GEOTAB 6100 GEN5 Control System Installation Guide
- June 13, 2024
- Geotab
Table of Contents
**GEOTAB 6100 GEN5 Control System Installation Guide
**
Overview
Note: Early model (GEN 4 and lower) Force America 6100’s require an ELA module. Refer to the GEN3-4 document for integration instructions for thise models.
Notice: Always use winter input mapping for telemetries AUX5- Belly Plow or Manual Spreader , AUX6- Front Plow, AUX7- Wing Plow, AUX8- Tow Plow or Beacon.
Force America 6100 configuration settings
- Once logged into the Calibration area of the 6100
Navigate to Calibration/Configuration/ Enable Options A password may be required to enter this area
- Set “Event logging serial” to “Enabled”.
- Set “Event logging (OTA)” to “Disabled”.
- Set “SIM Speed” to “Enabled”.
Navigate to Calibration/Event logging/ Intervals
- Set each parameter to “Enabled”.
Navigate to Calibration/ System Management/ Shutdown
- select “Restart now” to reboot system.
On Reboot and from the operator screen
- Set SIM speed ~ 25 MPH / KPH
- toggle (green dial) from Standby to Operations
- Verify integration
On completion
- ensure SIM speed is returned to disabled if you enabled this feature.
Interval based triggers can be changed to modify reporting frequency