HOLDLAMP ZQ01449US 3 Pcs LED Par Light Bat User Manual
- June 13, 2024
- HOLDLAMP
Table of Contents
- SAFETY INSTRUCTIONS
- INSERTION OF THE BATTERY IN THE REMOTE CONTROL
- REMOTE CONTROL
- DMX OPERATION
- SPECIFICATIONS
- BUTTONS & CONNECTORS
- FUSE REPLACEMENT
- CABLE CONNECTORS
- DMX CONNECTOR CONFIGURATION
- FIXTURE LINKING
- SETTING UP A DMX SERIAL DATA UNK
- MASTER/SLAVE FIXTURE UNKING
- DMX ADDRESS SETTING
- MENU MAP
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HOLDLAMP ZQ01449US 3 Pcs LED Par Light Bat User Manual
WARNING:
FOR YOUR OWN SAFETY,PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR
INITIAL START-UP!
CAUTION :
Keep this equipment away from rain, moisture and liquids.
SAFETY INSTRUCTIONS
Every person involved with the installation, operation & maintenance of this equipment should:
- Be competent
- Follow the instructions of this manual
CAUTION :
Take care using this equipment! high voltage-risk of electric shock!!
Before your initial start-up,please make sure that there is no damage caused during transportation.Should there be any,consult your dealer and do not use the equipment.
To maintain the equipment in good working condition and to ensure safe operation,it is necessary for the user to follow the safety instructions and warning notes written in this manual.
Please note that damages caused by user modifications to this equipment are not subject to warranty.
ATTENTION:
DANGER OF LIFE! RISK OF BURNS! RISK OF FIRE! RISK OF SHORT CIRCUIT!
CAUTION:
DO NOT OPEN THE HOUSING SHOCK HAZARD
IMPORTANT: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unatuhorized modification to the equipment.
- Please read these instructions carefully, they include important information about the installation, usage and maintenance of this product.
- Please keep this User Guide for future reference. If you sell the unit to another user, be sure that he also re-ceives this instruction booklet.
- Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the bottom of the fixture.
- This product is intended for indoor use only!
- To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable materials close to the unit while operating.
- The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be sure that no ventilation slots are blocked.
- The minimum distance luminaire from that part of the luminaire or lamp to the lighted object is 0.5m.
- Maximum ambient temperature (Ta) is 104° F (40°C). Don’t operate the fixture at higher temperatures.
- In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type of spare parts.
- Make sure the power cord is never crimped or damaged.
- The light source is not replaceable. If it is faulty, the whole unit must be discarded.
- Avoid direct eye exposure to the light source while it is on.
INSERTION OF THE BATTERY IN THE REMOTE CONTROL
Pull out the battery compartment and insert a button cell (CR2025 3V) with the positive side facing upwards. Push in the battery compartment until it clicks into place.
ATTENTION: Danger of explosion flattery is incorrectly placed. Only rep/ace by the same or equivalent type. Keep new and old batteries out of the reach of children. he the battery compartment doesn’t close properly, stop using the product and keep it out of the reach of children.
WARNING: The supplied remote control contains a button cell In case of ingestion, it might cause serious internal burns within only 2 hours that might lead to death. If you are in doubt whether the batteries have been swallowed or introduced into any other part of the body, contact imme-diately a doctor.
REMOTE CONTROL
- Dimmer & Speed, 1 Button
- Dimmer & Speed, I Button
- OFF
- ON
- R G B W Single color
- 1-9: 9 kinds of static mixing color (AC 1 AC 9)
- 0:A001 mode. Press up & down to select address
- AUTO: Change color mode. Press up & down to select speed
- STROBE: Select color strobe mode (15 kinds of colour)
- Press up & down to select speed
- FADE: gradual change mode. Press Up & down to adjust speed
- SOUND: Sound mode. Press up & down to select mode.
DMX OPERATION
CHs | 4CHs | 6CHs | __**8CHs** |
---|---|---|---|
CH1 | 1-255 Red dimmer | 1-255 Master Dimmer | 1-255 Master Dimmer |
CH2 | 1-255 Green dimmer | 1-10 Off, 11-255 Strobe (Slow to fast) | 1-255 Red |
Dimmer
CH3| 1-255 Blue dimmer| 1-255 Red Dimmer| 1-255 Green Dimmer
CH4| 1-255 White dimmer| 1-255 Green Dimmer| 1-255 Blue Dimmer
CH5| | 1-255 Blue Dimmer| 1-255 White Dimmer
CH6| | 1-255 White Dimmer| 1-10 Off, 11-255 Strobe (Slow to fast)
CH7| 1-10 Off
CH8| 11-50 Color mixing
51-100Jump change
101-150 Gradual change
151-200 Mutation mode
201-220 Controller jump change Sound mode
221-240 Controller color change strobe Soundmode
241-255 Controller mutation Sound mode
1-255 Speed (Slow to fast)
SPECIFICATIONS
Voltage: 220-240V– 50/60Hz
Built-in battery Lithium 12: 4400mAh
Fuse: 1A 250V
Light source: 3PCS 4 in 1 LED, RGBW
Control mode: Sound control, Auto-run, Master/Slave, DMX512
Max.: Ta 40°C
Channel: 4 / 6 /8 DMX channels
BUTTONS & CONNECTORS
- Control panel
- Display
- Battery level indicator
- Microphone
- DMX input connector
- DMX output connector
- ON/OFF switch
- IEC mains connector
- Power output
- Fuse
BUTTON FUNCTIONS OF THE CONTROL PANEL
MENU: Scrolls through the first level of options, or exits from the
current menu or function
UP: Navigates upward through the menu list or increases the numeric value
when in a function
DOWN: Navigates downward through the menu list or decreases the numeric
value when in a function
ENTER: Enables the currently displayed menu or sets the currently
selected value in to the current function
FUSE REPLACEMENT
Locate and remove the unit’s power cord. Once the cord has been removed located the fuse holder located inside the power socket. Insert a flat-head screw driver into the power socket and gently pry out the fuse holder. Remove the bad fuse and replace with a new one.
Warning: If after replacing the fuse you continue to blow fuses, STOP using the unit. Contact customer support for further instructions. Continuing to use the unit may cause serious damage.
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XIS connector on the other end.
DMX CONNECTOR CONFIGURATION
Termination reduces signal errors. To avoid signal transmission problems and
interfe-rence, it is always advisable to connect a DMX signal terminator.
CAUTION
Do not allow contact between the common and the fixture’s chassis ground.
Groun-ding the common can cause a ground loop, and your fixture may perform
erratically. Test cables with an ohm meter to check correct polarity and to
make sure the pins are not grounded or shorted to the shield or each other.
FIXTURE LINKING
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all fixtures on a serial data link determines the number of fixtures that the data link can support.
SETTING UP A DMX SERIAL DATA UNK
- Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the controller.
- Connect the end of the cable coming from the controller which will have a (female) 3 pin connector to the Input connector of the next fixture consisting of a (male) 3 pin connector.
- Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
MASTER/SLAVE FIXTURE UNKING
Connect the (male) 3 pin connecter side of the DMX cable to the output (female) 3 pin connecter of the first fixture. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connecter to the input connecter of the next fixture consisting of a (male) 3 pin connecter. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
DMX ADDRESS SETTING
Each fixture must have a specific starting address. When receiving signal transmission, every fixture will receive channels control signals for its own starting address.
The user can set several fixtures to the same address or set up a separate address for every device.
If more than one fixture is set to the same address, all of them receive the same DMX channels signals. All connected fixtures are jointly controlled; the controller can’t control a device separately.
If every device is set to a different address, it will receive different DMX signals corresponding to Its starting address.
MENU MAP
DISPLAY | FUNCTION |
---|---|
A001 | A001—A512 |
Chnd | 4CH |
6CH | 6 channels |
8CH | 8 channels |
FAIL | BLND |
HOLd | In case of failure, settings are kept in memory and restored |
CLO1 | CL01—CL15 |
to choose a color. Enter – Strobe mode, St0O-St16, Adjust the strobe via the
UP & DOWN buttons.
---|---|---
AUTO| AUTO| All Effects mode, Enter -Speed mode, SP01-SP16. Adjust the speed
via the UP & DOWN buttons.
AUT1| Auto Colour change mode. Enter -, Set the speed, SP01-SP16, Adjust the
speed via the UP & DOWN buttons.
AUT2| Auto Gradual change. Enter -> Set the speed
AUT3| Auto colour jump mode. Enter – Set the speed
AUTO| Auto Strobe Colour change mode. Enter -) Set the speed
SOU1| SOUO| All sound-controlled modes SNOO-SN99 Sound sensitivity
SOU1| Sound-controlled Colour change SNO0 -SN99 Sound sensitivity
SOU2| Sound-controlled colour jump SNOO-SN99 Sound sensitivity
SOU3| Sound-controlled strobe colour change SNO0 -SN99 Sound sensitivity
NANU| D000-255| Master Dimmer
R000-255| Red Dimmer
G000-255| Green Dimmer
B000-255| Blue Dimmer
W000-255| White Dimmer
S000-255| Strobe Speed
TEST| | Color self check
LED| ON| Digital display On
| OFF| Digital display Off
IRCL| ON| Remote On
| OFF| Remote Off
VER| 2.0| Software version No.
ADVANCED DATA SETTING: (A001 MODE PRESS ENTER FOR 3 SECONDS TO CONFIRM)
R | 000-255 | Red LED current adjustment |
---|---|---|
G | 000-255 | Green LED current adjustment |
B | 000-255 | Blue LED current adjustment |
W | 000-255 | White LED current adjustment |
L | LON | Current adjustment mode (All LEDs On) |
LOFF | Current adjustment mode (single color) | |
F | F006 | 600HZ refreshment of frequency |
F012 | 1.2K refreshment of frequency | |
F020 | 2K refreshment of frequency | |
4K refreshment of frequency | ||
F120 | 12K refreshment of frequency | |
F240 | 24K refreshment of frequency | |
T | T000 | Temperature display (°C) |
N | NOFF | Intelligent temperature off |
N065 | Intelligent temperature on (40-95°C power decrease setting. Above |
95°C, Light will turn off)
D| DON| Dimmer delay On
| DOFF| Dimmer delay Off
C| C 0| Linear curve
| C 1| Square curve
| C 2| Logarithmic curve
| C3| S curve