Endon 106923 Pendant Light Fitting Instruction Manual

June 13, 2024
ENDON

Endon 106923 Pendant Light Fitting

Endon-106923-Pendant-Light-Fitting-product

Product Information

The Pendant Light Fitting is a Class I product that must be Earthed. It is suitable for domestic ceiling use only and should not be installed in a bathroom location. The product is designed for connection to a 220-240V~ 50Hz power supply in accordance with current IEE wiring regulations and local building regulations. The terminal blocks are supplied according to the requirements of the fitting.

It is important to note that nothing should be placed on the product or hung on any part of it. Bulbs of a higher wattage than specified on the label should not be used as they may cause overheating and damage the fitting. The product should not be disposed of with household waste; please recycle it where facilities exist. For any care and maintenance, switch off the product, allow it to cool down, and clean it with a dry cloth only. Liquid or abrasive cleaners should not be used.

Product Usage Instructions

  1. Before installation, read through the safety instructions thoroughly and retain them for future reference.
  2. If you are unsure about installing the product, consult a qualified electrician.
  3. Ensure that the power supply is a 220-240V~ 50Hz connection and meets the current IEE wiring regulations.
  4. Install the Pendant Light Fitting in accordance with local building regulations.
  5. Make sure the product is only used for domestic ceiling applications and not in a bathroom location.
  6. Ensure that the product is Earthed properly.
  7. Do not place anything on the product or hang anything on any part of it.
  8. Use bulbs with wattage specified on the label, avoiding higher wattages to prevent overheating and damage to the fitting.
  9. Dispose of the product responsibly by recycling it where facilities exist.
  10. For bulb replacement, switch off the product and allow it to cool down before replacing the bulb. Use a dry cloth to clean the product; do not use liquid or abrasive cleaners.
  11. If the bulb does not light after installation, check for electricity failure and ensure all connections are secure. Consult a qualified electrician if there are any doubts about the installation or use of the product.

Safety Warnings

  • These instructions are for your safety. Please read through them thoroughly before use and retain them for future reference. If you are in any doubt about installing this product, consult a qualified electrician.
  • This product is only suitable for connection to a 220-240V~ 50Hz supply in accordance with current IEE wiring regulations and should be installed in accordance with local building regulations. It is for domestic ceiling use only and is not suitable for a bathroom location.
  • This is a Class I product and must be Earthed. The terminal blocks are supplied according to the requirements of the fitting.
  • IMPORTANT: Always switch off the mains supply during installation or maintenance. We recommend that the fuse is withdrawn or the circuit breaker switched off at the distribution board whilst work is in progress (turning off the light switch is not sufficient). Connection should be via a wall switch to enable safe isolation.
  • The product must be securely fixed to the mounting surface using the screws and wall plugs supplied. The screws and wall plugs supplied are suitable for “masonry” only. Other fixings are not supplied and must be purchased.
  • Decide on the position of the light fitting or remove the existing light fitting. Note the position of the electrical connections, and ensure there is a solid mounting surface, Preferably a wooden joist or joist bridge, to support the weight of the light fitting.
  • Take care not to drill into any pipes or main cables beneath the surface during mounting hole preparation.
  • Never put anything on the product or hang anything on any part of this product.
  • IMPORTANT: Ensure that all electrical connections are tight and that no loose strands are left out of the terminal.
  • Never fit bulbs of a higher wattage than those specified on the label (as these may cause overheating and damage the fitting).
  • Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or local store for recycling advice.

Care and maintenance

  • For bulb replacement, switch off the product (preferably, isolate it at the distribution board) and allow it to cool down (Caution: bulb gets hot during use).
  • Clean with a dry cloth only. Do not use liquid or abrasive cleaners on this product.

Troubleshooting

When the bulb does not light after installation:

  • Ensure there is no electricity failure.
  • Ensure all the connections are secure.

If you have any doubt about the installation/use of this product, consult a qualified electrician.

Assembly Instructions

Endon-106923-Pendant-Light-Fitting-fig-1

Scan QR code for multi-lanquage

Documents / Resources

| Endon 106923 Pendant Light Fitting [pdf] Instruction Manual
106923 Pendant Light Fitting, 106923, Pendant Light Fitting, Light Fitting, Fitting
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals