S18 Wearable Breast Pump
User Manual
Wearable Breast Pump
S18(2 Pump)
Read this user manual carefully before using your electric breast pump, and save the user manual for future reference.
Parts list
- Wearable breast pump x2
- Bra adjustment strap x2
- Small brush x2
- User manual x1
- 0.94inch/24mm flange insert x 2
- Type-c cable x2
- Storage bag x2
- Breastfeeding manual x1
Wearable breast pump
Assembling
- Put the silicone diaphragm into the milk collector, and press it with your hands to make the edges fasten tightly to ensure a perfect seal.
- Put the silicone shield into the breast milk collector and press it with your hands to make the edges tightly fastened. Make sure to install it in the correct direction.
- Install the pump motor on the breast milk collector to ensure that it fits perfectly with the breast milk collector.
- Connect the type-c charging cable to charge the battery.
Note:
- This product has a built-in li-lon battery. When the battery indicator lights red, we recommend that you use a certified 5V ****1A adapter to charge the pump motor as soon as possible.
- The power adapter is a common standard accessory on the market. This product is not provided and can be purchased separately if necessary. Power adapter specifications: 5V ****1A.
- The duration of pumping should be no more than 20 minutes.
- Check all parts for malfunction o r damage. Parts may need to be replaced in time.
Cleaning and sterilizing
- For the first time and before each use, you must disassemble, wash and sterilize all the breast pump parts that come into contact with breast milk.
- After use, please immediately disassemble and clean all parts in contact with breasts and breast milk (membrane, milk bottle,duckbill valve, shield) to avoid breast milk residue or bacterial growth; It is recommended to use drinking water or detergent for cleaning (Water temperature should not exceed 100°C, it will damage the part sand lead the to deformation of the parts).
Control panel
- Level down button
- Level up button
- Power button/Power display/Mode selection button
Operation cautions
- Made of non-toxic plastic. Don’t worry about any harmful chemicals leaching into your breast milk. You can wipe those parts clean with a soft cloth.
- Take care when cleaning the valve and the silicone diaphragm. If it gets damaged, your breast pump will not function properly.
- To clean the valve, rub it gently between your fingers in warm soapy water. Do not insert objects as this may cause damage.
Display description
-
Press the silicone shield firmly against the breast, leave no gaps, and make sure your nipple is centered. Keep it upright.
Be careful not to distort the position of the product and the chest, otherwise, the breast pump will not have suction power. -
Long press “ ” to start the breast pump.
-
Short press “ “” to switch the mode, and the indicator light flashes once to indicate the breast pumping mode. There are 12 gears in this mode. You can choose the suction power that is comfortable for you by pressing the “ +” and ” =” buttons. The l i g h t flashes once when you increase or decrease the first gear, and the light flashes three times when you increase it to the highest gear or reduce it to the lowest gear. During postpartum breastfeeding, breast pain, lumps, and other breast discomforts are prone to occur. Using this pumping mode can relieve breast problems.
-
Short press the “ ” again to switch to massage mode, and the indicator light flashes once. There are 12 gears in this mode, and you can press the “+” and “-” button to choose the suction power that makes you comfortable. Increase o r decrease one gear, the light flashes once, and the light flashes three times when it is increased to the highest gear or reduced to the lowest gear. In the early postpartum period, the lactiferous duct is not easy to conduct, and the breast can be stimulated by changing the mode to promote breast milk secretion.
-
Press “ ” to turn off the breast pump when finished long pumping, then carefully remove the breast pump from the breast.Massage mode: white light Breast pumping mode: orange light In the charging state: orange light flashes; in the full state: white light is always on; in the low battery state: the light in the current mode flashes.
Tips
- This model has a built-in memory function, when you turn on the machine again, the machine automatically enters and up shifts to the working mode and suction level you used last time.
- The breast pump will automatically stop after 30 minutes of work.
- When you wear the breast pump, relax and sit in a comfortable chair, leaning forward slightly (Use the cushion to support your back). In this way, the silicone shield of the breast pump can be slightly inclined upward, which facilitates the flow of breast milk into the milk collector and reduces the residual breast milk in the silicone shield.
