TECAI HEPAIR 2000 Suction Equipment User Manual

June 13, 2024
TECAI

TECAI HEPAIR 2000 Suction Equipment

Product Information

The suction equipment is a quality product developed by TEINNOVA. It has been manufactured using modern procedures and measures to ensure high quality and performance. The equipment is designed to provide efficient suction capabilities for various applications.

Product Usage Instructions

  1. Before starting the machine, carefully read the usage instructions provided in this manual.
  2. Ensure that you have safety glasses on to protect your eyes from potential dust sprays.
  3. Securely fasten the HEPAIR 2000 during transportation by activating the Wheel block.
  4. Allow sufficient space at the rear of the machine for proper evacuation of air from the turbine’s air vent.

Always refer to this manual for any queries or concerns regarding the usage of the suction equipment. If you have any questions, please contact your distributor or TEINNOVA directly for assistance.

Dear client:
Many thanks for having placed your trust in a quality product from TEINNOVA. This product has been developed with modern manufacturing procedures and a range of measures in order to guarantee quality. We endeavor to do everything possible so that you are satisfied with this product and can work with it without any problems. If you have any questions about this product, please contact your distributor or contact our company directly.
Before starting the machine, carefully read the usage instructions for your equipment. Consider this manual as part of the machine and always have it to hand for future queries.

Training services
Our training services have been designed to support our clients in achieving their objectives and together we develop training programmes that suit their strategy. We offer the possibility of providing companies with specific training for using our equipment and training their operatives so that they can perform the best service and thus contribute to the success of their end clients. This includes aspects such as knowing how to draft a good and objective budget, responding to specific problems that might arise or offering a more professional and efficient service.

Technical service
Thanks to manufacturing the cleaning equipment ourselves we can control the quality and the performance of each machine we manufacture at all times. This has allowed us to have very low repair rates which have always been resolved by our own Technical Assistance Service in very short time frames. The service is managed by the same human team as the factory.
We have every type of replacement available for your equipment as well as related accessories.
teinnovacleaning.com
941445056941445056
his instruction manual is protected by copyright. We reserve all rights, especially the right to produce, translate and create using electronic systems.

symbols

All of the graphic symbols shown in this manual as well as those indicated on the equipment itself are explained in this section. It is important to read the text relating to these symbols with special care as it concerns personal and equipment safety.

DANGER!
This symbol warns of a potentially dangerous situation that could cause serious injuries or even death if the indicated instructions are not followed appropriately. Ensure that you read all the instructions described in the “Safety information” section.
WARNING!
This symbol warns of a potentially dangerous situation that could either cause mild or moderate injuries or damage to property, causing personal injuries, if the indicated instructions are not followed appropriately.
CAUTION!
This symbol warns of a situation that could cause damage to property without causing personal injuries if the indicated instructions are not followed appropriately.
IMPORTANT NOTE!
This symbol warns of information relating to the optimal use of the equipment in order to avoid possible handling errors.

safety warnings

  • It is obligatory to use safety glasses to avoid potential dust sprays from reaching the eyes of the operator.
  • Adequately secure your HEPAIR 2000 and activate the Wheel block during its transportation by vehicle.
  • The rear of the machine has the turbine’s air vent, allow sufficient space for the correct evacuation of air.
  • Do not vacuum liquids or aqueous matter with the machine, only dust-related dirt can be vacuumed.
  • Do not vacuum explosive compounds, easily flammable dust or gases, aggressive or organic substan-ces. Do not use the equipment in explosive environments.
  • Do not use the machine without filters.
  • In the event of obstruction in the aspiration hose or in any part of the machine, turn it off immediately.
  • Be sure to place your HEPAIR 2000 on a flat and stable surface. Block the wheel brakes to ensure the machine remains stable while working.
  • People operating the HEPAIR 2000 machine must be adequately trained.
  • Do not open the control panel of your HEPAIR 2000 aspiration equipment. In the event of a break-down, contact the TEINNOVA Technical Assistance Service on telephone +34 941 44 50 56.

intended conditions of use

The HEPAIR 2000 machine has been designed and manufactured for aspiration in air conditioning ducts, and should not be employed for any other type of use. It has a 5 metre hose which with telescopic supports can adapt to different duct heights. It has three filtration stages. G4 FILTER – PREFILTER M5 – MAIN FILTER F9 This equipment complies with the requisites outlined in STANDARD UNE 100012:2005 “Cleaning air conditioning systems”.

  • Any other use is completely prohibited without written authorization from the manufacturer.
  • The machine management is allowed only to authorized and properly trained personnel, or at least provided with sufficient technical expertise.

TECAI -HEPAIR -2000 -Suction -Equipment -fig \(1\)

get to know your

Components:

  1.  G4 Filter
  2. M5 Pre filter
  3. F9 Main filter
  4. Noise indicator
  5.  Time meter
  6. Power supply
  7. Wheel brake
  8. Wheels
  9.  Switch ON/OFF
  10. Transport handle
  11. Lateral connection for aspiration hose
  12. Connection for aspiration hose
  13. Maintenance cover
  14. Cover tension lock

TECAI -HEPAIR -2000 -Suction -Equipment -fig \(2\)

accessories and related equipment

Optional accessories:

Duct adaptation module
Special module to accommodate both rectangular and circular ducts. It comes with a flexible PVC suction hose used to connect your HEPAIR the duct to be cleaned.
Cod. AC3101308 Pre-filter G4
Special filter for efficient and quality work with your HEPAIR 2000 (10 pieces).
Cod. AC3101305 Bag filter M5
Special filter for efficient and quality work with your HEPAIR 2000.
Cod. AC3101306 HEPA absolute filter H13
Special filter for efficient and quality work with your HEPAIR 2000.
Cod. AC3101309 Extension prop
Extension prop from which the module will support aspiration conduit (2 Units).
Cod. AC3101303

operating instructions

Steps to install the IFOAM correctly:

  1. Placing your HEPAIR 2000:
    Put your HEPAIR 2000 on a flat, stable surface. Put the machine near a power outlet. Once the machine at an optimal site for job performance brakes lock the front wheels so that the machine is stable. TECAI -HEPAIR -2000 -Suction
-Equipment -fig \(8\)

  2. Suction hose connection to the adaptation module:
    The connection is via a hose clamp subject to the module surfa-ce as shown in the figure.

  3. Adaptation module placement through:
    Placing the adaptation module to the conduit with two struts as shown in the figure.

  4. Suction hose connection to HEPAIR 2000:
    The connection is pressurized by fitting the edges of the hose in the suction connection of the machine at the top as shown in the figure.

  5. Connecting to mains electricity:
    The connection will be made by means of an electrical conn-nection cable that comes with the machine. This cable features a mains electricity connector and an electrical supply connector (blue) especially for the machine. Connect the cable to the mains electricity and then connect it to your HEPAIR. The connection made by turning the blue connector to the right. TECAI -HEPAIR
-2000 -Suction -Equipment -fig \(12\)

  6. Turning on your HEPAIR:
    To turn on the machine must press the power switch ON / OFF as shown in the figure.

    • NOT turn on your HEPAIR filter if the cap is not properly closed.
    • If the filters the buzzer warn saturate it. They must stop the machine and unplug it before opening the cover of the filters. Once clean will again be put in the machine and you can return to work.
  7. Turning off your HEPAIR:
    To turn off the machine must press the power switch ON / OFF as shown in the figure.

Disconnect the machine from the mains via the power cable and then disconnect it from its HEPAIR. Disconnection is carried out with a clockwise rotation of the blue connector as shown in the figure.

transport

The machine has been designed to be able to transport it in a small van. Your HEPAIR 2000 has lateral handles for its handling and transportation The machine can only be transported in its working position (vertical). The machine must be firmly secured to the vehicle’s chassis in order to avoid impacts and sliding during its transportation. Placing the machine on a transport pallet or something similar is advised against. It is essential that the machine is rested on a completely flat and horizontal surface. The machine should never be placed in a horizontal position for transporting it. This would cause significant damage in the machine and consequently it would not function correctly.

  • The machine should never be placed in a horizontal position for transporting it. This would cause significant damage in the machine and consequently it would not function correctly.

maintenance and care

Keep the machine as clean as possible. Keep the equipment somewhere that is protected from weather effects. Replace or clean the filters after prolonged use. It is advisable to change the filters every 1000 hours of service. Clean the machine after each job in order to maintain it in perfect condition.

  • Put the lid of the machine if it is not going to be used for a time as well as during transport.
  • In the event of an acoustic signal, check the level of filter saturation.

Maintenance:
Changing filters:
If the filters are saturated and need to be replaced or it shall proceed in the manner shown acontinuación provided with the machine switched off and unplugged. Turn off the machine by pressing the power switch ON / OFF as shown in the figure.

TECAI -HEPAIR -2000 -Suction -Equipment -fig \(16\)

Disconnect the machine from the mains via the power cable and then disconnect it from its HEPAIR. Disconnection is carried out with a clockwise rotation of the blue connector as shown in figure.

It open the lid of filters shown in figure.

TECAI -HEPAIR -2000 -Suction -Equipment -fig \(18\)

Remove the filter behavior as shown in Fig. If it is not enough to clean it should be replaced with new ones. Poor filter will cause a rise in electricity consumption of your machine and will be a decrease in efficiency.

  • No filters support in the area of the board, because if it is dirty seal will be lost to re-position and therefore decrease the efficiency of your HEPAIR aspiration.

TECAI -HEPAIR -2000 -Suction -Equipment -fig \(20\)

Once cleaned or replaced the filters were placed back into position and close the filter cover shown in figure.

