AEG AXP34U338CW Air Conditioner User Manual
- June 13, 2024
- AEG
Table of Contents
- CUSTOMER CARE AND SERVICE
- ****SAFETY INFORMATION
- SAFETY INSTRUCTION
- UNIT DESCRIPTION
- ACCESSORIES INCLUDED
- INSTALLATION INSTRUCTIONS
- AIR CONDITIONER FEATURES
- OPERATING INSTRUCTIONS
- TROUBLE SHOOTING
- ENVIRONMENTAL CONCERNS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AEG AXP34U338CW Air Conditioner User Manual
FOR PERFECT RESULTS
Thank you for choosing this AEG product. We have created it to give you
impeccable performance for many years, with innovative technologies that help
make life simpler – features you might not find on ordinary appliances. Please
spend a few minutes reading to get the very best from it.
Visit our website for:
Get usage advice, brochures,
trouble shooter, service information: www.aeg.com
Register your product for better
service: www.registeraeg.com
Buy Accessories, Consumables and
Original spare parts for your
appliance:www.aeg.com/shop
CUSTOMER CARE AND SERVICE
Always use original spare parts.
When contacting our Authorized Service Centre, ensure that you have the
following data available: Model, PNC, Serial Number.
The information can be found on the rating plate.
Warning / Caution-Safety information.
****General information and tips.
Environmental information.
Subject to change without notice.
****SAFETY INFORMATION
Symbol | Note | Explanation |
---|---|---|
WARNING | This symbol shows that this appliance uses a flammable |
refrigerant. If the refrigerant is leaked and exposed to an external ignition
source, there is a risk of fire.
| CAUTION| This symbol shows that the operation manual should be read
carefully.
| CAUTION| This symbol shows that a service personnel should be handling
this equipment with reference to the installation manual.
| CAUTION| This symbol shows that information is available such as the
operating manual or installation manual.
WARNING!
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Children shall not play with the appliance.
- If the supply cord is damaged, it must bereplaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
This manual explains the proper use of your new air conditioner. Please read
this manual carefully beforeusing the product. This manual should be kept in a
safe place for handy reference.
CAUTION!
- Contact authorised service technician for repair or maintenance of this unit.
- Contact the installer for installation of this unit.
- The air conditioner is not intended for use by young children of infirmed persons without supervision.
- Young children should be supervised to ensure that they do not play with the air conditioner.
- There are local council rules regarding maximum allowable noise levels emitted by air conditioners.
- If the power cord is to be replaced, replacement work shall be performed by authorised personnel only.
- Installation work must be performed in accordance with the national wiring standards by authorised personnel only (if applicable). Incorrect connection can cause overheating and fire.
- Take care not to catch fingers on fan when adjusting horizontal louvres.
- The fuse is 250V 3.15A, ceramic type.
- Cleaning and user maintenance shall not be made by children without supervision. Be aware that refrigerants may not contain an odour.
Important notes
- Do not operate unit without the air filter.
- Do not operate unit near any heat source or open fire.
- Do not expose the unit outside to direct sunlight and rain.
- Always store or move the unit in an upright position.
- Do not cover the appliance when in operation or immediately after use.
- Always drain condensation before storing unit.
Point to Keep in Mind When Using Your Air Conditioner
CAUTION!
Warnings for use
- Do not modify any part of this product.
- Do not insert anything into any part of the unit.
- Ensure the power supply used has an appropriate voltage rating. Only use a 220 – 240V, 50Hz, 10A mains electricity supply. Use of a power supply with an improper voltage rating can result in damage to the unit an possibly fire.
- Always use a anti-explosive circuit breaker or fuse with the proper amp rating. Do not, under any circumstances, use wire, pins or other objects in place of a proper fuse.
- In the event of any abnormality with the air conditioner (eg. a burning smell), do not pull out the plug directly, open the window for ventilation firstly, then turn the unit off and disconnect the power supply.
CAUTION!
Warning for power supply cord
- This power plug must only be plugged into an appropriate wall socket. Do not use in conjunction with any extension cords.
- Push the power plug securely into the socket and make sure it is not loose.
- Do not pull, deform. or modify the power supply cord, or immerse it in water. Pulling or misuse of the power supply cord can result in damage to the unit and cause electrical shock.
- If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Use only the manufacturer specified power cord for replacement.
