INSPECT USA RHW-925 Wifi Converter Instruction Manual

June 13, 2024
INSPECT USA

INSPECT USA RHW-925 Wifi Converter

IMPORTANT INFORMATION

Your purchase of this RS232 to WiFi CONVERTER marks a step forward for you into the field of precision measurement. Although this Meter is a complex and delicate instrument, its durable structure will allow many years of use if proper operating techniques are developed. Please read the following instructions carefully and always keep this manual within easy reach.

FEATURES

  • Can be temperature and humidity data sent to the desired device through WiFi. the use of smart phones or tablet computers developed by the company’s freesoftware to do data collection record APP.

  • WiFi work mode: Access Point(AP) or Client mode

  • I/O terminal:

    1. DC 9V power input
    2. DC 9V power output(power supply for the connecting RS232 meter)
    3. Pt-1000 ohm input.
    4. Three RS232 input(photo isolate RS232 type)
      3.Ethernet RJ45 input.
  • Basic setting:
    1.NetMode, 2.SSID, 3.Password, 4.IP address, 5.Port, 6.Gateway address,

  • Simultaneous display Humidity ,Temperature,Web buie, Dew point temp. reading value.

  • Humidity range : 5% to 95%

  • Temperature range : 0 ℃ to 50 ℃, ℃/℉

  • Maximum TCP connections to 20

  • Without going through the computer settings, can be used directly after the machine settings

SPECIFICATIONS

.Gennal Specifications

Circuit Custom single-chip microprocessor LSI circuit
Display LCD Size: 3.2 X 2.4” (60 X 44.4 mm)

Dot Matrix backlit LCD (128 X 64 pixels)
Wireless| * Support IEEE 802.11b / g / n wireless standards

  • Support the range of frequency : 2.412 to 2.484 GHz.
  • Support two types of wireless networks: Access Point(AP) and Client
  • Support multiple security authentication mechanisms : 64/128/152 bit WEP encryption, WPA-PSK/ WPA2-PSK、、WPA/WPA2 security mechanism.
    NET mode setting| * Access Point (AP) Mode(Wireless)
  • Client Mode(Wireless) Ethernet Mode(RJ45)
    Measurement|
    Humidity/ Temperature
  • Dew pint Temperature
  • Wet bulb Temperature
  • Pt 1000 ohm Temp.
    Data Output USB/RS232 *Computer interface| RS232 computer serial interface
  • Connect the optional USB cable USB-01 will get the USB plug.
    *  Connect the optional RS232 cable UPCB-02 will get the RS232 plug.
    Operating temperature| 0 to 50℃ ( 32 to 122℉ ).
    Operating humidity| Less than 80% R.H..
    Power supply| AC to DC adapter 9V.
    Power

consumption

| DC 170 mA approximately.
Weight| 222 g/0.49 LB.
Dimension| 134 X 80 X 32 (5.3 X 3.1 X 1.3 inch).

  • Dimension is for the meter without antenna only.
    Accessories included| Instruction manual………………………………………………… 1PCS
      Hanging unit ( with sticker )……………………………………. 1PCS
  • AC to DC 9V power adapter………………………………….. 1PCS
    Antenna………………………………………………………………… 1PCS
    Optional Accessories| * USB cable,USB-01.
  • Data interface cable,UPCB-03.
  • Pt 1000 Temp. probe,TP-1000
  • Data Acquisition software,SW-U801-WIN,SW-U818-WIN.
  • Power interface cable, PWCB-06

Electrical Specifications (23 ± 5 ℃)

Range Resolution Accuracy
5 % to 95 %RH 0.1 %RH < 70 %RH: ± 3 %R ≧70 %RH: ±(3 %RH reading + 1 %RH)

Temperature

Range Resolution Accuracy
0.0 ℃ to 50.0 ℃ 0.1 ℃ ± 0.8 ℃
32.0 ℉ to 122.0 ℉ 0.1 ℉ ± 1.5 ℉

Dew point Temp.

Range Resolution Accuracy
-25.3 ℃ to 49.0 0.1 ℃

Humidity/Temp. Value

-13.5 ℉ to 120.0| ℉| 0.1 ℉

Wet bulb Temp.

Range Resolution Accuracy
-5.4 ℃ to 49.0 0.1 ℃

Humidity/Temp. Value

22.2 ℉ to 120.0| ℉| 0.1 ℉

Pt 1000 ohm Temperature(optional probe)

Range Resolution Accuracy
-10.0 to
14.0 to

FRONT PANEL DESCRIPTION


DC 9V Power adapter input socket
DC 9V output socket
Humidity/Temp. sensor
Antenna and antenna socket
Display
SETUP/ENTER KEY
EXIT( ) key button
▲ key button
▼ key button
 key button
key button
System reset button Stand
Hanging holes
Hanging unit ( with sticker )
Power interface cable/plugs
Isolate RS232 output socket
Pt1000 input socket
Network socket(RJ45)

MEASURING PROCEDURE

The initial startup screen

Measuring and setting screens:

  1. Measurement screen:

  2. Setting screen:

The summary description of keyboard:

  1. SETUP(Enter) KEY: Setting screen into the select key

  2. In the setting mode:
    Press ▲ or ▼ to select the field in the upper and lower beating
    ▲ or ▼ > 2 SEC.: The selected field will rapidly beating
    ▲ + ▼ > 2 SEC.: Then the entire column cleanup Press ▲ KEY hold short press ▼ KEY and the right of the text will be cleared
    KEY: Left and right keys
    EXIT/SHIFT( ) KEY: Press key text input type selection or setting screen left

  3. In the measurement mode:

In Easy mode, press ▲ + ▼ > 2 SEC. Then turned into full mode
In full mode, press ▲ + ▼ > 2 SEC. Then becomes easy mode
EXIT/SHIFT( ) KEY: Backlight control key

Setting Description:

  1. When the POWER ON, then enter the startup screen countdown 30 SEC. (SCREEN4-1-1 & SCREEN4-1-2) to 0 SEC. Then into the measurement screen (SCREEN4-2-3 or SCREEN4-2-4).
  2. Press SETUP KEY once into the setup screen as SCREEN4-2-7 or SCREEN4-2-8
  3. In the function directory option Press ▲ or ▼ KEY, functional directory option will flash.
  4. Press KEY into the content selection function directory option (in this case will flash), After selecting the complete press SETUP KEY Then back to the function directory option to determine the setting options
  5. Function directory:
    NetMode: Select AP or Client, the factory setting is Client.
    A. Enter this option, then press KEY contents into the option, then press ▲ or ▼ KEY to select AP or Client, After determining Press SETUP KEY do confirm the contents, then will return to NetMode directory
    B. Press ▼ KEY into the SSID option from NetMode
    SSID: The default setting is RHW-925
    A.
    Enter up to 21 characters
    B. Press KEY then enter the option contents, then press ▲ or ▼ KEY to select the input text, press EXIT / SHIFT KEY select words in English case or numbers. Determined by SETUP KEY do confirm the contents, then will return to the SSID directory.
    C. Press ▼ KEY into the Encrypt option from SSID
    Encrypt:The default setting is none
    A.
    none/wep_open/wep/wpa_tkip/wpa_aes/wpa2_tkip/wpa2_aes/ wpawpa2_tkip/wpawpa2_aes total of nine
    B. After pressing ▲ or ▼ KEY select the option by the need, press SETUP KEY to confirm, then will return to Encrypt directory
    C. Press ▼ KEY into the Password option from Encrypt
    Password: The default setting is 12345678
    A. Press KEY then enter the option contents, then press ▲ or ▼ KEY to select the input text, press EXIT / SHIFT KEY select English words large, lowercase and numbers Press SETUP KEY do confirm the contents, then will return to Password directory
    B. Press ▼ KEY into the IP option from Password
    IP: The default setting is 192.168.0.254
    A. Press KEY then enter the option contents, then press ▲ or ▼ KEY to select the number, press the SETUP KEY The contents do confirm, then will return to the IP directory
    B. Press ▼ KEY into the Port option from IP
    Port: The default setting is 200
    A. Input Range:1-65535
    B. Press u KEY then enter the option contents, then press ▲ or ▼ KEY to select the number, press the SETUP KEY The contents do confirm, then will return to the Port directory
    C. Press ▼ KEY into the Gateway option from Port.
    Gateway: The default setting is 192.168
    Gateway:
    The default setting is 192.168.0.1
    A. Press KEY then enter the option contents, then press ▲ or ▼ KEY to select the number, press the SETUP KEY The contents do confirm, then will return to the Gateway directory
    B.Press ▼ KEY into the Meter CH.option from Gateway
    UNIT:
    A. Press KEY once,into the UNIT Choice, then use ▲ or ▼ Key to select ℃ or ℉, then press SETUP Key back to UNIT Choice.
    B. Press▼ KEY into the Default Settings option from Meter CH.
    Default Settings: Reply factory setting (refer NO.4-7)