Replacement parts:
TEINNOVA has replacements for all parts of the machine as well as for consumables for all the maintenance tasks mentioned in this manual. In the event of needing any part or consumable, get in touch with TEINNOVA’s Customer Service Department on telephone number: +34 941 44 50 56.

waste management

  • The materials used in the packaging are recyclable. Do not dispose of the packaging in household waste, but hand it in at official collection points for recycling.
  • Do not dispose of electrical equipment in the trash! We recommend that electrical tools and accessories are subjected to an environmentally friendly recovery process. Please dispose of the materials in the appropriate container or go to your local collection point.

Directive 2012/19/EU of 4 July 2012 on waste electrical and electronic equipment (WEEE).

technical specifications

HEPAIR 2000 Features
220V / 50Hz 110V / 60Hz
Maximum vacuum volume 2000 m3/h // 1177,2 cfm
Maximum depression 2500 Pa // 0,36 psi
Work point 1600 m3/h a 1800 Pa

941,7 cfm a 0,26 psi
1 filtration level| Coarse filter G4
2 filtration level| Prefilter M5
3 filtration level| Main filter HEPA H13
Separation degree| >99%
Power| 880 W
Current consumption| 4 A| 8A
Noise level| 72 dB
Dimensions| 611 x 590 x 943 mm
24 x 23 x 37 inches
Weight| 80 kg // 176,37 lb

TECAI -HEPAIR -2000 -Suction -Equipment -fig \(22\)

conditions of the guarantee

  1. “TEINNOVA” guarantees its products for a period of 15 days as regards aesthetic defects or faults which are noticeable with the naked eye. In terms of all other manufacturing defects and faults in the products, the guarantee is of 1 year. The “Buyer” must notify “TEINNOVA” of the existence of any defects as soon as they are observed and in any case within a maximum deadline of 5 days from when they become apparent. Notification thereof outside of said deadline shall lead to the non-application of the guarantee. “TEINNOVA” reserves the right to request that the products be sent to the factory or the closest official Technical Support Service for their due inspection and the delivery costs are payable by the “Buyer”. Said costs shall be reimbursed if the product is proven to be effectively non-conforming. “TEINNOVA” will pick up and send the products to the factory or to the nearest official Technical Assistance Service for proper inspection. At that time, it will be determined whether the warranty will apply or it is within the warranty exclusions. If the guarantee is applicable, the transport, both collection at the customer’s facilities and return of the product, will be borne by TEINNOVA. If it is excluded from guarantee (point 2), the transport, both collection at the customer’s facilities and return of the product, will be borne by the customer.
    “TEINNOVA” reserves the right to overrule the application of the guarantee when there is no evidence of the product’s non-conformity and it shall not apply said guarantee until coverage has been expressly proven. In the case that the product is covered, “TEINNOVA” can replace it or determine the necessary repair method. All repair works that are carried out under the product guarantee must be carried out in “TEINNOVA” facilities or in those of the party it designates. The guarantee covers the materials and labour required to repair or replace the parts or elements considered as defective from origin. The maximum guaranteed amount or value shall be the maximum price of the sale of the product to the “Buyer”. Any claims made under the coverage of the guarantee shall not grant the right to delay and/or withhold payment of the corresponding invoice and/or any other pending invoices.

  2. Guarantee Exclusions: the following are excluded from the guarantee: actions, alterations or manipulations of the product that are carried out without the prior express authorization of the “Seller”; indirect and/or consequential damage; damage caused by negligence, by improper use or by usage that does not conform to the instructions and intentional damage; faults due to adaptations made to the products or the use of parts that were not previously and expressly certified or authorized by the Seller; costs for detection of the fault; costs for collection or replacement (the latter two are unless the non-conformity is proven and within the limits established in section 1).

TECAI INNOVA S.L.
C/ Las Balsas 16-B, Pol. Ind. Cantabria. 26009 LOGROÑO (La Rioja), España.
TEINNOVA reserves the right to make changes to the equipment without giving prior notice.

declaration of agreement “CE”

MODEL: HEPAIR 2000
SERIAL NUMBER: TC31302010000 – TC31302019999
MANUFACTURER INFORMATION:
Manufacturer name: TECAI INNOVA S.L.
Telephone number: +34 941 44 50 56
Fax: +34 941 25 24 71
Web: www.teinnova.net
TECAI INNOVA, SL, under its sole responsibility, certifies that the machine model described above complies with all the essential requirements of the following directives:

  • Machinery directive 2006/42/CE
  • Directive 2014/30/EU on electromagnetic compatibility and its amendments.
  • Directive 2014/35/EU on the sale of electrical equipment.

Technical Director
ARMANDO SÁENZ ANGULO
Pol. Ind. Cantabria, C/Las Balsas 16
26009 Logroño (La Rioja)

References