- This appliance must be earthed. This appliance is equipped with a cord having an earth wire.
The plug must be plugged into an outlet that is properly installed and earthed. Do not under any circumstances cut or remove the square earthed pin (only for UK) from this plug.
(only for UK)
Usage cautions
-
Be sure to turn the unit off and disconnect the power supply cord before performing any maintenance or cleaning.
-
Do not put unit near any heat source or open fire when you replacing the filters.
-
Do not splash or pour water directly onto the unit.
Water can cause electrical shock or equipment damage. -
Drainage should be performed whenever moving the air conditioner. If any water remains in the tank, it may spill out while being moved.
-
To ensure proper drainage, the drainage hose must have no kinks and must not be elevated during dehumidificatioin mode. If not, the drained water may spill out into the room.
-
The temperature around the drainage hose must not be below freezing point when used. Drained water may freeze inside the hose, causing water inside the unit to overflow into the room.
-
Do not block the exhaust air outlet with obstacles. Cooling performance may be reduced or stop completely.
-
Provide a anti-explosive residual current device (RCD) in order to protect against electric shock in accordance with British Standard and Wiring Rules.
-
Exposure to direct airflow for an extended period of time could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
-
Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices, food, pets, plants, and art objects). Usage in such a manner could harm such property.
-
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
-
The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
-
Do not pierce or burn.
-
Compliance with national gas regulations shall be observed.
-
Keep ventilation openings clear of obstruction.
-
The appliance shall be stored in a well-ventilated area where the room size larger than 12 m2 .
PLEASE NOTE: CHECK THE PLATE FOR THE TYPE OF REFRIGERANT GAS USED IN YOUR APPLIANCE.
WARNING!
Specific information regarding appliances with R290 refrigerant gas.
- Thoroughly read all of the warnings.
- When defrosting and cleaning the appliance, do not use any tools other than those recommended by the manufacturing company.
- The appliance must be placed in an area without any continuous sources of ignition (for example: open flames, gas or electrical appliances in operation).
- Do not puncture and do not burn.
- Refrigerant gases can be odorless.
- The appliance must be installed, used and stored in an area that is greater than 12 m2.
- This appliance contains a certain number of grams (see rating label back of unit) of R290 refrigerant gas.
- R290 is a refrigerant gas that complies with the European directives on the environment. Do not puncture any part of the refrigerant circuit.
- If the appliance is installed, operated or stored in a nonventilated area, the room must be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric heaters, stoves, or other sources of ignition.
- The appliance must be stored in such a way as to prevent mechanical failure.
- Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued by an accredited or generation that ensures competence in handling refrigerants according to a specific evaluation recognized by associations in the industry.
- Repairs must be performed based on the recommendations from the manufacturing company.
Maintenance and repairs that require the assistance of other qualified personnel must be performed under the supervision of an individual specified in the use of flammable refrigerants.
Additional information
Transport of equipment containing flammable refrigerants
See transport regulations.
Marking of equipment using signs
See local regulations.
Disposal of equipment using flammable refrigerants
See national regulations.
Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer’s
instructions.
Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical damage
to the equipment inside the package will not cause a leak of the refrigerant
charge. The maximum number of pieces of equipment permitted to be stored
together will be determined by local regulations.
SAFETY INSTRUCTION
Notes on Operation
-
Allow 4 minutes for the compressor to restart cooling. If you turn the air conditioner off and immediately restart it, allow 4 minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor turned off for 4 minutes for safety.
-
In the event of a power failure during use, allow 4 minutes before restarting the unit. After power is reinstated, restart the air conditioner. If the power was off for less than four minutes, be sure to wait at least four minutes before restarting the unit. if you restart the air conditioner within four minutes, a protective device in the unit may cause the compressor to shut off. This protective device will prevent cooling for about 5 minutes. Any previous setting will be cancelled and the unit will return to its initial setting.
-
When you turn the unit off in cooling mode, the compressor will shut off immediately and the upper/under fan motor will stop running after 5 seconds;
if operate the unit to fan mode from cooling mode, the compressor will shut off immediately and the under fan motor will stop running after 5 seconds; and if operate the unit to heating mode from cooling mode, the compressor will shut off immediately and the under fan motor will stop running after 30 seconds. -
Low temperature operation: Is your unit freezing up? Freezing may occur when the unit is set close to 18°C in low ambient temperature conditions, especially at night. In these conditions, a further temperature drop may cause the unit to freeze. Setting the unit to a higher temperature will prevent it from freezing.
