METZ CONNECT 130B117003-E Modul REG Plus IP20 Unequipped Instruction Manual

June 13, 2024
METZ CONNECT

**METZ CONNECT 130B117003-E Modul REG Plus IP20 Unequipped Instruction Manual


**

NOTE

Read Icon
Avoid connection errors!

Read installation instructions carefully before connecting!

Suitable modules and FO Couplers

Version Part No.
C6Amodul 180° 130B11-E
C6Amodul 270° 130B12-E
E-DATmodul Cat.6A 8(8) T568A 130910-I
E-DATmodul Cat.6A 8(8) T568B 130910-I-B1
E-DATmodul Kupplung / Coupler / Coupleur 8(8) 180° 1309A0-I
E-DATmodul Kupplung / Coupler / Coupleur 8(8) 90° 1309A1-I
UAEmodul Cat.6 T568A 130909-I
UAEmodul Cat.6 T568B 130909-I-B1
UAEmodul Cat.5e 8(8) T568A 130908-I
UAEmodul Cat.5e 8(8) T568B 130908-I-B1
OpDAT E2000DC MM, beige 1509005A-I
OpDAT E2000DC SM, blau / blue / bleu 1509005B-I
OpDAT E2000DC SM APC, grün / green / verte 1509005C-I
OpDATmodul LC (PH-Br) MM, beige 15091070-I
OpDATmodul LC (Ker.) SM, blau / blue / bleu 15091071-I
OpDATmodul LC (Ker.) MM, aqua 15091072-I
OpDATmodul LC MM, violett / violet / violet 15091075-I
OpDATmodul LC SM APC, grün / green / verte 15091076-I
OpDATmodul ST 15091001-I
F-jack 130898-01-I
 IEC-jack 130898-02-I

Description

  • unequipped termination unit for mounting on TH35 rail to DIN EN 60715
  • for one individual module in Modul design
  • variable cable feed 45° from the top or bottom,
  • plug direction 45° downwards
  • width of 1HP allows mounting up to 12 REG in standard electrical distribution panels
  • when mounted as a device of protection class I, the equipotential bonding is realized directly over the rail by means of an integrated equipotential plate. Special measures have to be taken to integrate the rail in the equipotential bonding of the building.
  • a cover protects the device against direct contact. If mounted in distributor panels with protective insulation, protection class II is guaranteed. In this case, it is necessary to remove the equipotential bonding plate.
  • integrated dust protection cover (also colored)
  • suitable modules for cable access 45° from the top: C6Amodul 180°, E-DAT modul 8(8), E-DAT modul coupler 180°, UAE modul Cat.5e and Cat.6, OpDAT modul LC-D and ST, OpDAT E2000 DC couplers an coax modules
  • suitable modules for cable access 45° from the bottom: C6Amodul 270° and E-DAT modul coupler 90°
  • not suitable for modules in Keystone design and C6Amodul 90°!

NOTE

Symbol
More detailed information and documentation such as data sheet are available as download at
www.metz-connect.com

Mounting Preparation

Fig. 1: Grounding / Potential balance
The modules are directly grounded to the mounting rail by the potential balance sheet. The mounting rail is connected to the potential balance by a ground clamp. The mounting rail needs to be electrically conductive.
Mounting Preparation
Fig. 2: Isolated Mounting
If the module is to be mounted without grounding, bend the mounting latches on both sides of the lower housing part inwards into the housing…
Mounting Preparation
Fig. 3: … and remove the potential balance sheet with a screw driver. The potential balance sheet is no longer usable after removal.
Mounting Preparation

Mounting of Modules/Couplers 180°

Fig. 1: For cable top entry click the lower housing part onto the mounting rail with the opening showing upwards.

Fig. 2: Insert the terminated module into the upper housing part.

Fig. 3: Put the upper housing part with the module onto the lower part and engage it with pressure on top 1 and bottom 2.

Mounting of Modules/Couplers 270°

Fig. 1: For cable entry from below click the lower housing part onto the mounting rail with the opening showing downwards.

Fig. 2: Insert the terminated module into the upper housing part.

Fig.   3: Put the upper housing part with the module onto the lower part and engage it with pressure on top 1 and bottom 2.

Disassembly of Modules/ Couplers

Fig. 1: Unclip the upper housing part on top with a screw driver ..
Fig. 2: … and remove the upper housing part with the module from the lower housing part.

Fig. 3: Use a screw driver to press down the metal locking latch at the bottom of the module and remove the upper housing part.

Mounting of FO Couplers

Fig. 1: Click the lower housing part onto the mounting rail with the opening showing upwards.

Fig. 2: Remove the dust protection 1 and insert the FO coupler 1 into the upper housing part.

Fig. 3: Put the upper housing part with the module onto the lower part and engage it with pressure on top 1 and bottom 2.

Disassembly of FO Couplers

Fig.   1: Unclip the upper housing part on top with a screw driver …

Fig. 2: … and remove the upper housing part with the module from the lower housing part.

Fig. 3: Use a screw driver to press down the metal locking latches on top and bottom of the module and pull the coupler out of the upper housing part.

METZ CONNECT GmbH | Im Tal 2 | 78176 Blumberg | Germany
Phone +49 7702 533-0 | Fax +49 7702 533-433
Weitere technische Dokumentationen siehe / For more technical documentation see/ Plus de documentation technique à télécharger sur www.metz- connect.com

METZ CONNECT Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals