EXTECH AN250W Windmeter Bluetooth Connectivity with the ExView Mobile App User Manual
- June 13, 2024
- EXTECH
Table of Contents
- EXTECH AN250W Windmeter Bluetooth Connectivity with the ExView Mobile App
- Product Information
- Product Description
- Introduction
- Safety
- FCC Compliance
- Product Description
- Operation
- Maintenance
- Specifications
- Two-year Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
EXTECH AN250W Windmeter Bluetooth Connectivity with the ExView Mobile App
Product Information
The AN250W Anemometer User Manual provides detailed information on the usage and specifications of the product.
Safety
Please read all safety information before using this device.
FCC Compliance
The product complies with FCC regulations. To ensure proper operation, follow the guidelines provided in the manual:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Product Description
The AN250W Anemometer is a vane anemometer with a built-in temperature sensor. It features a backlit LCD for easy reading and function buttons for convenient operation. The meter also includes a tripod mount and a battery compartment.
Function Buttons
The AN250W Anemometer has various function buttons for different operations. Please refer to the manual for detailed instructions on how to use each button.
Operation
The AN250W Anemometer offers several operation features:
- Powering the Meter
- Auto Power Off (APO)
- Taking Measurements
- Changing Measurement Units
- Data Hold Function
- LCD Backlight
- MAX/AVG Readings
- Bluetooth Operation
Maintenance
To ensure proper functioning, follow these maintenance guidelines:
- General Cleaning
- Battery Replacement
Specifications
The AN250W Anemometer has the following specifications:
- General Specifications
- Measurement Specifications
- Environmental Specifications
- Connectivity Specifications
Two-year Warranty
The AN250W Anemometer comes with a two-year warranty. The warranty covers calibration and repair services. For any issues or inquiries, please contact customer support.
Introduction
- Thank you for selecting the Extech AN250W Anemometer. This meter meas-ures air velocity and temperature. The vane, situated at the top of the meter, measures the velocity of moving air and includes a sensor that measure air temperature.
- The air velocity and temperature readings are shown on the top and bottom rows of the LCD, respectively. The AN250W also displays air velocity in the Beaufort scale (1 to 12).
- The meter includes Bluetooth connectivity, MAX/AVG memory, selectable units of measure, auto power off, data hold, backlit LCD, and a tripod mount.
- Using the Extech ExView mobile app, you can pair your smart devices with the meter using Bluetooth. The app and the W Series meters were developed together for seamless integration. Download the free app from the App Store (iOS®) or from Google Play (Android™).
- This quality instrument is designed to provide years of reliable service, high accuracy and simple operation. Please visit the Extech website for additional information and world-class support.
Safety
Please read all safety information before using this device
CAUTION
- Check for damage to the device’s housing, sensor, display, and battery compartment before use. If obvious damage or abnormalities are noticed, please discontinue use and return the device for service.
- Do not attempt to open the meter housing or access the sensor module. There are no user-serviceable components in this device.
- Replace the batteries immediately after the low battery symbol appears. If the device is to be stored for a period of months, please remove the batteries and store separately.
- Do not store the device in high temperature or humidity environments, in flammable or combustible areas, or where a strong electromagnetic field is present.
- This device is CE certified.
FCC Compliance
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruc-tions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television recep-tion, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WARNING
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Product Description
Meter Description
- Vane anemometer with temperature sensor
- Backlit LCD (detailed below)
- Function buttons (detailed below)
- Tripod mount
- Battery compartment
Function Buttons
Display Symbols
- Maximum reading
- Average reading
- Data Hold mode
- Low battery symbol
- Air Velocity measurement and units
- Temperature reading and units
- Bluetooth active
- Auto Power Off (APO) symbol
- Beaufort scale abbreviation
- Beaufort measurement scale (1 to 12)
Operation
Powering the Meter
The meter operates on three (3) 1.5 V (AAA) batteries, installed in the rear
compartment.
