Cync CFIXCNLR4S1 Full Color 4 Inch Smart LED Downlight Installation Guide
- June 13, 2024
- Cync
Table of Contents
Cync CFIXCNLR4S1 Full Color 4 Inch Smart LED Downlight
Getting Starting
-
STEP 1
Download the Cync App, powered by Savant, on your smartphone
STEP 2
Determine your Wafer Downlight location and complete installation -
STEP 3
Add your Wafer Downlight to the Cync App
*DIRECTLY CONNECT TO AMAZON ALEXA
Complete installation and turn on light..
If Alexa says, ‘New light found,” you can begin using your light with Alexa.
Otherwise say, “Alexa, discover my devices” and then use Alexa to control your
light.
For set up help, visit
cyncsupport.gelighting.com
or call 1-844-302-2943
Specification
Dimming Capability
NOT FOR USE WITH TRADITIONAL DIMMER SWITCHES. Dimmable with only CYNC and C by
GE Smart Dimmers or using the CYNC App.
BEFORE YOU BEGIN
Read these instructions completely and carefull.
WARNING
- Risk of fire or electric shock. Installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Minimum 90°C Conductors, if uncertain contact a qualified electrician.
- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
- These products are suitable far use in wet locations.
- IC roted far direct contact with insulation.
Prepare Electrical Wiring
Electrical Requirements
The LED fixture must be supplied with 120VAC 60Hz
Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance
with National Electric Code(NEC) Article 410 and local codes.
BEFORE YOU DO ANYTHING: Turn Off Power
STEP 1
Turn off power source at the main circuit breaker or fuse box.
Mark the Location on the Ceiling & Cut the Hole
STEP 2
Determine the position of your downlight. Keep in mind:
- Maximum distance from the junction box to the downlight is 16 inches.
- Location must be within range of 2.liGHz Wi-Fi to enable smart control.
- Once determined, use the hole template to trace the hole size. Cut the hole using a drywall saw or hole saw ..
4-inch wafer requires a
4-1/4 inch hole
6-inch wafer requires a
6-1/4 inch hole
Place Junction Box in the Ceiling & Install the Fixture
STEP 3
Remove the knockout using a hammer and screwdriver.
Open the junction box cover.
Attach the strain relief (not included) into the knockout hole.
Route the wires through the strain relief.
Connect the wires:
- black to black
- white to white
green to green or bare copper wire
Secure the wires with the three provided wire nuts.
Close the cover of the junction box.
Place Junction Box in the Ceiling & Install the Fixture
STEP 4
Place the junction box in the ceiling through the hole.
Connect the downlight to junction box using the connector.
Screw the connector together to complete the connection.
STEP 5
Hold the spring clips against the fixture and gently guide into the ceiling
until the clips snap into place. Turn on power source at the main circuit
breaker or fuse box.
Complete setup in the Cync App.
Additional Information and Warnings
FCC Compliance Statement Compliance Notice:
Warning: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help
The device must not be co-located or operating in conjunction with any other
antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
FCC RF Exposure Statement:
Caution: To maintain compliance with the FCC’s RF exposure guidelines,
place the product at least 20cm from nearby persons.
IC statement
This device complies with RSS2Li7 of Industry Canada. Cet appareil se conforme
a RSS2Li7 de Canada d’lndustrie.
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.
This equipment complies with IC RSS-102 radiation exposure limits set forth
for an uncontrolled environment.
This transmitter must be installed to provide a separation distance of at
least 20cm from all persons and must not be collocated or operating in
conjunction with any other antenna or transmitter.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>