GENELEC F One Active Subwoofer User Manual
- June 13, 2024
- GENELEC
Table of Contents
- GENELEC F One Active Subwoofer
- Product Information
- Product Usage Instructions
- General description
- Installation
- Operating Environment
- Functions And Controls
- Positioning In The Room
- Matching IR Remote Controls
- Safety Considerations
- Compliance To FCC Rules
- Changing The Remote Control Battery
- Guarantee
- SPECIFICATIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GENELEC F One Active Subwoofer
Product Information
The Genelec F One is a compact active subwoofer designed to complement Genelec G One or G Two active loudspeakers. It extends the system’s bass response down to 35 Hz and integrates perfectly with the main loudspeakers in any environment. The subwoofer has integrated bass management for the two output channels, directing frequencies below 85 Hz to the subwoofer and higher frequencies through the output connectors to the main loudspeakers. It comes with a wireless volume control for convenient playback level control, and a wired volume control is available as an option. The F One is equipped with both analog and digital signal input connectors, allowing for up to four audio sources to be connected simultaneously.
Product Usage Instructions
- Before connecting the audio signals, ensure that all equipment is switched off.
- Check the contents of the shipment. In addition to the subwoofer, there should be a wireless remote control, a mains cable, an IR extension cable, and a Quick Setup guide.
- Connectors:
- Analog Input Connectors: The F One has two stereo inputs (3.5 mm jack and L/R RCA connectors) and an LFE RCA connector. The stereo inputs are parallel, allowing for the connection of two audio sources at the same time. However, only one source can be played at a time. The LFE input is used for the LFE (.1) signal in a 2.1 or 5.1-channel sound system.
- Digital Input Connectors: The F One has two digital signal input connectors – one coaxial and one optical – that accept stereo PCM format digital signals. You can connect two digital sources and switch between them using the Select function.
- MAINS INPUT: Connect the mains cable to the mains input of the subwoofer.
- RCA L AND R AUDIO OUTPUT CONNECTORS: These connectors can be used to connect the subwoofer to the main loudspeakers.
- SUBWOOFER LEVEL ROTARY ADJUSTMENT: Use this adjustment to control the level of the subwoofer.
- SELECT BUTTON: Use this button to switch between different audio sources.
- POWER BUTTON: Use this button to turn the subwoofer on or off.
- ROLL-OFF PHASE: Use the DIP switches in this group to adjust the roll-off phase of the subwoofer.
- SUBW LEVEL: Use the DIP switches in this group to adjust the subwoofer level.
- ISS HT MODE: Use the DIP switches in this group to adjust the ISS HT mode sensitivity and LED status.
For further information and detailed instructions, please refer to the user manual provided with the product.
General description
The Genelec F One is a very compact active subwoofer designed to complement
Genelec G One or G Two active loudspeakers. The F One extends the system’s
bass response down to 35 Hz and integrates perfectly with the main
loudspeakers in any environment. The playback level for the whole system is
conveniently controlled by the wireless volume control provided with the
subwoofer. A wired volume control is available as an option.
The F One has integrated bass management for the two output channels which
directs frequencies below 85 Hz to the subwoofer and higher frequencies
through the output connectors to the main loud speakers. When using the
subwoofer for the .1/LFE channel of a multichannel system, we recommend that
bass management is done in the processor or receiver and only the LFE channel
is connected to the subwoofer.
Installation
Before connecting the audio signals, ensure that all equipment is switched off. As the F One contains its own amplifier, no separate power amplifier is needed. Never connect the F One to the loudspeaker outputs of a power amplifier, integrated amplifier or receiver. Please follow the steps listed below for a succesful setting up of the subwoofer:
- Check the contents of the shipment. in addition to the subwoofer, there is a wireless remote control, a mains cable, an IR extension cable and a Quick Setup Guide.
- Pull out the battery insulating strip from the underside of the remote control as shown in figure 1. This strip insulates the battery from the contacts on the remote control during shipping and the remote control does not function before it is removed.
- Place the subwoofer in its position.
- Connect audio cables from your signal source(s). You can connect up to two digital audio sources and two analog audio sources.
- Connect the main loudspeakers to the output connectors of the subwoofer.
- Adjust the phase of the subwoofer as instructed in this manual and the Quick Setup Guide.
- Use test recordings and familiar music pieces to judge the sound balance. Use the “SUBWOOFER LEVEL” rotary control and the “BASS ROLL-OFF” dip switches to fine-tune the balance. If this fails, consider relocating the subwoofer.
Operating Environment
The F One subwoofer is designed for indoor use only. The ambient temperature should be 15-35 °C (50-95 °F) and the relative humidity 20-80 %. Condensation is not allowed. If it has been stored or transported in a cool environment, the product must be allowed to warm up in its packing to the ambient temperature before connecting mains power.
Connectors
The F One is equipped with both analog and digital signal input connectors,
that can be used simultaneously to connect up to four audio sources (two
analog, two digital). Switching between sources is done with the Select button
on the connector panel or with the “<” and “>” buttons on the remote control.
The colour of the LED light on the subwoofer enclosure indicates which source
is selected.
Analog Input Connectors
The F One has two stereo inputs (3.5 mm jack and L/R RCA connectors) and an
LFE RCA connector. The stereo inputs are parallel, so you can connect two
audio sources at the same time, just play only one of them at a time. The
Select function does not work between these two inputs. The LFE input is used
for the LFE (.1) signal in a 2.1 or 5.1-channel sound system. The LFE input
has a 120 Hz low pass filter, so it is not suitable for full frequency range
signals.
Digital Input Connectors
The F One has two digital signal input connectors, one coaxial and one
optical, that accept stereo PCM format digital signal. You can connect two
digital sources and switch between them using the Select function.
Analog Output Connectors
The F One has RCA analog stereo L/R output connectors. Connect signal cables
from these connectors to the main speakers. These outputs are high pass
filtered at 85 Hz (See chapter Bass Management). information.
System Volume Control Connector
This connector allows connecting the Genelec 9310A Wired Volume Control which
is available as an accessory. When connected, the 9310A controls the volume of
the whole system, including the main speakers.
IR IN Connector
If the F One is used with an infrared type remote control (see chapter Use
with IR Remote Controls) and the desired location of the subwoofer does not
allow an unobstructed line of sight to the receiver located next to the LED in
one of the subwoofer’s feet, the IR extension cable provided with the
subwoofer can be connected here. The receiver end of the cable is then brought
to a location where the IR remote control reception works conveniently, for
instance close to the IR receiver of a television set when using the subwoofer
and speakers with a TV.
Functions And Controls
-
HT Mode
Turn this switch to “ON” when you connect a sound source with its own volume control to the analog inputs of the F One. In this mode the volume control of the F One does not have effect on the analog signals. However, it works with digital inputs, so you can use them to connect other signal sources. -
ISS Sensitivity Low
If the Intelligent Signal Sensing (ISS) function switches the subwoofer on when there is no audio signal present, turning this switch to “ON” reduces the triggering sensitivity of the function. -
ISS
The Intelligent Signal Sensing (ISS) function monitors the audio signal fed to the subwoofer. If there is no signal for approximately 45 minutes, the function switches the subwoofer to Standby mode, reducing the power consumption to less than 0.5 Watts. When the signal resumes, the subwoofer powers up again. There is a slight delay in the automatic powering up. In those environments where the subwoofer is required to be on all of the time, the ISS function can be disabled by setting the “ISS” switch to the “OFF” position. Then the subwoofer is continuously powered and can be turned off using the power button on the remote control or connector panel. -
LED Off
This switch deactivates the status indicator LED on the “foot” of the subwoofer. -
Roll-Off
These two switches attenuate the subwoofer’s bass response below 35 Hz. Attenuation levels are -2, -4 and -6 dB (both switches “ON”). -
Phase
These two switches provide phase adjustment for the subwoofer in -90 degree increments. See chapter “Phase Alignment”. -
Subwoofer Level
This rotary adjustment adjusts the playback level of the subwoofer. The level is increased by turning the adjustment clockwise and reduced by turning it counter-clockwise. -
Select
This button allows signal input selection between the two digital inputs and the analog input and initiation of the matching procedure for IR remote controls (see Matching IR Remote Controls). -
Power
This button switches the subwoofer between Standby and Power mode. Note that this button does not completely disconnect the subwoofer from the mains power. If this is necessary, the subwoofer’s mains cable must be disconnected. This button can also be used for restoring the factory settings by keeping it depressed for 10 – 15 seconds. This returns the volume setting on the remote control to factory level and deletes possible remote control pairing and IR remote control matching. Also the source selection returns to automatic, which is the factory setting.