Long press the power button to switch the meter on. Short press the power
button to switch the meter off. If the meter does not switch on, check the
bat-teries for proper orientation.
When the low battery symbol appears on the display, replace the batteries
immediately to ensure accurate readings.
Auto Power Off (APO)
The meter switches off automatically five (5) minutes after the last button
press.
The default mode for APO is ON (the APO symbol on the display indicates that
APO is enabled).
To switch the APO function off, with the meter switched on, long press the
power and data hold (H) buttons. The APO symbol will switch off, indicating
that the function is disabled. APO is reset each time the meter’s power is
cycled.
Repeat this process to switch APO back on manually.
Taking Measurements
- Long press the power button to switch the meter on.
- Hold the meter with the vane positioned in the flow of air. Allow the air to enter the vane from the back of the meter. The meter can also be tripod mounted.
- Read the velocity measurement on the top row of the LCD. The air temper-ature reading is shown on the bottom row.
- The Beaufort scale readings (1 to 12), are represented in the text boxes on the left side of the LCD.
- If an air velocity or air temperature measurement is outside the specified range, OL will appear on the display in place of a typical reading.
- Short press the power button to switch the meter off.
CAUTION
- Do not touch or otherwise obstruct the sensor area.
- Do not allow liquids to come in contact with the sensor.
- Avoid overly dusty environments.
- Magnetic induction can affect the sensor’s ability to operate correctly. Keep the sensor away from magnetic fields.
Changing Measurement Units
To step through the air velocity units menu, short press the UNIT button. The
air velocity units are m/s (meters per second), km/h (kilometres per hour),
ft/min (feet per minute), mph (miles per hour), and knots.
Long press the UNIT button to toggle the displayed temperature units ℃ / ℉.
Data Hold Function
Short press the Data Hold (H) button to freeze/unfreeze the displayed read-
ings. While Data Hold is active, HOLD will appear on the LCD.
LCD Backlight
Long press the backlight button to switch the display backlight on or off.
Excessive use of the backlight will shorten battery life.
MAX/AVG Readings
When the device is switched on, it begins tracking the highest (MAX) and
average (AVG) readings.
Short press the MAX/AVG button to step through the MAX/AVG memories. MAX is
shown when the maximum reading is displayed and AVG is shown when the Average
reading is displayed. The memories are cleared each time the meter power is
cycled.
Press the MAX/AVG button again to exit this mode (MAX and AVG symbols are both
off when you exit).
Bluetooth Operation
Long press the Bluetooth button with the meter on, to switch Bluetooth on or
off. This communication symbol is shown when Bluetooth is on.
The Bluetooth utility allows you to remotely monitor readings on an iOS or An-
droid smart device using the Extech ExView mobile app designed for use with
this meter.
Download the mobile app from the App Store for iOS devices or from Google Play
for Android devices. Instructions for mobile app use are available from the
ExView product page on the Extech website (link below).
http://www.extech.com
Switch APO off when using Bluetooth by pressing and holding the power and H
buttons for 2 seconds (the APO symbol will switch off). This will pre-vent the
meter from automatically switching off while you are logging data or
monitoring readings in real time on your smart device.
Maintenance
CAUTION
Warning: Do not open the housing or sensor module. Service should only be
performed by factory personnel, there are no user-serviceable components in
this device.
General Cleaning
Wipe the housing with a dry cloth as necessary to clean. Do not use abrasives
or solvents to clean this device.
Battery Replacement
This device is powered by three (3) 1.5 V (AAA) batteries. When the low bat-
tery symbol appears, replace the batteries immediately, as explained below.
- Switch the meter off and remove the rear battery compartment cover.
- Replace the batteries, observing correct polarity. Always use batteries of the same type.
- Secure the battery compartment before use.
Do not dispose of used batteries or rechargeable batteries in house-hold waste.
Specifications
General Specifications
Display | 4 digit (9999) backlit multifunction LCD |
---|---|
Over range indication | OL is displayed when air velocity or air temperature |
measurements exceed the specified measurement range
Low battery indication| Battery symbol appears when batteries are low
Reading update rate| Two readings per second
Sensor types| Magnetic induction wind speed sensor and NTC (nega- tive
temperature coefficient) sensor
Meter power| Three (3) 1.5 V (AAA) batteries
Dimensions| 6.4 x 2.2 x 1.1 in. (163 x 55 x 28 mm)
Weight| 4.2 oz. (118 g)
Measurement Specifications
Accuracy specifications apply for the following conditions: Temperature:
73.4℉ ± 9℉ (23℃ ± 5℃); Relative Humidity: ≦ 80 %
Air Velocity ranges | Resolution | Accuracy (% of reading) |
---|
1.5 to 30 m/s (meters per second)
5.4 to 108 km/h (kilometres per hour)
2.9 to 58 knots
3.3 to 67 mph (miles per hour)
295.2 to 5905 ft/min (feet per minute) 1 to 12 Beaufort scale (bft)
| 0.1 m/s
0.1 km/h
0.1 knots
0.1 mph
0.1 ft/min* 1 bft
*up to 999.9
| ± (5% + 0.5 digits) m/s
± (5% + 15 digits) km/h
± (5% + 10 digits) knots
± (5% + 10 digits) mph
± (5% + 180 digits) ft/min
± 1 bft
Note: m/s is the standard unit. All other units are calculated from the m/s
value.
Air Temperature range| Resolution| Accuracy
14 to 122℉ (-10 to 50℃)| 0.2℉ (0.1℃)| ± 4℉ (± 2℃)
Environmental Specifications
For indoor use only
Altitude | 6562 ft. (2000 m) maximum |
---|---|
Pollution degree | 2 |
Operating conditions | 32 to 104℉ (0 to 40℃); ≦ 80% RH |
Storage conditions | -4 to 140℉ (-20 to 60℃); ≦ 75% RH |
Drop-proof rating | 3.3 ft. (1 m) |
Connectivity Specifications
Connectivity | Bluetooth (with ExView app) |
---|---|
ExView app compatibility | iOS 13.0 and Android 9.0 or higher |
Transmission distance | Up to 295.3 ft. (90 m) with no line-of-sight |
obstruction
Two-year Warranty
FLIR Systems, Inc. warrants this Extech brand instrument to be free of defects in parts and workmanship for two years from date of shipment (a six-month limited warranty applies to sensors and cables). To view the full war-ranty text please visit: http://www.extech.com/support/warranties.
Calibration and Repair Services
FLIR Systems, Inc. offers calibration and repair services for the Extech brand
products we sell. We offer NIST traceable calibration for most of our
products. Contact us for information on calibration and repair availability,
refer to the contact information below. Annual calibrations should be
performed to verify meter performance and accuracy. Product specifications are
subject to change without notice. Please visit our website for the most up-to-
date prod-uct information: www.extech.com.
Contact Customer Support
Customer Support Telephone List: https://support.flir.com/contact
Calibration, Repair, and Returns e-mail:
repair@extech.com
Technical Support: https://support.flir.com
Website
http://www.flir.com
Customer support
http://support.flir.com
Copyright
© 2021, FLIR Systems, Inc. All rights reserved worldwide.
Disclaimer
Specifications subject to change without further notice. Models and
accessories subject to regional market considerations. License procedures may
apply. Products described herein may be subject to US Export Regulations.
Please refer to exportquestions@flir.com with any questions.
- Publ. No.: NAS100075
- Release: AA
- Commit: 78827
- Head: 78827
- Language: en-US
- Modified: 2021-08-23
- Formatted: 2021-08-23
References
- support.flir.com
- Extech is now on FLIR.com | Teledyne FLIR
- Thermal Imaging, Night Vision and Infrared Camera Systems | Teledyne FLIR
- support.flir.com
- support.flir.com/contact
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>