Remote control panel instructions
- Red light/Green light
- Touch switch
- Upshift button
- Downshift button
- On/Off button/Mode switch button
- Battery cap
Remote control function introduction
Button description:
- Long press “ /M” t o control the power on/off of the breast pump.
- When the breast pump is turned on, short press “ /M” to switch the working mode of the breast pump.
- Short press “*+” to increase the gear. Short press once to increase one gear. Long press “+” for more than 300MS, continue to increase the gear.
- Short press “—” to decrease the gear, and short press once to decrease one gear. Long press “—” for more than 300MS, continue to decrease gear.
- When the touch function is unlocked, press and hold “ ”” for 2 seconds until the green light or red light goes out. At this time, the buttons are locked and they will not respond to pressing, which can avoid accidental touch. When the touch function is locked, press “ ” for 2 seconds until the green light or red light is on, indicating the buttons are unlocked successfully. Then the breast pump can be controlled wirelessly by touching these buttons.
Display description
- Green or red light will be on when “ “”+” “=” “ /M” i s pressed.
- When the remote control’s battery is full, the indicator light is green when the button is operated. The indicator light is off when the button is not operated. When the remote control is in low battery and is turning off soon, the indicator light is red when the button is operated, reminding to replace the battery as soon as possible. The indicator light is off when the button is not operated.
Tips
The remote control and the pump buttons are independent of each other and do
not interfere with each other. Breast pumps can be controlled either by
remotes o r by pressing the buttons on the pumps.
Pairing instructions
- Press the power button on the breast pump to turn it on.
- Press and hold the “+” and “—” buttons on the breast pump at the same time, and release the buttons after the light of the breast pump flashes.
- Then press the “-+” and “—” keys on the remote control at the same time. The light on the breast pump will immediately change from blinking to steady on, indicating a successful match.
Instructions for duckbill valve installation
Insert the raised part of the duckbill valve into the round hole at the bottom of the suction bowl groove of the bra.
Instructions for bra adjusting buckle
Adjusting the length of bra straps, makes pumping more comfortable. One end of the bra adjustment buckle hung on the inside buckle of nursing bra. Adjust the length of the bra buckle according to your preference.
Instructions for pouring milk
After you finish pumping, please remove the breast pump from the breast. Keep the breast pump upright and remove the motor part, hold the milk collector to pour the breast milk into a bottle, and make sure the milk collector gap of the breast cup is aligned with the mouth of the bottle to prevent breast milk spilled.
Storing your breast milk
Breast milk storag e
- Only store breast milk collected from sterilized breast pumps.
- The sucked milk should be placed in a clean and sterilized milk storage bag or a milk bottle with a seal, and immediately placed in the refrigerator to refrige- rate o r freeze.
Breast milk cold storage
- Do not refreeze breast milk twice.
- Do not mix fresh breast milk with frozen breast milk.
- Be sure to throw away any remaining breast milk after feeding.
- The pumped milk can be refrigerated in the refrigerator for 48 hours, o r frozen in the freezer for 3 months (Do not store breast milk in the door of the refrigerator or freezer ) . The milk bottle or milk storage bag can be affixed with a label clearly marking the milking date and time.
Thawing breast milk
Place the frozen breast milk in the refrigerator overnight to thaw. If you’re
in a hurry, the fastest way to defrost breast milk is to put it in a bowl of
warm water. The thawed breast milk must be consumed within 24 hours.
Heating breast milk
- Place the baby bottle with breast milk upright in a bowl of warm water or in a food heater to warm breast milk safely and quickly.
- Keep in mind! Before feeding your baby, be sure to check the temperature of breast milk.
- Do not use a microwave oven to heat breast milk as this may destroy important nutrients and antibodies.
- Uneven heating may lead to partial overheating of the milk and cause burns.
- Do not heat the baby bottle with breast milk in boiling water to avoid rupturing or cracking.
FAQ
Q : Why does the breast pump leak milk?****
– A : Possible reason 1 : You may be in an incorrect milking position.
– Solution: Please choose the most comfortable seated position for milking.
– Possible reason 2: The parts of the pump were not disassembled during
cleaning, resulting in the deformation of the product.
– Solution: Please disassemble all parts while cleaning the breast pump. If
the parts are deformed during use, please replace the accessories timely.
– Possible reason 3: The duckbill valve and milk collector are in poor
condition.
If they are damaged or aged, the milk cannot godown into the bottle and will
run out of the bra’s place.
– Solution: Please check if the product is in good condition before using it,
and replace it with new accessories in time.
Q : Why does the breast pump suck little breast milk?****
– A : The design principle of the breast pump is to imitate the action of the
baby sucks, stimulating the breast to secrete milk, and achieve the purpose of
expressing breast milk;
– If you feel that the effect of the breast pump is not obvious and hope to
pump more breast milk, you can place warm, wet washcloths on your breasts for
3 minutes in advance to activate your chest, and then use the automatic gear
or massage gear for 3 minutes, and then slowly adjust the gear to find out the
appropriate frequency for yourself.
Q : Can a breast pump with a lithium battery be taken on a plane?****
– A : Yes, although our breast pump has a built-in lithium battery, the capacity of it meets the flight safety requirements.
Q: Why does the breast pump have a plastic smell?****
– A : Please don’t worry, it’s normal for the product to have a slight smell. Our breast pumps are made of enviromental-friendly BPA-free PP and silicone materials. We recommend that you open the bag and box and put them aside for a day after receiving the goods. If you need it urgently, we suggest you wash it with white vinegar o r baking soda, and there will be no odor.
Q : What should mothers pay attention t o while breastfeeding?****
– A : 1. Before using the breast pump, we recommend that you use a hot towel
for about 3 minutes to encourage the breasts to open up and produce milk so
that the pumping speed will be faster.
– 2. When you use the breast pump, the gear of it should not be too large, you
just need to adjust to the gear you feel comfortable with. It is recommended
that mothers fully open the breasts with a massage or automatic block, and
then increase the suction.
– 3. Generally speaking, one breast can be pumped within 8 minutes, we
recommend that the maximum use time should not exceed 20 m i nutes.
Q : Why do feel the suction of my breast pump is too low?****
– A : Please check whether all parts are installed correctly and whether the breast pump is adjusted to the appropriate gear.
Product parameters
Model | S18 |
---|---|
Product name | MomMed Wearable Breast Pump |
Material | Food Grade Silicone, ABS |
Product size | 7.085.703.14inch/18014580mm |
Power input | 5V ****IA |
Lithium battery voltage | 3.7V |
Battery | 1000mAh, 1.85Wh |
Mode | Massage/Suction |
Silicone flange | 0.94inch/24mm Optional |
Silicone shleld | 1.06inch/27mm Optional |
Duration | 30mins |
Warranty card
Product Warranty Card
User Name……………………………..
Product Model………………………….
Product.Warranty Time………………….
Purchase Time…………………………………
Create with MomMed:
MomMed Super User Club
Activate Your Warranty Now
www.mommed.com
Follow the Instruction
Click “Activate Now”
Thank you for shopping with us. We will solve any problems of the products you have purchased from our company. We don’t stop caring about our products once they’re yours. By activating your standard warranty, we’re allowed to offer the best aftercare for your products and other possible issues.
support@mommed.com
Shenzhen TPH Technology Co., Ltd.
5th Floor, Building NO. 29 East Side, Lianchuang 2nd Technology Park,
Bulan Road, Longgang District, Shenzhen, China.
APEX CE SPECIALISTS LIMITED
89 Princess Street, Manchester, UK M1 4HT
Tel:+441616371080
E-Mail:info@apex-ce.com
APEX CE SPECIALISTS LIMITED
Unit 3D North Point House
North Point Business,Park New Mallow Road co.cork,
T23 AT2P lreleand
Tel:+353212066339
E-Mail:info@apex-ce.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>