
– Sie sind Privatkunde: Bitte wenden Sie sich an Ihren örtlichen Installateur
oder einen Lüftungsprofi Ihrer Wahl.
OTHERS COUNTRIES
Need after sales technical support?
Visit our website for more information: https://www.aldes-
international.com/fr/contact/
Aldes-TFlowHygroNano-Guide-35033219D – 012022 – RCS 956 506 828 – Aldes – Imprimé en France/ Printed in France
ALDES Service Consommateur
20 boulevard Joliot Curie