legrand G6017TX 6000 Series Combination Internal External Elbow Fitting User Guide
- June 13, 2024
- Legrand
Table of Contents
- WIREMOLD®
- Steel Raceway
- Large Capacity, Two-Piece Steel Surface Raceway
- FEATURES & BENEFITS
- 6000 Series Raceway System Layout
- 6000 Raceway Wire Fill Capacity for Power
- 6000 Raceway Cable Fill Capacities for Data/Communications
- 6000 Series Raceway Ordering Information
- 4047 Series Cover Plates Ordering Information
- 4047 Series Configurable Cover Plates Number Logic
- 4000 Series Faceplates Ordering Information
- Communication Endplates Ordering Information
- V/G4050 & 5507 Series Faceplates Ordering Information
- NOTES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WIREMOLD®
Steel Raceway
Large Capacity, Two-Piece Steel Surface Raceway
6000® Series Raceway can be used divided for separate wiring circuits or multi-service applications. For large cabling installations, 6000 can be used undivided as headers and feeders or to bring wiring to a specified location. 6000 Series Raceway is ideal for all applications requiring a high cable capacity, dual service steel raceway. Commercial, institutional, and industrial applications all benefit from the 6000 Series rigid steel construction and durable Ivory ScuffCoat™ finish. 6000 Series Raceway is also ideal for municipalities that require either all steel construction or prohibit nonmetallic cable management systems.
6000® Series Raceway shown as a divided system with Activate inserts and
power device with a 4050 device bracket.
FEATURES & BENEFITS
- Steel raceway. Provides superior strength for any dry interior location installation.
- Extra large cross sectional area. Provides space for large wiring requirements or installations that use large diameter cable for power and/or data/communications.
- Dividable raceway base. Snap-in divider creates two-compartment raceway. For bringing large amounts of power and data/communications cable to one location.
- Complete line of fittings. Provides complete wiring solution and allows for interconnection between raceway systems.
- Gray baked enamel and Ivory ScuffCoat finish. Enamel finish assures durability; can be easily overpainted. Durable Ivory Scuffcoat finish makes a scratch resistant surface.
- Installs as a feeder or header raceway. Ideal for overhead, open spaces and underfloor applications.
- Accommodates large size devices. Large size raceway accepts single- and dual-gang devices up to 100 amps and circuit breakers up to three pole.
- Pre-cut covers for standard outlet center locations. For mounting devices on various centers without cutting the covers which reduces number of field cuts for labor savings.
- Base and cover cutters. Manually operated cutters are lightweight and portable. Cutters offer labor savings for any size job and maintain a factory clean and square cut.
- Communication connectivity options. Accepts industry standard and proprietary devices from a wide range of manufacturers to provide a seamless and aesthetically pleasing interface for voice, data, audio, and video applications at the point of use.
- ADA compliant. Raceway and fittings can be installed in conformance with ADA requirements.
- UL Listed and CSA Certified. Raceway UL file E4376 Guide RJBT, CSA file LR350. Fittings UL file 41751 Guide RJPR, CSA file 350 and 48952.
Download this product’s PEP ecopasport® environmental product declaration at www.legrand.us/resources-and-downloads. This declaration conforms with ISO 14025 and 14040 and is in alignment with EN 15804.
4047 Series Faceplates accommodate a wide range of power and
communications applications.
ED530R18 – Updated April 2017 – For latest specs visitwww.legrand.us/wiremold
6000 Series Raceway System Layout
NOTE: Illustration is for showing single service product application only.
6000 Raceway Wire Fill Capacity for Power
WIRE SIZE THHN/THWN
| O.D.|
NUMBER OF CONDUCTORS (40% FILL)
---|---|---
WITHOUT DEVICES|
WITH DUPLEX RECT. DEVICES
1.59 in.² (1025mm² )
inches| (mm)| UNDIV.| DIVIDED| UNDIV.|
DIVIDED
14 AWG
| 0.111| (2.8)| 659| 296| 528|
231
12 AWG
| 0.130| (3.3)| 481| 216| 385| 168
10 AWG| 0.164| (4.2)| 303| 136| 243|
106
8 AWG
| 0.216| (5.5)| 174| 78| 140| 61
6 AWG| 0.254| (6.5)| 126| 56| 101|
44
4 AWG
| 0.324| (8.2)| 77| 34| 0| 0
3 AWG| 0.352| (8.9)| 65| 29| 0|
0
2 AWG
| 0.384| (9.8)| 55| 24| 0| 0
1 AWG| 0.446| (11.3)| 40| 18| 0|
0
1/0 AWG
| 0.486| (12.3)| 34| 15| 0| 0
2/0 AWG| 0.532| (13.5)| 28| 12| 0|
0
WIRE SIZE THHN/THWN
| O.D.| NUMBER OF CONDUCTORS (40% FILL)
---|---|---
WITH SURGE/ GFCI DEVICES
2.30 in. ² (1485mm ² )|
LARGE SINGLE RECEPTACLES
3.00 in.² (1935mm²)
inches
| (mm)| UNDIV.| DIVIDED| UNDIV.| DIVIDED
14 AWG| 0.111| (2.8)| 470| 202| 412|
173
12 AWG
| 0.130| (3.3)| 342| 147| 300| 126
10 AWG| 0.164| (4.2)| 216| 92| 189|
79
8 AWG
| 0.216| (5.5)| 124| 53| 109| 45
6 AWG| 0.254| (6.5)| 89| 38| 78|
33
4 AWG
| 0.324| (8.2)| 0| 0| 0| 0
3 AWG| 0.352| (8.9)| 0| 0| 0|
0
2 AWG
| 0.384| (9.8)| 0| 0| 0| 0
1 AWG| 0.446| (11.3)| 0| 0| 0|
0
1/0 AWG
| 0.486| (12.3)| 0| 0| 0| 0
2/0 AWG| 0.532| (13.5)| 0| 0| 0|
0
NOTE: For additional information, refer to the Technical Section of ED1560 (Product Guide).
6000 Raceway Cable Fill Capacities for Data/Communications
CABLE TYPE
| CATEGORY / DESIGNATION| O.D.| DIVIDED 40% FILL| UNDIVIDED
40% FILL
---|---|---|---|---
Inches|
(mm)
UNSHIELDED TWISTED PAIR| 4-PAIR, 24 AWG Cat 3|
0.190
| (4.8)| 101|
225
4-PAIR, 24 AWG Cat 5e|
0.210
| (5.3)| 83|
184
4-PAIR, 24 AWG Cat 6|
0.250
| (6.3)| 58|
130
4-PAIR, 24 AWG Cat 6a*|
0.354
| (9.0)| 29|
65
25-PAIR, 24 AWG Cat 6|
0.410
| (10.4)| 21|
48
TELEPHONE| 2-pair, 24 AWG|
0.140
| (3.6)| 187|
415
3-pair, 24 AWG|
0.150
| (3.8)| 163|
362
4-pair, 24 AWG|
0.190
| (4.8)| 101|
225
25-pair, 24 AWG|
0.410
| (10.4)| 21|
48
COAXIAL| RG58/U|
0.195
| (5.0)| 96|
214
RG59/U|
0.242
| (6.1)| 62|
139
RG62/U|
0.242
| (6.1)| 62|
139
RG6/U|
0.270
| (6.9)| 50|
111
TWINAXIAL| 100 Ohm|
0.330
| (8.4)| 33|
74
SHIELDED TWISTED PAIR| TYPE 1|
0.390
| (9.9)| 24|
53
TYPE 2|
0.465
| (11.8)| 16|
37
TYPE 3|
0.245
| (6.2)| 61|
135
FIBER| Mini ZipCord|
0.079 x 0.157
| (2 x 4)| 232|
516
ZipCord|
0.118 x 0.236
| (3 x 6)| 103|
230
Round 4 Strand Fiber|
0.187
| (4.8)| 104|
233
Round 6 Strand Fiber|
0.256
| (6.5)| 55|
124
NOTE: Capacity range is calculated at 20% to 40% of raceway area as stated in a proposed revision to the Commercial Building Standard for Telecommunication Pathways & Spaces, TIA/EIA-569. Actual wire fill capacity may vary based on applications, cable types, and number, as well as type of fittings. (Fitting may cause additional variances to the fill capacity.)
* Category 6 augmented (6a) cable for 10 gigabit ethernet – max allowed cable diameter per addenda No. 11 ANSI TIA/EIA 568-B.2.
6000 Series Raceway Ordering Information
Catalog No./Item | Description/Specifications |
---|
V6000B-10
G6000B010| Base – .060″ (1.5mm) galvanized steel. Packed two 10′ (3m)
lengths per carton. Base has two 9/32″ diameter trade size KOs 1 1/4″ (32mm)
from each end and on centers of approximately 18″ (457mm) throughout.
V6000C
G6000C| Cover – 040″ (1.0mm) galvanized steel. Packed four 5′ (1.5m)
per carton.
G6000DA**
| Divider – .040″ (1.0mm) galvanized steel. One side painted buff primer
to provide identification of compartments. Packed four 5′ (1.5m) lengths per
carton.
660B
| Base Cutter – Portable base cutter. Steel constructed provides clean
and easy square cuts. Manual operation required.
660BDK| Replacement Blade Kit – Replacement blade and die set for
640B Cutter.
640C
| Cover Cutter – Portable cover cutter. Steel constructed provides clean
and easy square cuts. Manual operation required.
640CDK| Replacement Blade Kit – Replacement blade and die set for
640C Cutter.
IWE-S
GWE-S| Spray Paint – Used for touching up large areas. Contains 12 oz.
of paint.
NOTE: Can only be shipped via ground transportation.
IWE-P
GWE-P| Touch-Up Paint Pen – Used for touching up small areas. Contains
0.3 oz. of paint.
6001A
| Coupling – For joining lengths of 6000B.
G6000WC
| Wire Clip – For holding conductors in place. Use only with undivided
6000 Series Raceway.
G6001DA†
| Divider Clip – For holding G6000DA Divider in place to divide raceway
into 1/3, 1/2, or 2/3 compartments. 6000 Raceway divided into 1/3 compartments
will not accept devices.
G6001TX
| Converter Coupling – For converting 6011TX or 6017TX into a tee or
cross. For tee, one required; for cross, two required.
G6008A
| C-Hanger – For suspending 6000 or 4000 Raceway from structural ceiling.
Designed for use with 3/8″ (9.5mm) rod. Hangers should be installed no more
than 4′ (1.2m) apart along raceway run. Can be bolted back-to- back for dual
runs of 4000, 6000, or to a G3008C for combined runs with 3000 Raceway.
**V4000C075/G4000C075***
| Pre-Cut Cover 7.5″ (191mm) – For mounting devices on 12″ (305mm)
centers with 4047 Series Cover Plates.
V4000C135/G4000C135
| Pre-Cut Cover 13.5″ (345mm) – For mounting devices on 18″ (457mm)
centers with 4047 Series Cover Plates.
V4000C195/G4000C195
| Pre-Cut Cover 19.5″ (495mm) – For mounting devices on 24″ (610mm)
centers with 4047 Series Cover Plates.
V4000C315/G4000C315
| Pre-Cut Cover 31.5″ (800mm) – For mounting devices on 36″ (915mm)
centers with 4047 Series Cover Plates.
V6006
G6006| Connection Cover – Use where two sections of 4000 or 6000 Series
Raceway Cover, not squarely cut, come together.
V6010B
G6010B| Blank End Fitting – For closing open end of 6000 Series
Raceway.
V6011TX
G6011TX|
Combination Flat Elbow – For using as a flat elbow, tee, or cross, (one
6001TX required for tee; two for cross; not included).
V6012TX
G6012TX|
Internal or External 45° Elbow – For making internal or external 45° turns
in a run of 6000 Series Raceway. Can also be assembled as an inverted 45°
elbow.
V6014A
G6014A| Connector Fitting – Has 1 1/4″, 1 1/2″ and 2″ (32mm, 38mm and
51mm) trade size KOs in back and on each side.
V6017TX
G6017TX| Combination Internal/External 90° Elbow – For use as internal
or external elbow, straight-through fitting, tee, or cross (one G6001TX
required for tee or straight through fitting; two for cross; not included).
V6046KD
G6046KD| Circuit Breaker Housing – KOs in cover can be removed for
installation of three single-pole breakers. For use with the following
breakers rated 100A maximum.
MANUFACTURER
| SERIES
General Electric Westinghouse|
THQC, THHQC Quicklag, C, QCH
V6074
G6074| Take-Off Connector (6000 to 6000) – For 90° tee connection at
any point along a run of 6000.
V6074A
G6074A| Take-Off Connector (6000 to 4000) – For 90° tee connection at
any point along a run of 6000.
V6086
G6086| Panel Connector – For connecting 6000 with surface type panel
boxes. Accommodates maximum wire capacity of 6000 system. Separate C-flange
fits around raceway, covering uneven cuts to the box. Cut 4 3/4″ x 3 9/16″
(121mm x 90mm) hole in panel box.
V6007C-1
G6007C-1| Single-Gang Device Cover – For vertical mounting single-gang
devices on undivided raceway. Accepts commercially available wall plate (sold
separately).
V6007C-2
G6007C-2| Two-Gang Device Plate – For installing two-gang devices or
two vertically mounted single-gang devices on undivided raceway. Accepts
commercially available wall plate (sold separately).
* 4000C and 6000C are compatible with 4000B and 6000B Raceway.
** G6001DA Divider Clips are required to hold divider in place.
† G6001DA Divider Clips are required to hold divider in place.
4047 Series Cover Plates Ordering Information
Catalog No./Item | Description/Specifications |
---|
V4047AX
G4047AX | Two-Gang Overlapping Cover Single Round Opening – For straight
blade and locking single receptacles with face diameters of 1.38″ to 1.39″
(35mm to 36mm).
V4047BX
G4047BX | Two-Gang Overlapping Cover Duplex Receptacle – For 15A and 20A
duplex receptacles. Accepts 106 Communications Duplex Frame.
V4047BB
G4047BB | Two-Gang Overlapping Cover Two Duplex Receptacles – For 15A
and 20A duplex receptacles. Accepts 106 Communications Duplex Frame.
V4047BF
G4047BF | Two-Gang Overlapping Cover Duplex & Modular Furniture – For
15A and 20A duplex receptacles. Includes combination Modular Furniture and two
Keystone twistouts. Accepts modular furniture adapter.
V4047BM
G4047BM | Two-Gang Overlapping Cover Duplex & 2A Mini adapter – For 15A
and 20A duplex receptacles. Includes Mini adapter. Accepts Pass & Seymour®
Activate inserts & Wiremold CM2 Series Open System Communication Modules.
V4047BS
G4047BS | Two-Gang Overlapping Cover Duplex & Series II Mini Adapter –
For 15A and 20A duplex receptacles. Includes Mini adapter. Accepts one
Ortronics® Series II Communication Insert.
V4047BT
G4047BT | Two-Gang Overlapping Cover Duplex & TracJack Mini Adapter –
For 15A and 20A duplex receptacles. Includes Mini adapter. Accepts two
Ortronics® TracJack Communication Inserts.
V4047C-1
G4047C-1 | One-Gang Overlapping Device Plate – Use with commercially
available single-gang flush plate (sold separately).
V4047C-2
G4047C-2 | Two-Gang Overlapping Device Plate – Use with commercially
available two-gang flush plate (sold separately).
V4047JX
G4047JX | Two-Gang Overlapping Cover Single Round Opening – For straight
blade and single locking receptacles with face diameters or 1.56″ – 1.58″
(39mm – 40mm).
V4047RX
G4047RX | Two-Gang Overlapping Cover Rectangle Opening – For rectangular
GFCI, Surge and decorator style devices. Does not accept 5507 Series
Faceplates.
V4047RF
G4047RF | Two-Gang Overlapping Cover Rectangle Opening & Modular
Furniture – For rectangular GFCI, Surge and decorator style devices. Does
not accept 5507 Series Faceplates. Accepts modular furniture adapter and
keystone RJ45 jacks.
V4047WX
G4047WX | Two-Gang Overlapping Cover with One Duplex Receptacle
Installed – Includes one Pass & Seymour Duplex Receptacle with 12″ wire
leads installed on bracket.
V4047WF
G4047WF | Two-Gang Overlapping Cover with One Duplex Installed & Modular
Furniture Opening – Includes one Pass & Seymour® 20 A Duplex Receptacle with
12″ wire leads installed on bracket. Includes combination Modular Furniture
and 2 Keystone Twist Out. Accepts modular furniture adapter and keystone RJ45
jacks.
V4047WM
G4047WM | Two-Gang Overlapping Cover with One Duplex Installed & Activate
Mini adapter – Includes one Pass & Seymour® 20A Duplex Receptacle with 12″
wire leads installed on Bracket. Includes Mini adapter. Accepts Activate
inserts & Wiremold CM2 Series Open System Communication Modules.
V4047WS
G4047WS | Two-Gang Overlapping Cover with One Duplex Installed & Series II
Mini adapter – Includes one Pass & Seymour® 20A Duplex Receptacle with 12″
wire leads installed on Bracket. Includes Mini adapter. Accepts one Ortronics®
Series II Communications insert.
V4047WT
G4047WT | Two-Gang Overlapping Cover with One Duplex Installed & TracJack
Mini adapter – Includes one Pass & Seymour® 20A Duplex Receptacle with 12″
wire leads installed on Bracket. Includes Mini adapter. Accepts two Ortronics®
TracJack Communications inserts.
V4047-2BBBB
G4047-2BBBB | Four-Gang Overlapping Cover Four Duplex Openings – For 15A
and 20A duplex receptacles. Accepts 106 Communication Duplex Frame.
V4047-2BBFF
G4047-2BBFF | Four-Gang Overlapping Cover Two Duplex & Two Modular
Furniture Openings – For 15A and 20A duplex receptacles. Includes
combination Modular Furniture & four Keystone Twistouts. Accepts keystone RJ45
or modular furniture adapter.
V4047-2BBMM
G4047-2BBMM | Four-Gang Overlapping Cover Two Duplex & Two Activate Mini
Adapters – For 15A and 20A duplex receptacles. Includes Mini adapter.
Accepts Activate inserts & Wiremold CM2 Series Open System Communications
Modules.
V4047-2BBSS
G4047-2BBSS | Four-Gang Overlapping Cover Two Duplex & Two Series II Mini
Adapters – For 15A and 20A duplex receptacles. Includes Mini adapter.
Accepts two Ortronics® Series II Communication inserts.
V4047-2BBTT
G4047-2BBTT | Four-Gang Overlapping Cover Two Duplex & Two TracJack Mini
Adapters – For 15A and 20A duplex receptacles. Includes Mini adapter.
Accepts four Ortronics® TracJack Communications inserts.
V4047-2BBXX
G4047-2BBXX | Four-Gang Overlapping Cover with Two Duplex Openings – For
15A and 20A duplex receptacles.
Accepts 106 Communication Duplex Frame.
V4047-2RRXX
G4047-2RRXX | Four-Gang Overlapping Cover Two Rectangular Openings – For
rectangular, GFCI, Surge and decorator style devices. Does not accept 5507
Series Faceplates.
V4047-2WWFF
G4047-2WWFF | Four-Gang Overlapping Cover Two Duplex Installed & Two
Modular Furniture Openings – Includes two, Pass & Seymour® 20A Duplex
Receptacles with 12″ wire leads installed on Bracket. Includes combination
Modular Furniture & four keystone Twistouts. Accepts modular furniture adapter
or RJ45.
V4047-2WWMM
G4047-2WWMM | Four-Gang Overlapping Cover with Two Duplex Installed & Two
Activate Mini Adapters – Includes two Pass & Seymour® 20A Duplex Receptacle
with 12″ wire leads installed on Bracket. Includes Mini adapter. Accepts two
Activate inserts & Wiremold CM2 Series Open System Communication Modules.
V4047-2WWSS
G4047-2WWSS | Four-Gang Overlapping Cover with Two Duplex Installed & Two
Series II Mini Adapters – Includes two Pass & Seymour® 20A Duplex
Receptacles with 12″ wire leads installed on Bracket. Includes Mini adapter.
Accepts two Ortronics® Series II Communication inserts.
V4047-2WWTT
G4047-2WWTT | Four-Gang Overlapping Cover with Two Duplex Installed & Two
TracJack Mini Adapters – Includes two Pass & Seymour® 20A Duplex Receptacles
with 12″ wire leads installed on Bracket. Includes Mini adapter. Accepts four
Ortronics® TracJack Communications inserts.
V4047-2WWXX
G4047-2WWXX | Four-Gang Overlapping Cover with Two Duplex Receptacles
Installed – Includes two Pass & Seymour® 20A Duplex Receptacles with 12″
wire leads installed on Bracket.
V4047UX
G4047UX| Bump-Up Extron® MAAP Device Plate – Accepts four Extron®
Electronics MAAP single space modules.
V4047VX
G4047VX| Bump-Up Extron® AAP Device Plate – Accepts two Extron®
Electronics AAP single space modules.
NOTE: Faceplates can also be used with 6000 Series Raceway.
Add “C” prefix to denote Canadian version – UL Listed to U.S. and Canadian
Safety Standards.
4047 Series Configurable Cover Plates Number Logic
1. For “X”, Choose one of the following options:
V Ivory & UL Listed CV Ivory & cULus Listed (Canada only)
G Gray & UL Listed CG Gray & cULus Listed (Canada only)
2. Choose a Plate Configuration:
Two-Gang Plate:
Four-Gang Plate:
3. For “Y”, Choose any combination of configurations from the options listed below:
A. 1.41″ (35.8mm) Diameter, Single Round Receptacle
B. Duplex Receptacle Opening
F. Combination Modular Furniture & **2 Keystone Twist Out
H. Mouse Hole Twist Out & Grommet
J. 1.59″ (40mm) Diameter, Single Round Receptacle
M. Pass & Seymour Activate 2A Mini **adapter Opening with Adapter
R. Rectangular Receptacle
S. Ortronics Series II 2A Mini adapter Opening with Adapter
T. Ortronics TracJack 2A Mini Adapter Adapter Opening with Adapter
W. Pass & Seymour Light Almond 20 Amp **Receptacle pre-pigtailed with 12″
wire leads installed on Bracket
X. Blank
Z. 3 Keystone Twist Out**
4. Finished Part Number
4047 4047-2
NOTE: For additional colors or configurations, call 1-800-621-0049, option 2.
4000 Series Faceplates Ordering Information
Catalog No./Item | Description/Specifications |
---|
V4046H-2
G 4046H-2| Tap-Off Fitting – Has four concentric 1/2″ and 3/4″
trade size KOs.
V6007C-1
G 6007C-1| Single-Gang Device Cover – For vertical mounting
single-gang devices on undivided raceway. Accepts commercially available wall
plate (sold separately).
V6007C-2
G 6007C-2| Two-Gang Device Plate – For installing two-gang devices
or two vertically mounted single-gang devices on undivided raceway.
- Accepts commercially available wall plate (not furnished).
NOTE: Faceplates can also be used with 6000 Series Raceway.
Add “C” prefix to denote Canadian version – UL Listed to U.S. and Canadian
Safety Standards.
Communication Endplates Ordering Information
Catalog No./Item | Description/Specifications |
---|
**ARA-S2***
| Angled Raceway Adapter – For use with 4050 device brackets and
WallSource device mounting brackets. Angled exit provides additional mounting
depth required for A/V connections as well as ensuring the required bend
radius for UTP and fiber optic cabling. Holds two Ortronics® Series II
modules. Fits 5507 Series Faceplate opening.
