planika FKE-0890 Arcticon Fireplace Instruction Manual

June 13, 2024
planika

planika FKE-0890 Arcticon Fireplace

Product Information

  • Product Name: Arcticon Fireplace
  • Languages: EN, DE, ES, FR, IT, PL, RU
  • Manufacturer: Planika Sp. z o.o.
  • Website: www.planika.com
  • Model Number: I1510#06
  • Copyright: Planika Sp. z o.o.
  • Date: 25.04.2023

Product Usage Instructions

WARNING: The product is a decorative device with real fire. Read the included documentation prior to installing and operating the device. Check the local regulations for fireplaces.

Installation

  1. Plug the cables into the sockets at the bottom of the fireplace. Pull the cable with the plug through the opening at the back of the appliance.
  2. Install the bracket J1 to the wall and J2 to the back wall of the fireplace using added bolts. Lift the fireplace and place it on the wall bracket. Attention! The fireplace must stand on legs and not hang.
  3. Place the granules (E, F) evenly in the marked area leaving no uncovered area. Use one bag (F) to cover the burner. Distribute the remaining bag (E) around the ventilation mesh. Make sure the granules are not in contact with the filament. Do not place the granules on the ventilation mesh.

Product Components

Component English Deutsch Español Français Italiano Polski Русский
Fireplace housing A Obudowa kominka Carcasa de la chimenea Boîtier de
cheminée Alloggiamento del caminetto Obudowa kominka Торговый автомат
Front glass C Frontglas Vidrio frontal Vitre avant Vetro anteriore
Przednia szyba Переднее стекло
Service cable D Service -Kabel Cable USB de servicio Câble de service
Cavetto per l’assistenza technica Kabel serwisowy Сервисный кабель
Bag with granules (E) E, F Tasche mit dem Granulat Sacchetto per granuli
Sac avec des granulés (E) Sacchetto per granuli (E) Torba z granulatem (E)

Мешок с гранулами (E)
Side glass| G| Seitenglas| Vetro laterale| Vitre latérale| Boczna szyba| Боковое стекло
Power cable| H| Stromkabel| Cable de alimentación| Câble d’alimentation| | | Силовой кабель
Remote control| I| Fernbedienung| Mando a distancia| Télécommande| | | Пульт дистанционного управления
Mounting bracket (J1, J2)| J1, J2| Montagewinkel| Soporte de montaje| Support de montage (J1, J2)| | | Крепежный уголок (J1, J2)
Not supplied by producer| | Nicht vom Hersteller geliefert| No suministrado por el fabricante| Non fourni par le fabricant| | | Не поставляется производителем

WARNING
This manual only applies to the installation and operation of dedicated burner in Arcticon firebox only.

The product is a decorative device with real fire.
Read the included documentation prior to installing and operating the device. Check the local regulations for fireplaces.

  1. For indoor use and in housing only. Min. temperature of use is 10°C.
  2. Room cubature for one device – min. 35 m3.
  3. Natural air exchange rate in room – min. 1/h.
  4. Do not use the device in humid and drafty spaces.
  5. Do not cover top ventilation openings of the device.
  6. Do not place any objects on the top of the device.
  7. We recommend placing a CO2 or dry powder fire extinguisher nearby the device
  8. For service purposes, the surrounding must allow for easy removal of the device.
  9. Keep children, animals and unauthorized persons away from the device.
  10. Keep the packaging and manuals for future use.
  11. Do not turn on the device in case of fuel spill.
  12. Do not interfere in the fuel filler when the device is operating.
  13. Do not interfere in the device construction.
  14. Do not touch the filament and other hot elements.
  15. Do not transport the device if fueled.
  16. Do not leave an operating device unattended

Dimension

planika-FKE-0890-Arcticon-Fireplace- \(2\)

  EN
A. Fireplace housing
B. Fuel container
C. Front glass
D. Service cable
E. Bag with granules
F. Bag with granules
G. Side glass
H. Power cable
I. Remote control
J. Mounting bracket
K. Mounting screws

Plug the cables into the sockets at the bottom of the fireplace. Pull the cable with the plug through the opening at the back of the appliance.

planika-FKE-0890-Arcticon-Fireplace- \(3\)

Place the fuel container in place and screw on the cap with the fuel hoses.

planika-FKE-0890-Arcticon-Fireplace- \(4\)

Install the bracket J1 to the wall and J2 to the back wall of the fireplace using added bolts. Lift the fireplace and place it on the wall bracket. Attention! The fireplace must stand on legs and not hang.

planika-FKE-0890-Arcticon-Fireplace- \(5\)

Mount the door. Level the appliance by adjusting the appliance feet.

planika-FKE-0890-Arcticon-Fireplace- \(6\) planika-
FKE-0890-Arcticon-Fireplace- \(7\)

Place the granules (E, F) evenly in the marked area leaving no uncovered area. Use one bag (F) to cover the burner. Distribute the remaining bag (E) around the ventilation mesh. Make sure the granules are not in contact with the filament. Do not place the granules on the (VENTILATION MESH)

NOTE! Make sure the device is turned off and the glass shields have cooled down to room temperature. Place the shield so the top edge fits in the top frame space, then place its bottom edge in the bottom frame space. Lower the glass shield vertically down. Proceed with the remaining glass shields.

planika-FKE-0890-Arcticon-Fireplace- \(8\)

Wanring! hot air outlet, do not place any objects on the ventilation grid of the fireplace.

EN

1. Filament
2. Burner
3. Device surface
4. Control panel
5. Cap with a pumping hose
6. Fuel container

planika-FKE-0890-Arcticon-Fireplace- \(11\)

EN

  • ECO mode

  • Flame ignition / flame extinguishing

  • Service socket

  • Control diodes

  • Diodes OFF

  • Diodes ON

  • Blinking diodes

REPLACING FUEL CONTAINER

  1. If the fuel container is empty ( ), unscrew the cap with the pumping hose and remove the container from the  holder (I).
  2. Insert a full fuel container with a cap removed.
  3. Screw the cap with the pumping hose back on (III).

planika-FKE-0890-Arcticon-Fireplace- \(20\)

FLAME IGNITION

The green diode indicates that the device is ready to ignite the flame.
Press and hold START for 3 seconds. Flame ignition will take 2-10 minutes ( ). The smell of ethanol vapours  can be present during the ignition. The diode READY off ( ) indicates that the flame has been ignited and the device reached the working temperature.

FLAME HEIGHT REGULATION

After 3 min, press ECO to lower the flame (two sound signals). Press ECO again to increase the flame height (one sound signal).
ATTENTION! In case the device temperature is too high, the flame will be automatically lowered (ECO) and the height regulation blocked. If the temperature keeps increasing, the device will be turned off.

FLAME EXTINGUISHING

Press STOP to extinguish the flame (sound signal + ).
You can ignite the flame again when the device is cooled – the green diode READY ( )

FAST START

The FAST START offers faster flame ignition (when the device is ready ( ), the power consumption is 60 W higher). The function is enabled by default.
To disable FAST START, press and hold ECO for 10 seconds (four sound signals). To enable the function, press and hold ECO for 10 seconds (two sound signals).

TROUBLESHOOTING

Some alarms are accompanied by a sound signal. Press START/STOP to mute.

Lp.| DIODES| SOLUTION

(contact the Service Department if the solution does not eliminate the error)

---|---|---
1.| | The device is being cooled. Wait for the green diode .
2.| | The device run out of fuel while operating. The device is being cooled. Wait for the red diode to turn off. Refill the tank.

| | An internal fuel spill occurred. Disconnect the pump. Wipe the visible liquid and wait for min. 1 hour. Press and hold ECO on the control panel for 10 seconds. If the error is not eliminated, wait for min. 24 hours.
If the error occurred during flame ignition, it means that the ignition time has been exceeded. Press and hold ECO on the control panel for 10 seconds.
4.| | Device error. Press and hold ECO on the control panel for 10 seconds.
5.| | Tank overfilled. Contact the Service Department.
6.| | Room temperature too low (<10°C) or device error. Increase the room temperature.
Press and hold ECO on the control panel for 10 seconds. Wait for the green diode .
7.| | Device overheat. Please contact service department.

FUEL – Use only ethanol fuel produced from plants in the process of two- time alcohol distillation consisting of 95-96.6% ethanol by volume. Fanola is the recommended fuel with pharmacological purity.
DO NOT USE SYNTHETIC PETROLEUM BASED FUELS AS THEY ARE CONTAMINATED, EMIT UNPLEASANT ODORS AND CAN DAMAGE THE FIREPLACE! DO NOT USE FUELS CONTAINING 100% ETHANOL BY VOLUME, GEL, OR AROMATIC FUELS!
CLEANING – Clean with a damp cloth and delicate detergents, only when the device is turned off and cooled.
SERVICE – Keep the provided USB cable for service. Reach out to us at service@planikafires.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals