legrand G6010B 6000 Series Blank End Fitting User Guide

June 13, 2024
Legrand

legrand G6010B 6000 Series Blank End Fitting

Product Information

The Steel Raceway is a large-capacity, two-piece steel surface raceway designed for dry interior location installations. It provides superior strength and extra large cross-sectional area to accommodate large wiring requirements or installations that use large-diameter cables for power and/or data/communications. The raceway features a dividable base that creates a two- compartment raceway for bringing large amounts of power and data/communications cable to one location. It also comes with a complete line of fittings for interconnection between raceway systems.

The Steel Raceway has a gray baked enamel and Ivory ScuffCoat finish, ensuring durability and scratch resistance. It can be easily overpainted for customization. The raceway can be installed as a feeder or header raceway, making it ideal for overhead, open spaces, and underfloor applications. It accommodates large-size devices, accepting single- and dual-gang devices up to 100 amps and circuit breakers up to three poles. The Steel Raceway is ADA- compliant and can be installed in conformance with ADA requirements. It is UL- listed and CSA Certified, meeting safety standards for raceways and fittings.

Product Usage Instructions

To install the Steel Raceway, follow these steps:

  1. Prepare the installation area by ensuring it is clean and free from obstructions.
  2. Measure and mark the desired location for the raceway.
  3. Using appropriate tools, cut the raceway base to the desired length.
  4. If needed, snap in the divider to create a two-compartment raceway.
  5. Insert the wiring or cable into the raceway compartments, organizing them as needed.
  6. If using devices or fittings, install them at the desired locations within the raceway.
  7. Cover the raceway with the pre-cut covers for standard outlet center locations, ensuring they fit securely.
  8. If necessary, use base and cover cutters to make clean and square cuts on the raceway.

For specific wiring requirements and fill capacities, refer to the provided tables in the user manual. Ensure that the raceway is not overloaded with wires or cables beyond the recommended limits for safety and optimal performance.

For any additional information or technical details, refer to the Technical Section of the ED1560 Product Guide.

Large Capacity, Two-Piece Steel Surface Raceway
6000® Series Raceway can be used divided for separate wiring circuits or multi-service applications. For large cabling installations, 6000 can be used undivided as headers and feeders or to bring wiring to a specified location. 6000 Series Raceway is ideal for all applications requiring a high cable capacity, dual-service steel raceway. Commercial, institutional, and industrial applications all benefit from the 6000 Series rigid steel construction and durable Ivory ScuffCoat™ finish. 6000 Series Raceway is also ideal for municipalities that require either all steel construction or prohibit nonmetallic cable management systems.

6000® Series Raceway is shown as a divided system with Activate inserts and a power device with a 4050 device bracket.

FEATURES & BENEFITS

  • Steel raceway. Provides superior strength for any dry interior location installation.
  • Extra large cross-sectional area. Provides space for large wiring requirements or installations that use large-diameter cables for power and/or data/communications.
  • Dividable raceway base. Snap-in divider creates a two-compartment raceway. For bringing large amounts of power and data/communications cable to one location.
  • Complete line of fittings. Provides complete wiring solution and allows for interconnection between raceway systems.
  • Gray baked enamel and Ivory ScuffCoat finish. The enamel finish assures durability; and can be easily overpainted. A durable Ivory Scuffcoat finish makes a scratch-resistant surface.
  • Installs as a feeder or header raceway. Ideal for overhead, open spaces, and underfloor applications.
  • Accommodates large-size devices. Large-size raceway accepts single- and dual-gang devices up to 100 amps and circuit breakers up to three poles.
  • Pre-cut covers for standard outlet center locations. For mounting devices on various centers without cutting the covers which reduces the number of field cuts for labor savings.
  • Base and cover cutters. Manually operated cutters are lightweight and portable. Cutters offer labor savings for any size job and maintain a factory clean and square cut.
  • Communication connectivity options. Accepts industry standard and proprietary devices from a wide range of manufacturers to provide a seamless and aesthetically pleasing interface for voice, data, audio, and video applications at the point of use.
  • ADA compliant. Raceway and fittings can be installed in conformance with ADA requirements.
  • UL Listed and CSA Certified. Raceway UL file E4376 Guide RJBT, CSA file LR350. Fittings UL file 41751 Guide RJPR, CSA file 350, and 48952.

Download this product’s PEP ecopasport® environmental product declaration at www.legrand.us/resources-and-downloads. This declaration conforms with ISO 14025 and 14040 and is in alignment with EN 15804.

Series Raceway System Layout

legrand-G6010B-6000-Series-Blank-End-Fitting-fig-
\(5\)

Raceway Wire Fill Capacity for Power

6000 Raceway Wire Fill Capacity for Power



WIRE SIZE THHN/THWN

| ****



inches

| ****


O.D.

(mm)

| NUMBER OF CONDUCTORS (40% FILL)


WITHOUT DEVICES

| WITH DUPLEX RECT. DEVICES 1.59 in. 2 (1025mm 2 )| WITH SURGE/ GFCI DEVICES 2.30 in. 2 (1485mm 2 )| LARGE SINGLE RECEPTACLES 3.00 in. 2 (1935mm 2 )
UNDIV.| DIVIDED| UNDIV.| DIVIDED| UNDIV.| DIVIDED| UNDIV.| DIVIDED
14 AWG| 0.111| (2.8)| 659| 296| 528| 231| 470| 202| 412| 173
12 AWG| 0.130| (3.3)| 481| 216| 385| 168| 342| 147| 300| 126
10 AWG| 0.164| (4.2)| 303| 136| 243| 106| 216| 92| 189| 79
8 AWG| 0.216| (5.5)| 174| 78| 140| 61| 124| 53| 109| 45
6 AWG| 0.254| (6.5)| 126| 56| 101| 44| 89| 38| 78| 33
4 AWG| 0.324| (8.2)| 77| 34| 0| 0| 0| 0| 0| 0
3 AWG| 0.352| (8.9)| 65| 29| 0| 0| 0| 0| 0| 0
2 AWG| 0.384| (9.8)| 55| 24| 0| 0| 0| 0| 0| 0
1 AWG| 0.446| (11.3)| 40| 18| 0| 0| 0| 0| 0| 0
1/0 AWG| 0.486| (12.3)| 34| 15| 0| 0| 0| 0| 0| 0
2/0 AWG| 0.532| (13.5)| 28| 12| 0| 0| 0| 0| 0| 0

NOTE: For additional information, refer to the Technical Section of ED1560 (Product Guide).

Raceway Cable Fill Capacities for Data/Communications

6000 Raceway Cable Fill Capacities for Data/Communications

CABLE TYPE| ****

CATEGORY / DESIGNATION

| O.D.

Inches (mm)

| DIVIDED 40% FILL| UNDIVIDED 40% FILL
UNSHIELDED| 4-pair, 24 AWG Cat 3| 0.190                    (4.8)| 101| 225
TWISTED PAIR| 4-pair, 24 AWG Cat 5e| 0.210                    (5.3)| 83| 184
 | 4-pair, 24 AWG Cat 6| 0.250                    (6.3)| 58| 130
 | 4-pair, 24 AWG Cat 6a*| 0.354                    (9.0)| 29| 65
 | 25-pair, 24 AWG Cat 6| 0.410                  (10.4)| 21| 48
TELEPHONE| 2-pair, 24 AWG| 0.140                    (3.6)| 187| 415
 | 3-pair, 24 AWG| 0.150                    (3.8)| 163| 362
 | 4-pair, 24 AWG| 0.190                    (4.8)| 101| 225
 | 25-pair, 24 AWG| 0.410                  (10.4)| 21| 48
COAXIAL| RG58/U| 0.195                    (5.0)| 96| 214
RG59/U| 0.242                    (6.1)| 62| 139
 | RG62/U| 0.242                    (6.1)| 62| 139
 | RG6/U| 0.270                    (6.9)| 50| 111
TWINAXIAL| 100 Ohm| 0.330                    (8.4)| 33| 74
SHIELDED| TYPE 1| 0.390                    (9.9)| 24| 53
TWISTED PAIR| TYPE 2| 0.465                  (11.8)| 16| 37
TYPE 3| 0.245                    (6.2)| 61| 135
FIBER| Mini ZipCord| 0.079 x 0.157 (2 x 4)| 232| 516
 | ZipCord| 0.118 x 0.236 (3 x 6)| 103| 230
 | Round 4 Strand Fiber| 0.187                   (4.8)| 104| 233
 | Round 6 Strand Fiber| 0.256                   (6.5)| 55| 124

NOTE:
Capacity range is calculated at 20% to 40% of the raceway area as stated in a proposed revision to the Commercial Building Standard for Telecommunication Pathways & Spaces, TIA/EIA-569. Actual wire fill capacity may vary based on applications, cable types, and number, as well as type of fittings. (Fitting may cause additional variances to the fill capacity.)

Category 6 augmented (6a) cable for 10-gigabit ethernet – max allowed cable diameter per addenda No. 11 ANSI TIA/EIA 568-B.2.

Ordering Information

6000 Series Raceway Ordering Information

legrand-G6010B-6000-Series-Blank-End-Fitting-fig-
\(6\)legrand-G6010B-6000-Series-Blank-End-
Fitting-fig- \(7\)

  • 4000C and 6000C are compatible with 4000B and 6000B Raceway.
  • G6001DA Divider Clips are required to hold the divider in place.

4047 Series Cover Plates Ordering Information

legrand-G6010B-6000-Series-Blank-End-Fitting-fig-
\(8\) legrand-G6010B-6000-Series-Blank-End-
Fitting-fig- \(9\) legrand-G6010B-6000-Series-
Blank-End-Fitting-fig- \(10\)

NOTE: Faceplates can also be used with 6000 Series Raceway.

  • Add “C” prefix to denote Canadian version – UL Listed to
  • U.S. and Canadian Safety Standards.

4047 Series Configurable Cover Plates Number Logic

legrand-G6010B-6000-Series-Blank-End-Fitting-fig-
\(11\)

4000 Series Faceplates Ordering Information

legrand-G6010B-6000-Series-Blank-End-Fitting-fig-
\(12\)

Communication Endplates Ordering Information

Communication Endplat| es| Ordering Information|
---|---|---|---
Catalog No./Item| Description/Specifications|  | Catalog No./Item| Description/Specifications|
ARA- **S2***


| Angled Raceway Adapter – For use with 4050 device brackets and WallSource device mounting brackets. Angled exit provides additional mounting depth required for A/V connections as well as ensuring the required bend radius for UTP and fiber optic cabling.

Holds two Ortronics® Series II modules.Fits 5507 Series Faceplate opening.

| **CM-EPLA***


| End Plates – Includes two outlet identification labels with clear covers and two matching screw covers. Required for mounting Pass & Seymour® Activate and

Wiremold CM2 Series Open System communication modules into 4050 Series device brackets.

|
**S2-EPL***

| End Plates – Includes two outlet identification labels with clear covers and two matching screw covers.

Required for mounting Ortronics Series II modules into 4050 Series device brackets.

|
**CM-ARA***


| Angled Raceway Adapter – For use with 4050 device brackets and WallSource device mounting brackets. Angled exit provides additional mounting depth required for A/V connections as well as ensuring the required bend radius for UTP and fiber optic cabling.

Holds two Wiremold CM2 Series Open System modules or two Pass & Seymour® 2A inserts. Fits the 5507 Series Faceplate opening.

|
 |

  • Add a “G” suffix to indicate a gray finish.

V/G4050 & 5507 Series Faceplates Ordering Information

legrand-G6010B-6000-Series-Blank-End-Fitting-fig-
\(17\)

NOTE: All faceplates are 4 1/4″ long x 1 11/16″ wide (108mm x 43mm).

  • Add a “G” suffix to indicate a gray finish.
  • Not for use with 4047BF and 4047RF Device Covers.

NOTE:
All brand and product names referenced in this document are registered trademarks or trademarks of their respective holders.

NOTE:
The paper used to print this document is an environmentally responsible paper with 10% post-consumer waste, with FSC and SFI Chain of Custody certifications, Lacey Act complaint. 100% of the electricity used to manufacture Flo sheets is generated with Green-e-certified renewable energy.

ED530R18 – Updated April 2017 – For the latest specs visit www.legrand.us/wiremold.

Electrical Wiring Systems

  • 60 Woodlawn Street West Hartford, CT 06110

  • Phone: 1.877.BY.LEGRAND (295-3472)

  • www.legrand.us
    570 Applewood Crescent Vaughan, Ontario L4K 4B4

  • Phone: 905.738.9195

  • www.legrand.ca.

© Copyright 2017 Legrand All Rights Reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals