DIMENSION

Use for appliances with the following maximum dimensions

APPLICATION

This glass hearth pad will provide the necessary floor protection for appliances that require only ember protection. This product is not to be used with appliances that specify thermal floor protection with a specific R-value requirement.

This floor protection can be used with the following:

  • Solid-fuel type room heaters complying with the Standard for Room Heaters, Solid-Fuel type UL 1482, UL 737, ULC S627;
  • Solid-fuel type room heaters complying with the Standard for Room heaters, Pellet Fuel-Burning Type, ASTM E1509, ULC S627.

SPECIFICATIONS

CLEAR TINTED BLACK
  • Dimensions – AC02761 : 70″ x 20″;

|

  • Dimensions – AC02757 : 44″ x 36″;

  • Dimensions – AC02703 : 54″ X 46 ¾”;

|

  • Dimensions – AC02758 : 54″ X 46 ¾”;

  • Dimensions – AC02760 : 50″ x 18″;

|

  • Dimensions – AC02704 : 44″ X 36″;

|

  • Facteur R = 0;

  • Nominal glass thickness : 10 mm.

KIT CONTENTS

RECOMMENDED FOR INSTALLATION

SAFETY INFORMATION

The minimum floor protection area must be at least that specified in the heating appliance installation instructions. Always refer to the certification plate on the appliance for the floor area to protect.

This floor protection:

  • Must not be cut or trimmed;
  • Must not be installed on a carpeted surface;
  • Must not be installed side by side with another floor protection;
  • Must be installed in accordance with local building code;
  • Must be installed on a continuous, flat and level surface.
  • If installed with a zero clearance fireplace, the joint between the wall and the floor protection must be sealed with non combustible material.

WARNING

HOT SURFACE WHEN THE HEATING APPLIANCE IS IN OPERATION.

INSTALLATION

  1. Carefully unpack the glass hearth pad and secure it in a safe location, while preparing the floor for the installation.
  2. Clean the floor area where the hearth pad will be installed. It must be free of debris or any other materials that could cause the glass to set unlevel and potentially break.
  3. Clean thoroughly the underside of the hearth pad. Once the pad is in place it will be impossible to clean the underside without lifting it up again. This step is very important as glass will show the slightest imperfection or smear.
  4. Carefully place the back edge of the glass pad in position it will be in, then lower the glass pad down and gently place on the floor. Once flat on the floor, inspect for smears or debris that could be under the glass. Using a bright flashlight is recommended. Ensure the glass pad is in the correct location.
  5. Lift the appliance and place into the desired position. Be careful not to scratch the glass.
  6. Clean the surface thoroughly.

MAINTENANCE

Clean glass with wood stove glass cleaner and paper towel or damp cloth. Never clean when the hearth pad or the appliance is hot.

WARRANTY TERMS AND CONDITIONS

PRODUCT WARRANTY: 1-YEAR LIMITED WARRANTY

SBI Heating Accessories, warrants this Glass Hearth Pad meets the CAN/CGSB 12.1-2017 and CAN/CGSB 12.3-M91 (R2017) standards. During the one-year warranty of this product, SBI Heating Accessories, will dispense, at their discretion, parts and labour to correct any defect who does not meet the standards mentioned above. This warranty applies to the original owner with a proof of purchase and is not transferable.

For replacement, phone418-908-8002

This warranty applies only to products which have not been subjected to negligent use, misuse, alteration or accident. This warranty supersedes all other warranties either expressed or implied and all other obligations or liabilities on our part. SBI Heating Accessories, does not assume, and does not authorize any other person to assume for us, any liability in connection with the sale of our products.
To be at “No Charge,” warranty work must be sent directly to SBI Heating Accessories, or one of our authorized service centers and performed by them. To obtain warranty service or replacement instructions, contact our customer service department at 418 908-8002 Monday through Friday from 8 a.m. to 5 p.m. SBI Heating Accessories, retains the right to change models, specifications and price without notice.

Distributed under SBI Heating Accessories.
Manufactured by Clearlight, Inc.

This document is available for free download on the manufacturer’s website. It is a copyrighted document.
Resale is strictly prohibited. The manufacturer may update this document from time to time and cannot be responsible for problems, injuries, or damages arising out of the use of information contained in any document obtained from unauthorized sources.

CUSTOMERS SUPPORT

SBI HEATING ACCESSORIES
250 rue de Copenhague
St-Augustin-de-Desmaures
Québec, Canada G3A 2H3
418-908-8002
tech@sbi-international.com
logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Drolet User Manuals

Related Manuals