Positioning In The Room
The placement of the subwoofer in the room affects the overall frequency response and sound level of the system dramatically, as at low frequencies the effects of the room are strong. Even a slight change in the location of the subwoofer can cause a marked difference in the frequency balance and often patient and methodical experimentation and testing is needed to find the optimum placement. The placement will also affect the bass roll-off rate and the phase difference between the main loudspeakers and the subwoofer. These effects can be compensated using the controls in the subwoofer but we recommend that at first you leave the switches untouched and concentrate on finding the position where the subwoofer gives the smoothest response, and only then use the controls to fine-tune the balance and phase alignment between the subwoofer and the main loudspeakers. Start by placing the subwoofer close to the center of the front wall. We recommend a distance of less than 60 cm / 24” to the wall. This position gives increased acoustic loading and sound pressure level due to the proximity of the front wall and floor. Ideally the subwoofer and main loudspeakers should be positioned symmetrically and at an equal distance from the listening position. If the frequency balance is not quite right, try moving the subwoofer to the left or right along the wall so that different room modes are excited at different levels. Positioning the subwoofer close to a corner will boost the bass level at lower frequencies and may cause asymmetrical spatial imaging.
ISSTM Autostart
The automatic power saving function ISS (Intelligent Signal Sensing) can be
activated by setting the “ISS” switch on the connector panel to “ON.”
Automatic powering down to standby mode happens after a certain time when
playback has ended. The power consumption in standby mode is typically less
than 0.5 watts. Playback will automatically resume once an input signal is
detected from any source. Alternatively, the subwoofer can be activated by
pushing any button on the remote control. There is a slight delay in the
automatic powering up. If this is undesirable, the ISSTM function can be
disabled by setting the “ISS” switch on the connector panel to “OFF.” In this
mode, the subwoofer is powered on and off using the remote control or the
power button on the connector panel. The “ISS SENSITIVITY LOW” switch lowers
the triggering sensitivity of the ISS function. This can be necessary if the
subwoofer “wakes up” even if there is no audio signal.
Setting The Playback Level
The rotary “SUBWOOFER LEVEL” level adjustment can be used to match the
subwoofer’s playback level with the main loudspeakers.
Setting The Bass Roll-Off Switches
The acoustic response of the subwoofer may have to be matched to the
characteristics of the room and the positioning in which it will be used (see
Table 1). To adjust the subwoofer to match these characteristics use the
‘’BASS ROLL-OFF’ control switches located on the connector panel. When all
Roll-Off switches are ‘OFF’, a flat anechoic response is obtained.
Setting The Phase Control
The effect of incorrect phase alignment between the main loudspeakers and the
subwoofer is a drop in the frequency response of the whole system at the main
loudspeaker/subwoofer crossover frequency. The phase difference between the
main loudspeakers and subwoofer at the listening position is dependent upon
the distance from the listener to the subwoofer in relation to the main
loudspeakers. To avoid phase differences between the left and right main
loudspeakers and the subwoofer, the subwoofer should be placed close to the
center of the front loud-speaker array. Two-phase matching switches allow
compensation for incorrect phase alignment. Four settings are provided between
0° and -270°.
Coarse Phase Correction Method
Connect an audio frequency signal generator to a signal input on the subwoofer
which has a main loudspeaker connected to the corresponding “OUT” connector.
If the loudspeakers are placed at different distances from the listening
position, choose the loudspeaker that is nearer. Set the generator to 85 Hz.
If a signal generator is not available, it is possible to use an audio test
recording which has a test frequency in the range 70 Hz to 100 Hz. Suitable
test signals can be downloaded at www.genelec.com and found in some
smartphones.
- Toggle the -180° phase switch ‘ON’ and ‘OFF’ and set it to the position which gives the lowest sound level at the listening position.
- Next toggle the -90°phase switch ‘ON’ and ‘OFF’, and again set it to the position which gives the lowest sound level.
- Finally, set the -180°phase switch to the opposite setting.
Matching IR Remote Controls
The F One subwoofer can be used with most IR remote controls, providing
convenient use with, for instance, the remote control of a TV set when
connected to it via a fixed-level digital signal input. Turn the subwoofer
upside down so you can easily reach the “Select” button on the subwoofer’s
connector and the status indicator LED on the subwoofer’s foot is visible. The
IR receiver is located in the LED. Note that the “Select” buttons on the RF
remote control provided with the subwoofer do not actuate the matching.
The matching procedure is as follows:
- Keep the “Select” button on the subwoofer depressed until the status indicator LED starts blinking red.
- Choose the button on the remote control that you want to actuate “volume up” function. Keep it depressed until the LED stops blinking. With some remote controls pressing the button multiple times works better.
- Now the LED blinks green, indicating that the button for “volume down” can be selected. Follow the procedure described above.
- Next the LED blinks blue for selection of the button for “Select” button.
- Yellow LED indicates the selection of “Mute” button.
- Magenta LED indicates the selection of “Power” button.
A short press on the “Select” button allows you to skip a step in the procedure, if you do not want to “teach” all the commands listed above. If you want to interrupt the procedure, press “Select” for approximately two seconds. This saves the settings made so far. If you don’t want to save the settings, press the Power button for two seconds. This will also delete the matching settings done by that point. If you want to change the matched buttons, just redo the matching process.
Matching The RF Remote Control To The Subwoofer
When shipped, the remote controls delivered with F One subwoofers will
function with any other F One subwoofer as well. If this is not desirable, for
instance when there are several F One subwoofers in the same premises, and the
user wishes to avoid the situation where more than one subwoofer reacts to the
commands given by each remote control, the remote controls can be matched to
operate only one subwoofer.
- Press and hold down the “Power” and “Select “ buttons on the subwoofer until the LED starts blinking white.
- While the LED is blinking, first press and hold down the volume “+“ button on the remote control and then the volume “-“ button. Keep both buttons pressed for a few seconds until the status indicator LED on the subwoofer stops blinking. This indicates that matching is completed and the matching operation ends automatically.
Now the subwoofer should only respond to commands given by the matched remote
control, and respectively, the matched remote control should not work with
other F Two units. For canceling the matching operation while the LED is
blinking, press and hold down the ”Power” button on the subwoofer for two
seconds. If you wish to undo a matching completely, press and hold down the
”Power” button on the subwoofer for ten seconds.
NOTE: In some cases the local WiFi network can cause problems with the RF
remote control, if they operate on the same wavelength. We recommend the use
of an IR remote control in these cases.
Safety Considerations
The Genelec F One complies with international safety standards. However, to ensure safe operation and maintain the equipment in safe operating condition the following warnings and cautions must be observed.
-
• Do not use this product with an unearthed mains cable or a mains connection without the protective earth contact as this may lead to personal injury.
• Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type. -
• The battery shall not be exposed to excessive heat such as sunshine, fire or the like.
• Servicing and adjustment must only be performed by qualified service personnel.
• Opening the subwoofer is strictly prohibited except by qualified service personnel. -
• The battery shall not be exposed to excessive heat such as sunshine, fire or the like.
• Servicing and adjustment must only be performed by qualified service personnel.
• Opening the subwoofer is strictly prohibited except by qualified service personnel.
Note that the amplifier is not completely disconnected from the AC mains
service unless the mains cable is removed from the amplifier or the mains
outlet.
Warning! This equipment is capable of delivering sound pressure levels in
excess of 85 dB, which may cause permanent hearing damage.
Compliance To FCC Rules
Remote control
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation. This product emits radio frequency energy, but the
radiated output power of this device is below FCC radio frequency exposure
limits. This equipment complies with FCC RF radiation exposure limits forth
for an uncontrolled environment. Nevertheless, the device should be used in
such a manner that the potential for human con-tact with the antenna during
normal operation is minimized. Changes or modifications not expressly approved
by the party responsible for compliance could void the user’s authority to
operate the equipment.
Subwoofer
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
This device may not cause harmful interference, and this device must accept
any interference received, including interference that may cause undesired
operation.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment under FCC rules.
Changing The Remote Control Battery
The remote control battery can be changed by turning the battery cover on the back of the remote control anticlockwise. Use a small screwdriver under the right side of the battery (see figure 5) to wedge the battery out. Replace the battery with a similar CR2032 type battery. Insert the battery with the left side first as shown in figure 5 and close the battery cover. Take the used battery to your local battery recycling point. Under no circumstances should the battery be disposed with general dry waste.
Maintenance
There are no user-serviceable parts inside the subwoofer. Any maintenance of
the unit must only be performed by qualified service personnel.
Guarantee
This product is supplied with two year guarantee against manufacturing faults
or defects that might alter the performance of the unit. By registering your
product at: www.community.genelec.com
You can get an additional three-year guarantee that covers the spare parts.
SPECIFICATIONS
SYSTEM SPECIFICATIONS
F One | |
---|---|
Free field frequency response (-6 dB) | Main 35 Hz…85 Hz LFE 35 Hz…120 Hz |
Maximum short term sine wave SPL output averaged from 30 to 85 Hz, measured in
half space at 1 meter| 100 dB
Self generated noise level in half space at 1 m on axis (A-weighted)| ≤ 5 dB
SPL
Driver, magnetically shielded| 165 mm (6 1/2 in)
Weight| 5.6 kg (12.3 lb)
Dimensions
Height Diameter
|
256 mm (97/8”)
305 mm (12”)
AMPLIFIER SECTION
F One |
---|
Amplifier short term output power
(Long term output power is limited by driver unit protection circuitry)
| 40 W
Amplifier system THD at nominal output| ≤ 0.05 %
Mains voltage| 100 – 240 VAC 50/60 Hz
Power consumption (average)|
Stand by| 0.5 W
Idle| 5 W
Full output| 60 W
CONNECTORS
F One |
---|
Amplifier short term output power
(Long term output power is limited by driver unit protection circuitry)
| 40 W
Amplifier system THD at nominal output| ≤ 0.05 %
Mains voltage| 100 – 240 VAC 50/60 Hz
Power consumption (average)|
Stand by| 0.5 W
Idle| 5 W
Full output| 60 W
CROSSOVER SECTION
F One | |
---|---|
Subsonic filter (18 dB/octave) below | 35 Hz |
Crossover frequency (subwoofer/main channels) | 85 Hz |
LFE channel cutoff frequency | 120 Hz |
Midband rejection >400 Hz | > 50 dB |
Analog input level for 90 dB SPL output at 1 m | -8 dBu at level control max |
Digital input level for 90 dB SPL output at 1 m | -19dBFS at level control max |
Digital input word length | 16…24 bits |
Digital input sample rate | 32…96 kHz |
Sensitivity adjustment range | 18 dB |
Bass Roll-Off control operating range in 2 dB steps | From 0 to -6 dB @ 35 Hz |
Phase matching control in 90° steps | From 0 to -270° @ 85 Hz |
Genelec Document D0163R001. Copyright Genelec Oy 5.2019. All data subject to change without prior notice
International enquiries: Genelec, Olvitie 5 FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email genelec@genelec.com
In the U.S. please contact: Genelec Inc., 7 Tech Circle Natick, MA 01760,
U.S.A.
Phone +1 508 652 0900
Fax +1 508 652 0909
Email genelec.usa@genelec.com
In China please contact: Beijing Genelec Audio Co. Ltd. Jianwai SOHO,
Tower 12, Room 2605 39 East 3rd Ring Road, Chaoyang District Beijing 100022,
China
Phone +86 10 5869 7915
Fax +86 10 5869 7914
In Sweden please contact Genelec Sverige Ellipsvägen 10B
P.O. Box 5521, S-141 05 Huddinge
Phone +46 8 449 5220
Fax +46 8 708 7071
Email info@genelec.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>