Connected acoumeter
Wi-Fi
Ethernet
The acoumeter can be used offline without an internet connection (directly on the product screen), or can be added to a “with Metaatom” connected installation and managed via the Home + Control app.
Optional “with Metaatom” starter pack
ou ou …
There is no need to install a “with Metaatom” starter pack to use the
connected acoumeter via the Home + Control app.
However, the acoumeter is not a gateway. If you wish to add other “with
Metaatom” connected products, you will need to install a starter pack that
includes a gateway power module, a gateway power outlet or all other
connection interface «with Metaatom».
Composition
Connected acoumeter
The connected acoumeter must be used with measurement coils Cat. No 4 120 08 (5 maximum)
Connected acoumeter pack
This pack contains unconnected acoumeter + Measurement coils (x3)
Measurement coil
Pay attention to the current direction
EC directive
Complies with the following European directive:
Low-voltage directive (LVD) 2014/35/EU
Electromagnetic compatibility (EMC) no. 2014/30/EU
| | IMAXE| |
---|---|---|---|---
5°C +45°C| 100 – 240 V~ 50/60 Hz| 80 A| 2.4 to 2.4835 GHz < 100 mW| ±1% at 63
A
- **Measurement
**
-
Total
-
Electric heating and air conditioning
-
Domestic hot water
-
Sockets
-
Other (lighting, EV sockets, etc)
-
Gas
-
Hot water
-
Cold water
Characteristics
Pulse meters (not supplied)
- Continuous red indicator lamp: product awaiting commissioning and connected via Ethernet link
- Flashing green: product awaiting commissioning and connected via Wi-Fi or not
- Slow flashing green: CIS mode connected and data received from the CIS
- Fast flashing green: CIS mode disconnected or data not received from the CIS
Step-by-step installation
Choose a location for the connected acoumeter in the electrical panel
The ecometer is connected on Wi-Fi or via an Ethernet cable (RJ 45 cable).
Wi-Fi connection
If the home has a router, use a smartphone to check that the Wi-Fi signal is
strong enough. If not, try and put the router closer to the electrical panel,
add a Wi-Fi repeater or connect the acoumeter to your router with an Ethernet
cable.
Imperative security precaution
The instructions for installation and use must be strictly observed in order to avoid the risk of electric shock or fire.
Mounting, wiring
Turn off the power at the main switch(main circuit breaker)
Pulse input MAX
1x 1.5 mm²
2x 1 mm²
N, L : MAX
1x 2.5 mm²
1x 1.5 mm²
Pulse input N, L:
MAX: 0.5 Nm
**3.5 mm
**
Protecting the device
The connected ecometer must be protected by a circuit breaker or a fuse rated
2 A.
Pay attention to the current direction
An arrow on the coil indicates the correct current direction.
Installation without CIS connection
If the CIS (Customer Information System) is not connected (default scenario):
the total consumption measurement will come from the coil connected to the
“Total (5)” input.
If the CIS (Customer Information System) is connected and working: the total
consumption measurement will come from the CIS (to be connected). The coil
connected to the “Total (5)” input can then feed back consumption data from a
separate circuit.
NB : Each input can easily be assigned to a personalised consumer source in the Home + Control app.
Complete installation in the Home + Control app
Download the Home + Control app.
Create an account and follow the instructions.
NB : If you already have a “with Netatmo” connected installation, simply go to Settings in your Home + Control app, “Add device” section.
Installing the ecometer offline
If you don’t have a smartphone or you don’t want to connect your ecometer to
the internet, you caninstall it in offline mode by performing the steps below.
You then need to configure the device offline by scrolling through the
different screens using the thumbwheel on the front of the device:
NB : Choosing offline installation will not prevent you adding the ecometer to your connected installation in the Home + Control app at a later date.
Configuring the date and time
-
Go to the MENU by clicking on the thumbwheel
-
“Settings” section
-
“Date & Time” section
-
Set the ecometer date and time
Personalizing the inputs
Electricity consumption rows
-
Go to the “Inputs” section
-
Rename the electricity consumption rows if you wish (rows 1 to 5)
Gas input
- Set the pulse coefficient for your gas meter.
- This information is usually stated on your gas bill.
Setting the currency and tariffs
-
Go to the “Currency and tariffs” section
-
Select the desired currency ($ or €)
Electricity tariffs
-
To set your electricity contract tariff, select “Tariffs” then “Electricity”.
-
Set the Base tariff by entering the cost per kWh stated for example on your Electricity contract, on one of your bills or on your energy supplier’s online interface.
If you have subscribed to a Peak/Off-Peak contract, the electricity tariff varies according to the time of day. Enter the peak and off-peak tariffs per kWh, then create as many time slots as necessary to fill in the off-peak times for your electricity contract.
This information is usually stated on your contract, on one of your bills or on your energy supplier’s online interface.
Water contract tarif
-
Enter the cost per m3 of water stated on your contract (field accessible from the Tariffs menu).
-
Enter the cost per m3of gas stated on your contract (field accessible from the Tariffs menu).
Your ecometer is ready!
Direct reading on-screen
Turn the thumbwheel to select a day
Detailed consumption (per source)
View daily, monthly or annual total consumption.
**Instantaneous power
**
Scan your Home Kit code
While installing the iOS mobile app, you will be asked for this code.
-
Go to the MENU by clicking on the thumbwheel
-
“Settings” section
-
Section “Apple Home Kit Code”
-
Scan your Home Kit code or manually enter the code indicated on-scre
NB : The code in this manual does not represent your HomeKit code (graphic for illustration only)
Home Kit
To control this Home Kit-compatible accessory, we recommend using the latest version of iOS or iPad OS. In order to control this Home Kit accessory automatically from outside the home, you need a Home Pod, Apple TV or iPad configured as a hub. It is advisable to update to the latest version of both the software and the operating system.
Disclaimer
Where devices bear the Apple Home Kit logo, this means that an electronic
accessory has been designed to connect specifically to the iPod, iPhone or
iPad, and has been certified by the developer to meet Apple’s performance
standards.
Apple is not responsible for the operation of this device or its compliance
with safety and regulatory standards. Please note that using this accessory
with the iPod, iPhone or iPad may affect wireless performance.
iPhone, iPod and iPad are trademarks of Apple Inc, registered in the United
States and other countries.
App Store is a trademark of Apple Inc, registered in the United States and
other countries.
Home Kit and iPad OS are trademarks of Apple Inc. iOS is a trademark of Cisco
registered in the United States and other countries and used under license.
Android, Google Play and the Google Play logo are trademarks of Google LLC.
Resetting the ecometer
Via the Home + Control app
To clear your acoumeter and restore its factory settings, go to Settings in
your Legrand Home + Control app, “My Home” section, and delete the device.
In offline mode
If you don’t have access to a smartphone, you can reset your acoumeter
directly on the device by following the steps below:
www.legrand.fr/reference/412032
www.legrand.fr/reference/412033
LEGRAND – Pro & Consumer Service – BP 30076
87002 LIMOGES CEDEX FRANCE •
www.legrandgroup.com
SIMPLIFIED EU DECLARATION OF CONFORMITY
The undersigned,
Legrand
declares that the radio equipment referred to in this manual complies with
Directive 2014/53/EU
The full text of the EU declaration of conformity
can be found at the following web address:
www.legrandoc.com
References
- cat.no
- 412032 Ecocompteur modulaire connecté pour mesure consommation sur 5 postes 230V~ - 50/60Hz - 5 modules - professionnel | Legrand
- LEGRAND GROUP - News, Financial, RSE, Careers - Legrand
- Legrand E-catalog International | Electrical Ranges of products & Connected Solutions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>