ARISTON AH 90 CLM IX Home & Kitchen Appliances User Guide
- June 13, 2024
- Ariston
Table of Contents
Instructions for use
AH 90 CM IX
GENERAL SAFETY
- Before any cleaning or maintenance operation, disconnect hood from the mains by removing the plug or disconnecting the mains electrical supply.
- Always wear work gloves for all installation and maintenance operations.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Children shall not be allowed to tamper with the controls or play with the appliance.
- Cleaning and user maintenance shall not be made by children without supervision.
- The premises where the appliance is installed must be sufficiently ventilated, when the kitchen hood is used together with other gas combustion devices or other fuels.
- The hood must be regularly cleaned on both the inside and outside (AT LEAST ONCE A MONTH).
- This must be completed in accordance with the maintenance instructions provided. Failure to follow the instructions provided regarding the cleaning of the hood and filters will lead to the risk of fires.
- Do not flambé under the range hood.
- For lamp replacement use only lamp type indicated in the Maintenance/Replacing lamps section of this manual.
The use of exposed flames is detrimental to the filters and may cause a fire
risk, and must therefore be avoided in all circumstances. Any frying must be
done with care in order to make sure that the oil does not overheat and
ignite.
CAUTION: Accessible parts of the hood may become hot when used with cooking
appliances.
- Do not connect the appliance to the mains until the installation is fully complete.
- With regards to the technical and safety measures to be adopted for fume discharging it is important to closely follow the regulations provided by the local authorities.
- The air must not be discharged into a flue that is used for exhausting fumes from appliance burning gas or other fuels.
- Do not use or leave the hood without the lamp correctly mounted due to the possible risk of electric shocks.
- Never use the hood without effectively mounted grids.
- The hood must NEVER be used as a support surface unless specifically indicated.
- Use only the fixing screws supplied with the product for installation or, if not supplied, purchase the correct screws type.
- Use the correct length for the screws which are identified in the Installation Guide.
- In case of doubt, consult an authorized service assistance center or similar qualified person.
WARNING!
- Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards.
- Do not use with a programmer, timer, separate remote control system or any other device that switches on automatically.
The hood can look different to that illustrated in the drawings in this
booklet. The instructions for use, maintenance and installation, however,
remain the same.
Closely follow the instructions set out in this manual. All
responsibility, for any eventual inconveniences, damages or fires caused by
not complying with the instructions in this manual, is declined. This
appliance is intended to be used in household and similar application such as:
– staff kitchen areas in shop, offices and other working environments; – farm
houses; – by clients in hotels, motels and other residential type
environments; – bed and breakfast type environments.
- It is important to conserve this booklet for consultation at any moment. In the case of sale, cession or move, make sure it is together with the product.
- Read the instructions carefully: there is important information about installation, use and safety.
- Do not carry out electrical or mechanical variations on the product or on the discharge conduits.
- Before proceeding with the installation of the appliance verify that there are no damaged all components. Otherwise contact your dealer and do not proceed with the installation.
The minimum distance between the supporting surface for the cooking equipment
on the hob and the lowest part of the range hood must be not less than 50cm
from electric cookers and 65cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater
distance, this must be adhered to.
Expansion wall plugs are provided to secure the hood to most types of
walls/ceilings. However, a qualified technician must verify suitability of the
materials in accordance with the type of wall/ceiling. The wall/ceiling must
be strong enough to take the weight of the hood.
Do not tile, grout or silicone this appliance to the wall. Surface mounting
only.
ELECTRICAL CONNECTION
The mains power supply must correspond to the rating indicated on the plate situated inside the hood. If provided with a plug connect the hood to a socket in compliance with current regulations and positioned in an accessible area, after installation. If it not fitted with a plug (direct mains connection) or if the plug is not located in an accessible area, after installation, apply a double pole switch in accordance with standards which assures the complete disconnection of the mains under conditions relating to over-current category III, in accordance with installation instructions.
WARNING!
Before re-connecting the hood circuit to the mains supply and checking the
efficient function, always check that the mains cable is correctly assembled.
Replacing the power cable
Warning! If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order to
avoid hazard.
AIR VENT
(for the suction versions)
Connect the hood and discharge holes on the walls with a diameter equivalent
to the air outlet (connection flange).
Using the tubes and discharge holes on walls with smaller dimensions will
cause a diminution of the suction performance and a drastic increase in noise.
Any responsibility in the matter is therefore declined.
! Use a duct of the minimum indispensable length.
! Use a duct with as few elbows as possible (maximum elbow angle: 90°).
! Avoid drastic changes in the duct cross-section.
! The company declines any responsibility whenever these regulations are not
respected.
FILTERING OR DUCTING ?
! Your cooker hood is ready to be used in suction version.
To use the hood in filtering version the special ACCESSORY KIT must be
installed.
Check on the first pages of this manual if the ACCESSORY KIT is furnished or
must be bought separately.
Note: If furnished, in certain cases, the additional activated carbon
filtering system may be installed on the hood.
Information about the conversion of the hood from suction version to filtering
version is present in this manual.
Ducting version
In this case the fumes are conveyed outside of the building by means of a
special pipe connected with the connection ring located on top of the hood.
CAUTION!
The exhausting pipe is not supplied and must be purchased apart.
Diameter of the exhausting pipe must be equal to that of the connection ring.
CAUTION!
If the hood is supplied with active charcoal filter, then it must be removed.
Filter version
The aspirated air will be degreased and deodorised before being fed back
into the room.
In order to use the hood in this version, you have to install a system of
additional filtering based on activated charcoal.
CONTROLS
The hood is fitted with a control panel with aspiration speed selection control and a light switch to control cooking area lights.
a. ON/OFF light switch
b. Speed 1/OFF switch
c. 2-speed selection
d. 3-speed selection
MAINTENANCE
Cleaning
Clean using ONLY the cloth dampened with neutral liquid detergent. DO
NOT CLEAN WITH TOOLS OR INSTRUMENTS. Do not use abrasive products. DO NOT
USE ALCOHOL!
Maintenance of the anti-grease filters
Traps cooking grease particles.
The grease filter must be cleaned once a month using non aggressive
detergents, either by hand or in the dishwasher, which must be set to a low
temperature and a short cycle. When washed in a dishwasher, the grease filter
may discolor slightly, but this does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle.
Maintenance of the charcoal filter
It absorbs unpleasant odors caused by cooking.
The saturation of the charcoal filter occurs after more or less prolonged
use, depending on the type of cooking and the regularity of cleaning of the
grease filter.
In any case it is necessary to replace the cartridge at least every four
months.
The charcoal filter may NOT be washed or regenerated.
Remove the grease filters.
Apply one charcoal filter each side and hook in onto the hood.
Refit the grease filter.
Replacing lamps
Disconnect the appliance from the electricity.
Warning! Prior to touching the light bulbs ensure they are cooled down.
Replace the old light bulb with the one of the same type as specified in the
feature label or near the light lamp on the hood.
Extract the drawer completely.
Remove the grill.
Remove the damaged light and replace it with a new one (see the table below):
Lamp
| Power (W)| Socket
---|---|---
| 28|
E14
Voltage (V)
| Dimension (mm)
230|
67 (Light Center Length)
ILCOS D Code
(according IEC 61231)
HSGSB/C/UB-28-230-E14-67
Put the grill back.
DISPOSAL
- This appliance is marked according to the European directive 2012/19/EC on Waste Electrical and Electronic Equipment (WEEE).
- By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.
- The symbol on the product, or on the documents accompanying the product, indicates that this appliance may not be treated as household waste. Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment. Disposal must be carried out in accordance with local environmental regulations for waste disposal.
- For further detailed information regarding the process, collection and recycling of this product, please contact the appropriate department of your local authorities or the local department for household waste or the shop where you purchased this product.
Appliance designed, tested and manufactured according to:
- Safety: EN/IEC 60335-1; EN/IEC 60335-2-31, EN/IEC 62233.
- Performance: EN/IEC 61591; ISO 5167-1; ISO 5167-3; ISO 5168; EN/IEC 60704-1; EN/IEC 60704-2-13; EN/IEC 60704-3; ISO 3741; EN 50564; IEC 62301.
- EMC: EN 55014-1; CISPR 14-1; EN 55014-2; CISPR 14-2; EN/IEC 61000-3-2; EN/IEC 61000-3-3. Suggestions for a correct use in order to reduce the environmental impact: Switch ON the hood at minimum speed when you start cooking and kept it running for few minutes after cooking is finished. Increase the speed only in case of large amount of smoke and vapor and use boost speed(s) only in extreme situations. Replace the charcoal filter(s) when necessary to maintain a good odor reduction efficiency. Clean the grease filter(s) when necessary to maintain a good grease filter efficiency. Use the maximum diameter of the ducting system indicated in this manual to optimize efficiency and minimize noise.
MALFUNCTIONS
If something appears not to be working properly, do the following simple checks before calling Technical Service:
-
If the hood is not working:
Check that:
– The power has not been disconnected.
– A speed has been selected. -
If the hood performs inefficiently:
Check that:
– The motor speed selected is sufficient for the amount of smoke and vapours released.
– The kitchen is sufficiently ventilated to allow air intake.
– The charcoal filter is not worn (hood in filtering version). -
If the hood has turned off during normal functioning:
Check that:
– The power has not been disconnected.
– the omnipolar disconnection device has not tripped.
If the hood fails to operate correctly, briefly disconnect it from the mains power supply for almost 5 sec. by pulling out the plug. Then plug it in again and try once more before contacting the Technical Assistance Service.
TECHNICAL DATA
Model AH 90 CM IX
Height 32,4 cm
Width 89,8 cm
Depth 30,2 cm
Gross weight: 14,6 Kg
Total absorption 231 W
Motor absorption 175 W
Lamp absorption 2×28 W (Ø35mm E14 )
Exhaust pipe Ø 15 cm
This appliance conforms to the following EEC Directive:
- “Low Voltage Equipment” Directive 2014/35/EU (26-02-2014)
- “Electromagnetic Compatibility” Directive 2014/30/EU (26-02-2014)
Components not provided with the product
LIB0092796C
Ed. 02/17