Truma AquaGo Desired Water Temperature Instructions
- June 13, 2024
- Truma
Table of Contents
Truma AquaGo Desired Water Temperature
Product Information
The Truma AquaGo is a water heater system designed for use in recreational vehicles (RVs). It requires periodic decalcification to maintain optimal performance. The decalcification process involves using special tablets to remove mineral deposits from the system.
Product Usage Instructions
- Ensure that you have access to city water for the cleaning process.
- Turn off the city water supply and allow the system to cool off.
- Locate the toggle switch on the outside of the RV and turn off the Truma AquaGo.
- Inside the RV, open a hot water faucet to depressurize the system and drain the water. Close the faucet once water stops flowing.
- Return to the Truma AquaGo unit outside the RV. Stand to the side and slowly pull down the yellow Easy Drain Lever to remove the filter.
- Open the decalcification tablet pack and insert all 6 tablets into the filter screen.
- Place the filter loaded with the decalcification tablets back into the water heater, close the yellow lever, and snap it in place.
- Turn on the city water supply.
- On the outside of the RV, turn the AquaGo toggle switch to the on position.
- Select a faucet with the highest pressure and a removable screen/aerator. Remove the screen to prevent clogging and ensure accurate flow measurement during the rinse cycle.
- Inside the RV, turn on a hot water faucet to purge air from the lines. The water may appear pink, which is normal. Turn off the faucet.
- During the cleaning cycle, the circulation pump will intermittently turn on. This is normal. The decalcification process will take approximately 2 to 3 hours and cannot be sped up or canceled once started.
Analog Dial Control Module:
Follow these additional steps if your Truma AquaGo uses the Analog Dial control module:
- After depressurizing the water system, turn the analog dial to the Clean mode. The amber light will blink slowly during the cleaning process.
- If you wish to cancel the cleaning process, you have 30 seconds to turn the analog dial away from Clean mode. After 30 seconds, the circulation pump will turn on and the decalcification process will begin, even without decalcification tablets in the filter.
- Once the cleaning process is complete, the amber light will blink rapidly.
- Turn the analog dial to the Off position. On the outside of the RV, turn the AquaGo toggle switch to the off position and wait for 1 minute.
- Turn the AquaGo toggle switch to the on position and then go inside and turn on the analog dial.
- Slowly turn the analog dial from Off to Comfort, to Eco, back to Off, and then to Eco again. Repeat this process if necessary until you see a solid amber light, indicating successful activation.
CP Plus Controller:
Follow these additional steps if your Truma AquaGo uses the CP Plus Controller:
- After depressurizing the system, turn the dial on the controller until the wrench icon is selected. Push the center button.
- Turn the dial to select AquaGo and push the center button.
- Continue turning the dial until you see Clean and push the button to activate the cleaning mode.
If you require further assistance, please contact Truma customer service:
- Email: service@trumacorp.com.
- Phone: 1-855-558-7862 ext1
- Address: 2800 Harman Drive, Elkhart, IN 46514
Truma AquaGo Decalcifi cation Instructions
Please use city water for the cleaning process to ensure you have enough water
to complete cleaning process. To start the decalcifi cation process please
follow these steps:
- Turn off city water and allow the system to cool o .
- Turn off Truma AquaGo at the toggle switch on the outside of the RV.
- Go inside the RV and open hot water faucet to allow system to depressurize and water to drain. Wait until water stops fl owing out of faucet and then close the faucet.
- After system is depressurized, go back outside to the Truma AquaGo. Stand o to the side and slowly pull the yellow ”Easy Drain Lever” down and remove the fi lter.
- Open the decalcifi cation tablet pack and insert all 6 tablets into the fi lter screen.
- Place the fi lter loaded with the decalcifi cation tablets back into the water heater, close the yellow lever, and snap in place.
- Turn on city water.
- On the outside of the RV, turn the AquaGo toggle switch to the “on” position.
- Choose a faucet with the highest pressure and a removable screen/aerator for this process. Remove the screen so debris being fl ushed during the rinse cycle will not clog the faucet screen and the fl ow sensor can read the gallons per minute accurately.
- Go inside and turn on a hot water faucet. Allow the air to be purged from the lines.
The water coming out of the faucet may be pink in color, this is normal. Turn faucet off . During the cleaning cycle, the circulation pump will turn on intermittently, this is normal. The decalcifi cation process will take roughly 2 to 3 hours. There is no way to speed up this process or cancel after it has started. From here, the decalcifi cation process will depend on which control module your Truma AquaGo uses. Please refer to the instructions for your control module below.
Analog Dial
To the right is a picture of the analog dial with an amber backlight. After depressurizing the water system, turn the analog dial to “Clean” mode. During the cleaning process, the amber light will blink slowly. When the analog dial is turned to “Clean” mode, you have 30 seconds to cancel the cleaning process. After 30 seconds the circulation pump will turn on and the decalcifi cation process will begin, even if there are no decalcifi cation tablets in the fi lter. After the cleaning process is complete, the amber light will blink rapidly.
- Once light blinks rapidly this means that the unit is ready to fl ush. You will use the hot water faucet with the highest pressure and a removable screen/aerator for this process. Turn the faucet on and fl ush approximately 8 gallons of water through the system. Once enough water has fl ushed through, the light will stop blinking rapidly and blink two times with a pause. There will be a blinking red LED light below the toggle switch on the outside of the AquaGo. Red LED light will blink 8 times in the sequence of S,S,S,L, L,L,L,L. This is fault code 31 “Decalcifi cation Complete”.
- Turn the analog dial to “Of .” On outside of the RV, turn the AquaGo toggle switch to the “of ” position. Wait 1 minute.
- Turn the AquaGo toggle switch to the “on” position and then go inside and turn the analog dial on.
- Slowly turn the analog dial from “Of ,” to “Comfort,” to “Eco,” back to “Of ” and then to “Eco” again. You may have to do this a few times to “wake the dial up.” You will get a solid amber light when this is successful.
CP Plus Controller
To the right is a picture of the CP x controller. After depressurizing the system, follow the instructions below to initiate the AquaGo cleaning mode.
- Turn dial until the wrench icon is selected and push the center\ button, turn dial to select AquaGo and push the center button,turn the dial until you see “Clean,” and push the button to activate cleaning mode.
- The screen will say “clean” while decalcification is in progress.
- The screen will say “rinse” when the cleaning process is complete.
- You will use the hot water faucet with the highest pressure and a removable screen/aerator for this process. Turn the faucet on and flush approximately 8 gallons of water through the system.
- Once the rinse cycle has been completed, an “E31” code will appear to indicate that the decalcifcation is complete. Turn of the water.
- Push the center button twice to revert to the main screen and resume normal operation.
- On the outside of the RV, turn the AquaGo toggle switch to the “of ” position. Wait 1 minute. Turn back on.
Resetting the CP plus
If there are multiple Truma appliances connected to the CP plus you will need
to reset the CP Plus to get the other device(s) to back online.
- Turn dial until the wrench icon is selected and push the center button.
- Turn the dial until “Reset” is selected and push the center button.
- The screen will say “PR SET,” push the center button again.
- The screen will say “INIT,” which means the system is initializing. When complete, the screen will return to a digital clock.
AquaGo stuck in clean mode
- The Truma AquaGo must have power from the main panel.
- The outside toggle switch on the AquaGo needs to be in the “On” position.
- Turn the analog dial to “Clean” mode (this is the bottom position on the dial)
- Wait until you hear the circulation pump cycle on and of . You may need to “wake the dial-up” by turning it on and of a couple of times until you hear the circulation pump cycling.
- Open a hot water faucet, let the water run until the amber light on the analog dial stops flashing. This could take 15 minutes or more. During this time, you will hear the circulation pump turning of and on intermittently. This is normal and the burner will not ignite.
- Once the fl ush cycle is complete, the green LED above the toggle switch on the outside of the AquaGo, will go of . You will see a red LED light fault code below the toggle switch. This is fault code 31 (S,S,S,L,L,L,L,L) “Decalcifi cation Complete”.
- Turn the toggle switch on the AquaGo to the “of ” position.
- Go inside and turn the analog dial to the “of ” position and wait 30 seconds.
- Turn the toggle switch on the AquaGo back on- solid green light should be present
- Turn the analog dial to the “ECO” or “Comfort” mode. You may need to “wake the dial up” by slowly turning it on and of a couple times. The unit should work normally at this time.
CONTACT
- service@trumacorp.com.
- 1-855-558-7862 ext1
- 2800 Harman Drive, Elkhart, IN 46514
Read User Manual Online (PDF format)