Safety Warning
These products are only suitable for connection to a 240V~50Hz supply in
accordance with current IEE wiring Regulations and should be installed in
accordance with local Building Regulations and are for Domestic indoor ceiling
use only and are not suitable for a Bathroom location. The light fitting
should be connected to a lighting circuit protected by a 5 amp fuse (or a 6
amp miniature circuit breaker).
If in doubt we recommend you contact a qualified electrician. Before
installing your light fitting always:
Switch off the mains supply and remove the appropriate fuse or switch off the
appropriate circuit breaker before commencing installation.
Ensure that no one else has access that would enable the supply to be
inadvertently reconnected.
Never fit bulbs of a higher wattage or of a type other than those specified on
the label as this may cause overheating and damage the fitting.
This fitting is heavy and you may require assistance in connecting it to the
supply and securing it to the mounting surface. When fixing to the mounting
surface ensure that the fixings used are appropriate for the mounting surface
on which they are being used.
The bulbs become hot during use so please switch off and allow 10 minutes to
cool before replacing bulbs or cleaning the fitting.
Clean with a dry cloth only. Do not use liquid or abrasive cleaners on this
product.
If any modification is made it will invalidate the warranty and may render the
product unsafe.
Before you start
Please read these instructions carefully before fitting your new light and
retain for reference. Make sure that there are no pipes or cables beneath the
mounting surface. Check the packaging and make sure that you have all the
required parts. Follow each assembly step in order to prevent incorrect
assembly. Make sure all screws / nuts, including electrical connections etc
are fully tightened before use. This type of Light Fitting may be connected to
a Dimmer if a Tungsten incandescent bulb is used. If a CFL type bulb is fitted
then these cannot (generally) be controlled by a dimmer.
The Light pack contains: Light fitting and mounting bracket. Terminal
connection block(s).
The following tools may be required: Selection of cross and flat head
screwdrivers. Electric drill and assorted drill bits. Wire strippers.
Electrical insulation tape.
Assembly/ User Instructions
These assembly diagrams are intended as a guide — if in doubt consult a
qualified electrician.
Diagram C
Wiring Details
Diagram C
-
Decide on the position of the light fitting / or remove existing light fitting. Take a note of the position of the electrical connections. Ensure there is a solid mounting surface, preferably a wooden joist or joist bridge to support the weight of the light fitting.
-
See Diagram A. Remove the fixing bracket by undoing the 2 side screws
(1). Retain these for re-use. Use this bracket
(2) as a template to mark the screw holes, mark the screw holes and secure to the ceiling with the screws supplied (3). -
Diagram B. If you want to reduce the overall length of the fitting it is essential that this is done before the fitting is mounted to the ceiling and / or connected to the mains supply. Remove the appropriate number of chain links as shown until the desired length is reached. The cable must now be shortened and the excess cable cut and re-connected to the terminal block. Make a note of the position of the cables in the terminal block. Feed the cable up and form a loop above the ceiling cup. Move the cable anchor down the cable —from (A) to (B). This is a strain relief device and must be used Cut off the excess cable and reconnect to the terminal block.
NOTE: The electric cable must always be longer than the Chain to prevent strain being placed on the cable. If you are unsure about your ability to do this, we recommend you contact a qualified electrician. -
Support your fitting – be careful as this unit Is heavy and you will require assistance) and connect the house wiring to the terminal block (4)- see wiring details.
NOTE: This is a Class I fitting and must be earthed. All earth cables must be connected to the terminal block. Any loose terminal blocks —not secured to ceiling cup – should always be covered with 2 layers of good quality insulation tape. -
Diagram C. Re-fit the unit to the ceiling bracket. Make sure that all the internal cables and connections are inside the ceiling cup taking care not to trap or strain the internal cables.
-
Fit the bulb (5) into the lamp holder.
NOTE; Never fit bulbs of a higher wattage or of a type other than those provided / specified on the label (as these may cause overheating and damage the fitting). -
Use the screws (6) to secure the decorative shade to its holder (7).
-
Turn on the power and test.