Set value storage:

Press EXIT / SHIFT KEY save settings, and return to the measurement screen, such as SCREEN4-2-5 or SCREEN4-2-6. This time to reconnect after about 25 SEC WiFi is doing set after, then back SCREEN4 -2-3 or SCREEN4-2-4 screen.
Measurement and WiFi connection:

A. In SCREEN4-2-1 is Temperature and Humidity measurement Function screen.
B. Pt1000 measurement Function:

  1. Pt1000 probe insert to Fig.1 3-18.
  2. In SCREEN4-2-1, press Key once ,into the Pt1000 measurement screen (as SCREE 4-2-2),then press u Key again,will back SCREE 4-2-1.
  3. SCREE 4-2-3 or SCREE 4-2-4 upper right corner Symbol flashes, that WIFI connection is ok.

Reply factory setting

  1. Press SETUP KEY once you into the setup screen as SCREEN4-2-7 & SCREEN4-2-8
  2. Press ▲、▼ KEY select the option to Default Settings item, press KEY once you enter N option, press ▲ or ▼ KEY select Y press Enter KEY ,will return to directory option then press EXIT / SHIFT KEY will return to factory default action to do its screen will SCREEN4-2-5 or SCREEN4-2-6, after about 25 SEC later. would return SCREEN4-2-3 or SCREEN4-2-4.

AP Mode:

  1. First, install lutron dedicated APP software
    The use of smart phone iOS system software download Lutron MeterApp (SCREEN4-8-1) ,iOS Password: aZ6210.
    After the download is complete, install it.

    If use of smart phone Android system software download ,please use smart phone scan the QR code provided below ,will link to Android app download file(.pdf), then Download and install according to the method shown in the file, or directly to the following URL download Lutron MeterApp. https://tinyurl.com/lutronapp
    Android Password: Az6210 Android QR Code

  2. .The RHW-925 boot into the measurement screen (SCREEN4-2-1).
    Determine the following set parameters (such as SCREEN4-2-6 )
    A.NetMode: AP
    B.SSID: RHW-925
    C.IP: 192.168.0.254
    D.Port: 200
    Start Smart Phone WiFi, make RHW-925 connection (SCREEN4-8-2).
    Open MeterApp software (such as SCREEN4-8-3)
    A. In SCREEN4-8-3 select Step1 (Meter1)
    B. Is displayed SCREEN4-8-4, select Step2 tool button then into the SCREEN4-8-5
    C. Into the relevant information in SCREEN4-8-5
    1) Meter name: Meter1 name can be changed to the desired user name
    2) CH NO.: In accordance Meter CH NO. To enter
    3) Sampling time: minutes as a reference, check after do Logger function (must be set)
    4) IP: In accordance with RHW-925 IP as input and must tick (must be set)
    5) Port: In accordance with RHW-925 Port as input and must tick (must be set)
    6) Save file: Select the Logger path to be stored (must be set)
    7) Alarm Beeper: After checking the SCREEN4-8-7 to tie the set , when they meet the conditions have an effect
    8) Alarm SMS: After checking the SCREEN4-8-7 to tie the set, when meet the conditions will send SMS
    D. In SCREEN4-8-6 the Save tool button, the value will be set according to Save the storage, and it will return to SCREEN4-8-4 screen when Step3 green and flashing that means the RHW-925 connection
    E. In SCREEN4-8-4 of Step4 (CH1) click on the picture into the SCREEN4-8-7, then do High and Low Set and checked, when you press the Return smart phone screen will return to SCREEN4-8-4 When the measured value have reached the condition CH1-CH3 will show red numbers and have Beeper and send SMS.
    F. In SCREEN4-8-4 of Step5 tool button to switch directly display the value of Meter1-Meter4
    G. Re-connect: When they find breaking news WiFi is not connected, you can press the function do reconnect action.
    H. Auto Log: Sampling time is set based on the time and checked, do the automatic recording function (such as SCREEN4-8-5).
    I. Manual Log: Each time you press the tool button, then record sum. Both formats Auto Log or Manual Log, archival records are xml .
    J. View Log: See the recorded data directly on smart phones (such as SCREEN4-8-8).

