Abridged installation instructions

T.Flow® Hygro+
T.Flow® Nano

This guide does not replace the complete installation instructions. For further information, please refer to the complete installation instructions.
Any equipment failure due to non-observance of manufacturer instructions and failure to respect applicable standards and regulations or lack of maintenance shall render the warranty null and void.

HANDLING

aldes T.Flow Hygro Thermodynamic Water Heater On Ambient Air - Fig
1

HEATER INSTALLATION

The water heater must be installed on a smooth, horizontal surface (+/- 1°).
If the surface is not level, the water heater must be made level using its legs.
If this precaution is not taken, condensation evacuation issues may occur.

aldes T.Flow Hygro Thermodynamic Water Heater On Ambient Air - Fig
3

If the heater is WALL-MOUNTED the installation must respect the requirements of French standard NF DTU 60.1. Depending on the type of wall, it may be necessary to install the heater on a tripod.
The water heater must be attached to the wall using screws and wall plugs suited to the wall and the weight of the unit (in accordance with EN 60-335-1).
If the heater is installed ON A TRIPOD, it must always be fixed to the wall (at least by the upper attachment bracket).

Indicative weight of filled water heater

  • B100 T. Flow Nano: 176 kg
  • B100 FAN-T. Flow Nano: 178 kg

AERAULIC CONNECTIONS

aldes T.Flow Hygro Thermodynamic Water Heater On Ambient Air - Fig
4

Ducts must be securely connected to the water heater, using the clamp collars supplied as accessories. However, ensure that it is possible to disconnect the air ducts for future purposes.

Outlet ducting
The heat pump captures the heat in the extracted air so the exhaust air discharged by the system is cold. To avoid any risk of condensation inside or outside the duct, the ducting must be insulated to a minimum of 25 mm.
In all events, the air outlet must be sufficiently dimensioned to avoid extensive pressure losses. An air outlet that generates excessive pressure losses may cause the system to malfunction. It is preferable to use ALDES roof-mounted or wall-mounted outlets.

HYDRAULIC CONNECTION

Dielectric connectors
The cold water inlet and hot water outlet must be fitted with dielectric connectors (supplied with the heater unit) even if the tank connections use cross-linked polyethylene pipe. If these connectors are not fitted, our warranty will be null and void.
Never apply a torque greater than 25 N.m.

Hot water outlet
We recommend the installation of one or more temperature limiters (not supplied).
Cold water inlet
The heater must be equipped with a new safety switch (not supplied) configured to 7 bar and compliant with standard EN 1487.
The system must include a pressure reducer (not supplied) if the mains water supply pressure is higher than 0.45 MPa. The pressure reducer must be installed on the mains supply inlet.

Condensate discharge
Install a drain siphon and fill it with water (a membrane siphon can also be used, which does not need to be filled with water). Check the pipe routing once connected to avoid any pinching.
If these instructions are not respected, our warranty will be null and void.

aldes T.Flow Hygro Thermodynamic Water Heater On Ambient Air - Fig
5

ELECTRICAL CONNECTION

  • The thermodynamic water heater must have a constant supply to guarantee the production of domestic hot water and the operation of the titanium impressed current anode.
  • The thermodynamic water heater must not be electrically connected until it has been filled with water and the pipes connected.
    Never supply the heating element directly with power.

aldes T.Flow Hygro Thermodynamic Water Heater On Ambient Air - Fig
6

By default, the interface language is French. To change the interface to English:
– Hold down the “MODE” and “OK” keys simultaneously for a very brief moment to enter the advanced menu;
– Press “+” to show the “LANG. <> LANGUAGE menu ”and“ OK ”to validate the selection;
– Select the English language (En) with the “+” or “-” key and confirm with the “OK” key.
All menus and interface settings are now displayed in English.

aldes logo

GERMANY
Technische Unterstützung notwendig?
– Sie sind Profi-Kunde:+49 (0) 6721-9178 112 • service@exhausto.de • +49 (0) 6721-9178 112
– Sie sind Privatkunde: Bitte wenden Sie sich an Ihren örtlichen Installateur oder einen Lüftungsprofi Ihrer Wahl.

OTHERS COUNTRIES
Need after sales technical support?

Visit our website for more information: https://www.aldes- international.com/fr/contact/

www.aldes.com

Aldes-TFlowHygroNano-Guide-35033219D – 012022 – RCS 956 506 828 – Aldes – Imprimé en France/ Printed in France

ALDES Service Consommateur
20 boulevard Joliot Curie
69694 Vénissieux Cedexaldes T.Flow Hygro Thermodynamic Water Heater On
Ambient Air - Symbol 6

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals