vexen VSOU-1 Twilight Switch Instructions

June 13, 2024
vexen

INSTRUCTIONS
VSOU-1

TWILIGHT SWITCH

Sensor for VSOU-1 is external and is connected to terminals IN. Sensor is installable to panel (by screw-able transparent cover) to opening with diameter 6 mm. A part of the sensor is a plastic holder for placing into the wall or to another place. Length of a line connector to the sensor cannot be more than 50m. Doublecure cable can be used as wire diameter min. 2×0.35 mm2 and max. 2×2.5 mm2 . It is possible to use photoresistor, which changes resistance in accordance with ambient illumination, as a sensor. Protection degree is IP56.

To keep this protection:

  • photoresistor cover must be sealed by a rubber circle (part of the sensor) cable must be of round shape the opening must be tight to the used cable
  • toleration +/-33%

WARNING! Device is constructed for connection in 1-phase AC 230 V or AC/DC 12- 240 V main alternating current voltage and must be installed according to norms valid in the state of application. Connection according to the details in  this direction. Installation, connection, setting and servicing should be installed by qualified electrician staffonly, who has learnt these instruction and functions of the device. This device contains protection against overvoltage peaks and disturbances in supply. For correct function of the protection of this device there must be suitable protections of higher degree (A,B,C) installed in front of them. According to standards elimination of disturbances must be ensured. Before installation the main switch must be in position “OFF” and the device should be de-energized. Don´t install the device to sources of excessive electro-magnetic interference. By correct installation ensure ideal air circulation so in case of permanent operation and higher ambient temperature the maximal operating temperature of the device is not exceeded. For installation and setting use screw-drivercca 2 mm. The device is fully-electronic – installation should be
carried out according to this fact. Non-problematic function depends also on the way of transportation, storing and handling. In case of any signs of destruction, deformation, non-function or missing part, don´t install and claim at your seller it is possible to dismount the device after its lifetime, recycle, or store in protective dump.

TECHNICAL PARAMETERS:

Supply:  A1-A2
Supply voltage: AC/DC 12-240 V (AC 50- 60 Hz)
Input: AC 0.7-3 VA/DC 0.5-1.7 W
Supply voltage: AC 230 V/ 50 – 60 Hz
Input (apparent/loss): AC max. 12 VA/ 1.8 W
Supply voltage tolerance: -15%;+10%
Supply indication: green LED
Time delay: 0 – 2 min
Time delay setting: potentiometer
Illumination range 1: 1 – 100 Lx
Illumination range 2: 100 – 50000 Lx

Controlling:
Consumption of control input:| 0.8 – 530 mVA(UNI), 0.8 – 530mVA(AC230V)
Load between S-A2:| YES (UNI,AC 230V )
Max. capacity of cable control:
– without connected glow-lamps| 12 nF (UNI), 12 nF (AC 230V)
– with connected glow-lamps| 9nF (UNI), NO
9nF (AC 230V), max. 4pcs (1pcs-1mA)
Control. terminals:| A1-S
Impulse length:| min. 25 ms/max. unlimited
Reset time:| 150ms
Output:
Number of contacts:| 1x changeover (AgSnO2)
Rated current:| 16A/AC1
Switched capacity:| 4000VA/AC1, 384W DC
Inrush current:| 30A/<3s
Switched voltage:| 250V AC1/24 V DC
Min. switching capacity DC:| 500mW
Output indication:| red LED
Mechanical life:| 3×10⁷
Electrical life (AC1):| 0.7×10⁵
Other information:
Operating temperature:| -20…+55°C
Storage temperature:| -30…+70°C
Electrical strength:| 4kV (supply-output)
Operating position:| any
Mounting:| DIN rail EN 60715
Protection degree:| IP 40 from front panel
Length of connecting wire to sensor:| max.50m (standard wire)
Overvoltage category:| III.
Pollution degree:| 2
Profile of connecting wires:| 2.5 мм²/with sleeve 1.5 мм²
Weight of sensor:| 20 g
Dimensions:| 90 x 17.6 x 64 mm
Weight:| (UNI) – 75 g, (230) -65 g
Standards:| EN 60255-6, EN 61010-1
Relay contact:| 16A

CHARACTERISTIC

  • supply voltage: AC 230 V or AC/DC 12 – 240 V
  • adjustable time dwell to eliminate short term illumination
  • level of illumination adjustable in two ranges: 1 – 100 Lx and 100 – 50000 Lx
  • external input S for “permanent” output switching off (e.g. blocking of output by time switch in fixed night time, when is not eff ective, to flash be switched on)
  • external sensor, suitable for mounting on the wall
  • LED output indication
  • 1-MODULE, DIN rail mounted

DESCRIPTION

vexen VSOU 1 Twilight Switch - DESCRIPTION

DESCRIPTION OF CONTROLLING ELEMENTS /
Description of DIP switch

| Chosen range can be set by trimmer LEVEL (1-100 Lx or 100-50000 Lx).
realignment is possible in whole range
---|---
| Delay in reaction of the device is set by a trimmer. Delay can be set in range 0 – 2 min. Delay is used mainly in places, where sensor can be influenced by another illumination, than the required one.

DESCRIPTION OF DIP SWITCHES

| By switching to position TEST all function are switched off and switching contacts of output relay are switched on. The function TEST is used for testing of right connection of load and for verifi cation of failure (breaking of the bulb)
---|---
| Device sensitivity is devided into two ranges. This is for better sensitivity of setting. In the fi rst range 1 – 100 Lx device reacts to low intensity of surrounding illumination. It is for twilight control.
| In the second range 100 – 50000 Lx device reacts in a wide range of illumination intensity. It is not possible to set twilight sensitivity in this range but it is possible to operate permanent illumination in rooms or to diff er sunny/cloudy. Applicable for controlling of sunshades or controlling of circulating pump for heating by sunlight.

SYMBOL

| | | | | AC1| AC3| AC15| DC1
(24/110/220 V)

---|---|---|---|---|---|---|---|---
LOAD| 200W| 1000W| 750W| 500W| 4000W| 0.9KW| 750VA| 16 A/0.5 A/0.35 A

CONNECTION

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

vexen User Manuals

Related Manuals