-
Dehumidification mode increases room temperature. The unit generates heat during dehumidification mode and the room temperature will rise. Warm air will be blown out from the exhaust air outlet, but this is normal and does not indicate a problem with the unit.
-
This air conditioner blows the warm air generated by the unit outside the room via the exhaust hose while in cool mode. In the mean time, the same amount of air will enter the room from outsidethrough any openings of the room.
-
Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification.
-
Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
-
The working temperature range of the air conditioner is 16-35oC (60-95o F) under cooling mode; 5-27oC (41-80o F)
under heating mode.
To prevent injury to the user or other people and property damage, the
following instructions must be followed.
Incorrect operation due to ignoring instructions may cause harm or damage.
The seriousness is classified by the following indications:
WARNING!
This symbol indicates the possibility of death or serious injury.
CAUTION!
This symbol indicates the possibility of injury or damage to property.
Meanings of symbols used in this manual are shown below:
This symbol indicates never to do this.
This symbol indicates always do this.
Warning during usage
WARNING!
Warning during usage
Warning
|
Meaning
---|---
Plug in power plug properly| Otherwise, it may cause electric shock, fire and
explosion due to excess heat generation
Do not operate or stop the unit by inserting or pulling out Die power plug| It
may cause electric shock, fire and
explosion due to heat generation
Do not damage or use an unspecified power cord| It may cause electric shock,
fire and explosion. If the power cord is damaged, it must be replaced by the
manufacturer or an authorised service centre or a similarly qualified person
in order to avoid a hazard
Do not modify power cord length or share the outlet with other appliances| It
may cause electric shock, fire and
explosion due to heat generation
Do not operate with wet hands or in damp environment| It may cause electric
shock
Do not direct airflow at room occupants| This could harm your health
Always ensure effective earthing| Incorrect earthing may cause electric shock
Do not allow water to run into electric parts| It may cause failure of unit or
electric shock
Always install circuit breaker and a dedicated power circuit| Incorrect
installation may cause electric
shock, fire and explosion
Unplug the unit if strange sounds, smell, or smoke comes from it| It may cause electric shock, fire and
explosion
Do not use the socket if it is loose or damaged| It may cause electric shock, fire and
explosion
Do not open the unit during operation| It may cause electric shock, fire and
explosion
Keep firearms away| It may cause fire and explosion
Do not use the power cord close to heating appliances| It may cause electric
shock, fire and
explosion
Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc.| It may cause electric shock, fire and
explosion
Ventilate room before operating air conditioner if there is a gas leakage from another appliance| It may cause explosion, fire, explosion and
burns
Do not disassemble or modify unit| It may cause failure and electric shock
Caution
|
Meaning
When the air filter is to be removed, do not
touch the metal parts of the unit
| It may cause an injury
Do not clean the air conditioner with water| Water may enter the unit and
degrade the insulation. It may cause an electric shock
Ventilate the room well when used together with a stove, etc.| An oxygen
shortage may occur
When the unit is to be cleaned, switch off, and turn off the circuit breaker|
Do not clean unit when power is on as it may cause fire, explosion and
electric shock, it may cause an injury
Do not place a pet or house plant where it
will be exposed to direct air flow
| This could injure the pet or plant
Do not use for special purposes| Do not use this air conditioner to preserve
precision devices, food, pets, plants, and art objects. It may cause
deterioration of quality, etc.
Stop operation and close the window in storm or cyclone| Operation with
windows opened may cause wetting of indoor and soaking of household furniture
Hold the plug by the head of the power plug when taking it out| It may cause
electric shock and damage
Turn off the main power switch when not
using the unit for a long time
| It may cause failure of product or fire and
explosion
Do not place obstacles around air-inlets or inside of air-outlet| It may cause
failure of appliance or accident
Always insert the filters securely. Clean filter
once every two weeks
| Operation without filters may cause failure
Do not use strong detergent such as wax or thinner – use a soft cloth|
Appearance may be deteriorated due to change of product colour or scratching
of its surface
Do not place heavy object on the power cord and ensure that the cord is not
compressed| There is danger of fire, explosion or electric
shock
Caution| Meaning
Do not drink water drained from air conditioner| It contains contaminants and
could make you sick
Use caution when unpacking and installing| Sharp edges could cause injury
If water enters the unit, turn the unit off at the power outlet and switch off
the circuit breaker. Isolate supply by taking the power- plug out and contact
a qualified service technician| It could cause electric shock and damage
UNIT DESCRIPTION
- Remote control
- Signal receiver
- Room air outlet
- Control panel
- Carrying handle (both sides)
- Air intake
- Continuous drain outlet
- Pump drain outlet
- Bottom drain outlet
- Air exhaust
- Power plug socket
- Power cord
- Castor
ACCESSORIES INCLUDED
PARTS | PARTS NAME: | QUANTITY: |
---|---|---|
1 | Adaptor A, Exhaust |
duct,Adaptor B (flat mouth),| 1 set
2| Drain hose
| 1 pc
3| Remote control
| 1 set
4| Battery (R03P “AAA” 1.5V)
| 2 pcs
INSTALLATION INSTRUCTIONS
Exhausting hot air
In the Cool Mode the appliance must be placed close to a window or opening
so that the warm exhaust air can be ducted outside. First position unit on a
flat floor and make sure there’s a minimum of 50cm clearance around the unit,
and is within the vicinity of a single circuit outlet power source.
-
Extend either side of the hose (Fig. 1)
and screw the hose to adaptor A (Fig. 2).
The adaptor A already be screwed to the hose for this unit. -
Extend the other side of the hose and screw it to adaptor B (Fig. 3).
-
Install the adaptor A into the unit (Fig. 4).
-
Affix the adaptor B into the window. (Fig. 5)
The hose can be extended from its original length of 38cm up to 150cm, but it is the best to keep the length to minimum required.
Also make sure that the hose does not have any sharp bends or sags. (Fig. 6)
AIR CONDITIONER FEATURES
CONTROL PANEL
- Displays temperature/time
- Power ON/OFF
- Filter Reset
- Fan Speed
- Adjust Temperature or Timer
- Mode Selection
- Sleep
- Timer
- Swing
OPERATING INSTRUCTIONS
Some of the following instructions can only be used by using the Control Panel.
Usage of the Control Panel
Heating mode (on some models)
In this mode the exhaust adaptor hose MUST be used.
- Press the “fan speed” button tochoose the fan speed according to the illumination of the fan speed indicator. You can choose the fan speed as following sequence: “auto” → “hi” → “med” → “low” → “auto”.
- Press the “ ” or “ ” button to choose the temperature you want.
- Connected drain hose. See 7.4 Drainage section.
Cooling mode
In this mode the exhaust adaptor hose MUST be used.
- Press the “mode” button until the Cool mode indicator is lit.
- Press the “fan speed” button to choose the fan speed according to the illumination of the fan speed indicator. You can choose the fan speed as following sequence: “auto” → “hi” → “med” → “low” → “auto”.
- Press the “ ” or “ ” button to choose the temperature you want.
It is not necessary to use thedrainage hose in the “cool” mode.
Dry mode
Press the “mode” button until the Dry mode indicator is lit. The screen
displays the room temperature.
At the same time, the “low” fan indicator lights.
Note: In this mode, fan speed cannot be selected.
Fan mode
In this mode, there is no need to use the exhaust hose or drainage hose.
- Press the “mode” button until the Fan mode indicator is lit.
- Press the “Fan speed” button to choose the desired fan speed.
- The fan will run at the selected speed and the display will show the room temperature.
Note: In this mode, auto speed cannot be selected.
Auto mode
Always have the exhaust hose attached in this mode.
When you set the air conditionerin Auto mode, it will automatically select
cooling, heating (inapplicable for cooling only models), or fan only operation
depending on what temperature you have selected and the room temperature. The
air conditioner will control room temperature automatically round the
temperature point set by you.
Under AUTO mode, you can not selectthe fan speed.
- Press the “mode” button until the “Auto mode” indicator lights.
After the “Auto mode” is selected the unit will run automatically according to the actual room air temperature.
Timer mode
The timer facilitates the user to delay the unit startup or shutdown.
How to delay startup
Plug in the unit, so the unit turns to standby.
Press the “timer” button, then the Timer indicator will switch on and the
number of hours on the screen will show “0.0”.
Tap or hold the UP arrow “ ” or the DOWN arrow “ ” to change delay start timer
at 0.5 hour increments up to 10 hours, then at 1 hour increments up to 24
hours. Press the “timer” button again within 5 seconds, you will quit the
timer setting directly. After 5 seconds, the timer function is enabled, the
display will show the temperature back. The control will count down the time
remaining until startup. The unit will start up in the mode as previously set.
To cancel the setting, press the “timer” button again will show the remain
time. and press the button again to quit the function. You can also cancel the
setting by pressing the “on/off” button. After cancel the setting, the timer
indicator will switch off.
How to delay shutdown
You can delay shutdown when the unit is on.
Press the “timer” button, then the Timer indicator will switch on and the
number of hours on the screen will show “0.0”.
Tap or hold the UP arrow “ ” or the DOWN arrow “ ” to change delay stop timer
at 0.5 hour increments up to 10 hours, then at 1 hour increments up to 24
hours. Press the “timer” button again within 5 seconds, you will quit the
timer setting directly.
After 5 seconds, the timer function is enabled, the display will show the
temperature back. The control will count down the time remaining until shuts
down.
To cancel the setting, press the “timer” button again will show the remaing
time and press the button again to quit the function. You can also cancel the
setting by pressing the “on/off” button. After cancel the setting, the timer
indicator will switch off.
Sleep mode
Active this feature will give you a comfortable temperature and help save
energy.
Only when the unit is in Cool, Heat or auto mode, you can press the “sleep”
button to make the unit run in Sleep mode.
Note: Please refer to page 17 for the details about “Sleep” mode.
Louver Swing Function
Press the “swing” button to enable louver swing function, the louver on the top panel will swing up and down. Press this button again to disable the louver swing function.
°F/°C function
Press the “ _ ” and “ + ” button the same time for more than 3 seconds to switch between degree Fahrenheit and degrees Celsius. Under Dry/Fan mode, you can not select °F/°C.
Filter reset
This feature is a reminder to clean the Air Filter (See Care and Cleaning) for
more efficient operation.
The filter indicator will illuminate after 250 hours of operation. To reset
after cleaning the filter, press the “filter reset” button, then the “filter”
indicator will go off.
Remote Control
- Remote Control screen
- Temp/Timer setting button
- Mode button
- Timer button
- On/Off button
- Speed button
- Sleep button
- Swing button
Battery Installation and Important Instructions
Remove the cover at the back of the remote control.
Insert the provided batteries correctly (see the instructions inside the
battery compartment).
Close up the cover.
To replace the old batteries (which have been used up) with two new R03P “AAA”
1.5V batteries, repeat the steps above.
If the remote control unit is replaced or discarded, the batteries must be
removed and disposed of in accordance with local legislation as they do harm
to the environment.
Do not mix old and new batteries.
Do not mix alkaline, standard (carbonzinc) or rechargeable (nickel-cadmium)
batteries.
Do not dispose of batteries in fire. Batteries may explode or leak. If the
remote control is not used for a long time, remove the batteries from the
remote control.
The remote control must be handled with extreme care. Do not drop it or expose
it to direct sunlight or sources of heat.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
Point the remote control at the location of the signal receiver. The remote
control must be no more than 16 ft (5 meters) away from the unit (without
obstacles between the remote control and the unit).
How to Use the Remote Control
TURNING THE UNIT ON
Plug in the unit, then press the “on/off” button (when turned on, the unit
will operate as the last setting before shutdown.
To switch the unit off, press “on/off” button again, then remove the plug.
Always switch the unit off by pressing the “on/off” button and wait for few
minutes before removing the plug.
Cool mode
Press the “mode” button until the left side of LCD screen displays “cool”.
Press the “fan speed” button to choose the fan speed“auto”, “high”, “mid”,
and“low”. Press the “ _ ” and “ +” button to choose the temperature you
want.
Dry mode
Press the “mode” button until the left side of LCD screen displays “dry”. At
the same time, the “low” fan symbol
appears on the screen.
Note: In this mode, fan speed cannot be selected.
Fan mode
Press the “mode” button until the left side of LCD screen displays “fan”. In
this mode, you can select fan speed “high”, “mid” or “low” by pressing the
Fan speed button and referring to the diagram.
Note: In this mode, the air exhaust hose does not need to be connected.
Heat mode (For Heat & Cool models only)
Press the “mode” button until the left side of LCD screen displays “heat”.
Press the “fan speed” button to choose the fan speed “auto”, “high”, “mid”,
and“ low”. Press the “_ ” and “+ ” button to choose the temperature you want.
AUTO mode
Press the “mode” button until the upper side of LCD screen displays “auto”.
Under AUTO mode, you can not select the fan speed.
Press the “_” and “ +” button to choose the temperature you want.
Sleep mode
When the unit is in Cool, Heat or auto mode, you can press the “sleep” button
to make the unit run in Sleep mode. In this mode, the fan speed will be set as
“auto” automatically, which cannot be changed.
In Cool/Heat mode the selected temperature will increase/decrease by 1°C 30
minutes after the mode is selected. The temperature will then
increase/decrease by another 1°C after an additional 30 minutes. This new
temperature will be maintained for 7 hours before it returns to the originally
selected temperature. This ends the “Sleep” mode and the unit will shut down
automatically.
The “Sleep” mode program can be cancelled at any time during operation by
pressing the “Sleep”, “mode” or “fan speed” button.
Note: In Fan or Dry mode, Sleep mode cannot be set.
Louver Swing Function
Press the “swing” button to enable louver swing function, and the upper side
of screen will display “swing* ”. The louver on the top panel will swing up
and down.
Press this button again to disable the louver swing function.
°F/°C function
Press the “_ ” and “ +” button the same time for more than 3 seconds to switch between degree Fahrenheit and degrees Celsius. Under Dry/Fan mode, you can not select °F/°C.
Timer mode
How to delay startup
Plug in the unit, so the unit turns to standby. Press the “timer” button, the
screen will display “timer”and “h”, and the “on” will flashing.
Tap or hold the UP arrow “ ” or the DOWN arrow “ ” to change delay start timer
at 0.5 hour increments up to 10 hours, then at 1 hour increments up to 24
hours. After 3 seconds, the setting will be memorized. The control will count
down the time remaining until startup.
You can also press the “timer” button again directly and the “on” will stop
flashing immediately, then the unit will start up in the mode as previously
set.
You can set up the mode and the unit will start up as you preferred after “on”
stop flashing.
To cancel the setting, press the “timer” button again.
How to delay shutdown
You can delay shutdown when the unit is on. Press the “timer” button, the
screen will display “timer”and “h”, and the “off” will flashing.
Tap or hold the UP arrow “ ” or the DOWN arrow “ ” to change delay stop timer
at 0.5 hour increments up to 10 hours, then at 1 hour increments up to 24
hours. After 3 seconds, the setting will be memorized, and the display will
show the time remaining until the unit shuts down.You can also press the
“timer” button again directly and the “off” will stop flashing immediately.
To cancel the setting, press the “timer” button again.
Fault code
If the display reads “AS”, “CS” and “ES”, the temperature sensor has failed. Contact your Authorized AEG Service Center.
If the display reads “L3”, the condenser DC fan motor has failed. Contact your Authorized AEG Service Center.
If the display reads “P1”, bottom tray is full. Carefully move the unit to a drain location, remove the bottom drain plug and let the water drain away. Restart the machine until the “P1” symbol disappears. If error repeats, call for service.
If the display reads “E4”, the communication between display PCB and main control PCB is faulty. Contact your Authorized AEG Service Center.
Drainage instruction
Continuous Drainage
During the DRY mode or heat pump model, you will need a garden hose (sold separately) or drain hose to drain the condensate from the unit. Follow the steps below
-
Unscrew the drain cap of continuous drain outlet (Fig.20).
-
Connect one end of the garden hose (sold separately) or drain hose to the drain outlet then lead the other end into a drain that is lower than the unit( Fig.21).
NOTE:
- Condensate may flow out after removing the drain cap, if the unit is running in Cool or Auto mode. When you want to remove the garden hose, prepare a drip tray (not supplied) to collect the condensate from the drain outlet.
- Please be sure that the height of the drain and section of the drain hose should not be higher than that of the drain outlet, or the continous drainage may not work properly.
- During Cool or Auto mode, it is recommended to disable continuous drainage by replacing the drain cap to the drain outlet, to reach the maximum performance.
Emptying the condensate residue inside the unit during winter storage.
Put a drip tray (not supplied) under bottom drain outlet, then pull out the
drain cap to allow the condensate to flow into the drip tray.
Replace the drain cap to the continuous drain outlet when no condensate flows
out.
Put the drip tray under the bottom drain outlet, then remove the rubber
stopper from the drain outlet, to allow the condensate to flow into the drip
tray. If your drip tray can’t hold all the condensate, a number of fills will
be needed.
Replace the drain cap to the bottom drain outlet when no condensate flows out.
NOTE: To ensure all condensate residue has been removed, tilt the unit by lifting it slightly upwards from the front until no more condensate comes out from the drain outlet.
-
Removed the air filter as shown the below figure.
To keep your air conditioner working efficiently, you should clean the filters every two weeks of operation. -
Wash the filter using liquid dishwashing detergent and warm water under 40°C. Rinse filter thoroughly. Gently shake excess water from the filter. Be sure filter is thoroughly dry before replacing. Or, instead of washing you may vacuum the filter clean.
-
Replace the filter after the filter is dry.
Be sure filter is thoroughly dry before replacing.
Winter Storage
If the air conditioner will not be used for an extended period of time:
- Drain the water collection tank completely and leave the bottom drain cap and rubber plug long time enough to allow any residual water to drain out. Once the tank is completely drained and no more water flows out, reinstall the rubber plug and cap.
- Remove and clean the filter, allow it to dry completely, then reinstall it.
- Remove the batteries from the remote control.
- Store the air conditioner in a cool, dry location, away from direct sunlight, extreme temperature, excessive dust, and well ventilated.
Before using the air conditioner again:
- Make sure the filter and drain cap are in place.
- Check the cord to make sure it is in good condition, without cracks or damage.
- Place new batteries in the remote control.
- Install the air conditioner as described in the Installation Instructions.
TROUBLE SHOOTING
Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.
Air conditioner will not operate.
- Wall plug disconnected. Push plug firmly into wall outlet.
- House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.
- Control is OFF. Turn Control ON and set to desired setting.
- Fault code P1 appears in the display window. Drain water as described in
Drainage Section.
- Room Temperature lower than the set temperature (Cool Mode) or Room Temperature higher than the set temperature (Heat Mode). Reset the temperature.
Air from unit does not feel cold enough.
- Room temperature below 16°C. Cooling may not occur until room temperature rises above 16°C.
- Reset to a lower temperature.
- Compressor shut-off by changing modes. Wait approximately 4 minutes and listen for compressor to restart when set in the COOL mode.
Air conditioner cooling, but room is too warm – NO ice forming on cooling coil behind decorative front.
-
Outdoor temperature below 16°C.
To defrost the coil, set Fan mode. -
Air filter may be dirty. Clean filter.
Refer to 8. Care and Cleaning section.
To defrost, set to Fan mode. -
Temperature is set too low for nighttime cooling. To defrost the coil, set to Fan mode. Then, set temperature to a higher setting.
-
Exhaust duct not connected or blocked. See 5.1 Exhausting hot air Section.
-
Air conditioner cooling, but room is too warm – ice forming on cooling coil behind decorative front. Air conditioner turns on and off rapidly.
-
Dirty air filter – air restricted. Clean air filter. Refer to 8. Care and Cleaning section.
-
Temperature is set too high. Set temperature to a lower setting.
-
Air directional louvers positioned improperly. Position louvers for better air distribution.
-
Front of unit is blocked by drapes, blinds, furniture, etc. – restricts air distribution.
Clear blockage in front of unit. -
Doors, windows, registers, etc. open – cool air escapes. Close doors, windows, registers, etc.
-
Unit recently turned on in hot room. Allow additional time to remove “stored heat” from walls, ceiling, floor and furniture.
Air conditioner turns on and off rapidly.
- Dirty air filter – air restricted. Clean air filter.
- Outside temperature extremely hot. Set FAN speed to a faster setting to bring air through cooling coils more frequently.
Room too cold.
- Set temperature too low. Increase set temperature.
ENVIRONMENTAL CONCERNS
Recycle the materials with the symbol.
Put the packaging in applicable containers to recycle it. Help protect the
environment and human health and to recycle waste of electrical and electronic
appliances.
Do not dispose appliances marked with the symbol with the household waste.
Return the product to your local recycling facility or contact your municipal
office.
www.aeg.com/shop
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>