REMARK:
if use lutron sw-818 software, channels please setting to 12 CH .

Client Mode (internal network)

  1. First, you must prepare a wireless device as AP.
    This device set SSID for RHW-925 (by the user to determine the SSID name) Password not set

  2. The RHW-925 is set to Client mode, the relevant parameters are as follows:
    NetMode: Client
    SSID: RHW-925
    IP: 192.168.0.254
    Port: 200

  3. AS SCREE4-2-3 , SCREE4-2-4 .

Client Mode(External network fixed IP)

  1. Simple schematic network:

  2. . The RHW-925 is set to Client mode, the relevant parameters are as follows:
    NetMode: Client
    SSID: RHW-925
    IP: 192.168.0.254
    Port: 200
    Gateway: 192.168.0.1(With a smart phone in the App Store to download IP Tools, after the installation and execution can be learned)

  3. into the IP Router do parameter settings, the contents of the red box set you can do

  4. Execution Meter App, enter the need of parameters. IP item which required the use of IP Tools software to learn the input

4-11.Client Mode(External network floating IP):

  1. Simple schematic network:

  2. The RHW-925 is set to Client mode, the relevant parameters are as follows:
    NetMode: Client
    SSID: RHW-925
    IP: 192.168.0.254
    Port: 200
    Gateway: 192.168.0.1(With a smart phone in the App Store to download IP Tools,after the installation and execution can be learned)

  3. into the IP Router do parameter settings, the contents of the red box set you can do.

  4. Apply for free transfer to www.noip.com address, the name of the application will be transferred to the address input to the IP Router.

  5. Execution MeterApp, enter the need of parameters. IP item which required the use of IP Tools software to learn the input

Ethernet Mode connecter network floating (intenal network ):

  1. Simple schematic network:

  2. The RHW-925 is set to Client mode, the relevant parameters are as follows:
    IP: 192.168.0.254
    Port: 200
    Gateway: 192.168.0.1

  3. RJ45 connecter model as 3-19, Fig1.

Ethernet Mode connecter network floating ( external network ):

  1. Simple schematic network:

  2. The RHW-925 is set to Client mode, the relevant parameters are as follows:
    IP: 192.168.0.254
    Port: 200
    Gateway: 192.168.0.1

  3. RJ45 connecter model as 3-19, Fig1.

Ethernet Mode is connected via the wireless bridge network (External network fixed IP ):

  1. Simple schematic network:

  2. The RHW-925 is set to Client mode, the relevant parameters are as follows:
    IP: 192.168.0.254
    Port: 200
    Gateway: 192.168.0.1

  3. Enter the IP Router to set parameters,Set the contents of the red box.

  4. RJ45 connecter model as 3-19 , Fig1.

Ethernet Mode is connected via the wireless bridge network (External network Floating IP ):

  1. Simple schematic network:

  2. The RHW-925 is set to Client mode, the relevant parameters are as follows:
    IP: 192.168.0.254
    Port: 200
    Gateway: 192.168.0.1

  3. Enter the IP Router to set parameters,Set the contents of the red box.

  4. To www.dlinkddns.com apply for a free address, the application of the address name input to the IP Router.

  5. When the Metro App is implemented, the required parameters are entered using the IP Tools software as SCREEN4-8-4、 SCREEN4-8-5.

  6. RJ45 connecter model as 3-19 , Fig1.

RS232 Function SERIAL OUTPUT

The instrument is provided an 3.5 mm dia. Phone socket ( 3-17, Fig. 1 ) for RS232 computer interface socket.
The connector output is a 16 digits data stream which can be utilized to the user’s specific application.
A RS232 lead with the following connection will be required to link the instrument with the PC or NB USB port or serial port.

The 16 digits data stream will be displayed in the following format :

Each digit indicate the following status :

D15 Start Word
D14 4
D13 1 ~ 9
D12 & D11 D10 Annunciator for Display
01=℃ 02=℉

Polarity

0 = Positive

| 1 = Negative|
D9| Decimal Point(DP), position from right to the left 0 = No DP, 1= 1 DP, 2 = 2 DP, 3 = 3 DP
D8 to D1| Display reading, D1 = LSD, D8 = MSD For example : If the display reading is 1234, then D8 to D1 is : 00001234
D0| End Word

RS232 setting

Baud rate 9600
Parity No parity
Data bit no. 8 Data bits
Stop bit 1 Stop bit

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals