GEOTAB LOGO Field Services Installer Documentation:
Rasco EPO10 + IOX-WRKS
IOX-WRKS

EPO10 IOX-WRKS Integration Cable

Notice: Always use winter input mapping for telemetries
AUX5- Belly Plow or Manual Spreader, AUX6- Front Plow, AUX7- Wing Plow, AUX8- Tow Plow or Beacon

Required Controller settings

  • Rasco EPO 10 requires protocol EN 15430-1
  • Rotate center dial to the right to obtain “Rasco” selection
  • Press “check” button, enter passcode ( 727) using the three dials, press checkmark again.
  • Select the menu button, then Executive settings, Option settings, then Mobile box.
  • Ensure baud rate is set to 115200
  • Exit to main operator screen
  • Press “test” to enter SIM mode, use up/down arrows to increase / decrease speed.
  • Confirm data flow using MyGeotab or calling support.
  • Exit SIM mode when complete.