**CM-ARA***
| Angled Raceway Adapter – For use with 4050 device brackets and
WallSource device mounting brackets. Angled exit provides additional mounting
depth required for A/V connections as well as ensuring the required bend
radius for UTP and fiber optic cabling. Holds two Wiremold CM2 Series Open
System modules or two Pass & Seymour® 2A inserts. Fits 5507 Series Faceplate
opening.
**CM-EPLA***
| End Plates – Includes two outlet identification labels with clear
covers and two matching screw covers. Required for mounting Pass & Seymour®
Activate and Wiremold CM2 Series Open System communication modules into 4050
Series device brackets.
**S2-EPL***
| End Plates – Includes two outlet identification labels with clear covers and two matching screw covers. Required for mounting Ortronics Series II modules into 4050 Series device brackets.
* Add “G” suffix to indicate gray finish.
V/G4050 & 5507 Series Faceplates Ordering Information
Catalog No./Item | Description/Specifications |
---|
V4050
G 4050| Device Mounting Bracket – High impact plastic mounting
bracket and trim plate which overlap raceway cover providing a seamless
transition. For use with 5507 Series Faceplates, Ortronics® TracJack &Series
II Modules, Pass & Seymour Activate Series Inserts, and Wiremold CM2 Series
Open System Communication Modules.
**5507AD***
| Modular Furniture Adapter – For mounting modular furniture adapters.
**5507B***
| Blank Faceplate – For covering unused compartments in the device
bracket.
**5507D***
| Duplex Faceplate – For covering duplex style devices. Accepts 106
Communication Duplex Frame.
**5507R***
| Rectangular Faceplate – For covering rectangular style devices.
**5507S***
| Rectangular Spacer – For mounting commercial device plates. Installs
between the device bracket and a device.
**5507SW***
| Switch Faceplate – For covering standard toggle switches.
**5507T1***
| Single Receptacle Faceplate – For covering single receptacles – 1.59″
(40.4mm) diameter.
**5507T2***
| Single Receptacle Faceplate – For covering single receptacles – 1.41″
(35.8mm) diameter.
**5507RJ***
| Dual RJ11/RJ45 Connector Faceplate – For mounting one or two RJ type
keystone connectors – has one opening and a KO for the other.
**5507FRJ***
| Flush Dual RJ11/RJ45 Faceplate – Same as 5507RJ except the connectors
are recessed to provide a flush installation.
5507AAP
| Extron® AAP Faceplate – Accepts two Extron® Electronics AAP single
space modules.
5507MAAP
| Extron® MAAP Faceplate – Accepts four Extron® Electronics MAAP single
space modules.
**5507-4TJ***
| Ortronics Faceplate – For mounting Ortronics® communication inserts.
Accepts four TracJack Devices.
**5507-6TJ***
| Ortronics Faceplate – For mounting Ortronics® communication inserts. Accepts six TracJack Devices.
NOTE: All faceplates are 4 1/4″ long x 1 11/16″ wide (108mm x 43mm).
* Add “G” suffix to indicate gray finish.
Not for use with 4047BF and 4047RF Device Covers.
NOTES
NOTE: All brand and product names referenced in this document are registered trademarks or trademarks of their respective holders.
NOTE: The paper used to print this document is an environmentally responsible paper with 10% post consumer waste, with FSC and SFI Chain of Custody certifications, Lacey Act complaint. 100% of the electricity used to manufacture Flo sheets is generated with Green-e certified renewable energy.
Electrical Wiring Systems
60 Woodlawn Street
West Hartford, CT 06110
Phone: 1.877.BY.LEGRAND (295-3472)
www.legrand.us
570 Applewood Crescent
Vaughan, Ontario L4K 4B4
Phone:905.738.9195
www.legrand.ca
ED530R18 – Updated April 2017 – For latest specs
visitwww.legrand.us/wiremold
© Copyright 2017 Legrand All Rights Reserved
References
- Legrand CA | Delivering and Managing Power, Light, and Data
- Legrand US | Delivering and Managing Power, Light, and Data
- Resources
- Wiremold Wire and Cable Management Products from Legrand
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>