phocos AB-PLC Any-Bridge Remote Monitoring and Control Gateway Instruction Manual
- June 4, 2024
- phocos
Table of Contents
Phocos Any-Bridge™ Series
Monitoring & Control Gateway Model AB-PLC
for access to the PhocosLink Cloud
AB-PLC
User and Installation Manual
For further languages see
Introduction
Dear customer, thank you for choosing this quality Phocos product. The Any-
Bridge™ AB-PLC Monitoring & Control Gateway (referred to as “gateway” in this
manual) allows you to connect your Phocos AnyGrid™ PSW-H Series
inverter/charger with MPPT solar charge controller (referred to as “power
device” in this manual) to the internet for access to the PhocosLink Cloud
portal (referred to as “portal” in this manual). This portal enables viewing
and control (functionality enabled by a future over-the-air automatic update,
no user intervention required) of your power device through any internet-
connected device with an internet browser such as a personal computer, tablet
or smartphone. The purchase of this device enables free introductory access to
the PhocosLink Cloud with up to three Any-Grid PSW-H devices for a limited
time, see www.phocos.com for details regarding access
plans.
This manual describes the installation and operation of this unit. Read this
entire document before proceeding with the installation.
Important Safety Information
SAVE THESE INSTRUCTIONS: This manual contains important instructions for the model AB-PLC in the Any-Bridge Series. Read and save this manual for future reference. The following words are used to mark important sections for your safety:
WARNING | Failure to follow instructions could cause physical harm. |
---|
WARNING: It is not necessary to open any covers or access any high- voltage components in the power device for installation. The power device may only be opened by trained electricians.
About the Any-Bridge AB-PLC
A working internet connection is required for the gateway to be able to communicate with the PhocosLink Cloud portal and upload data regularly. However, in case of internet access interruption, data is stored in the gateway until the internet connection is re-established, then this data is seamlessly sent to the portal to fill any data gaps caused by the internet interruption (functionality enabled by a future over-the-air automatic update, no user intervention required).
① MXI interface (unused at this time)
② RS-485 interface (unused at this time)
③ RS-232 interface for Any-Grid PSW-H
④ Power indicator
⑤ Portal connectivity indicator
⑥ Reset button for factory reset
⑦ Ethernet LAN interface
⑧ Wi-Fi / BLE antenna
WARNING: The gateway is designed to be powered by the connected power device. No external power supply is required. Attempting to power the gateway with an external power supply may cause physical harm or damage/destroy the gateway.
Installation
4.1 Requirements
- Photos Any-Bridge AB-PLC monitoring & control gateway
- One to three powered Any-Grid PSW-H power devices with U2 firmware version ≥ 06.18
- Working internet infrastructure (modem/router with active DHCP for automatic IP address issuing) with Ethernet and/or 2.4 GHz 802.11b/g/n Wi-Fi access
- Android™ or iOS device with BLE V4.2 or higher
4.2 Package Contents
Before installation, please inspect the unit. If something inside the package
is missing or damaged, please contact your dealer. Package contents:
- Any-Bridge AB-PLC monitoring & control gateway
- External antenna
- Cable with 8P8C modular connectors at each end
- User and installation manual
4.3 Physical Installation
Lightly screw the included antenna into the antenna connector at position ⑧,
ensuring it is less than hand-tight to avoid damage. Either place the gateway
on a flat surface as pictured in the title image of this manual.
Alternatively, mount the gateway on a vertical wall by using the 4 pcs.
M3-sized (3.5 mm / 0.14 in) screw-holes provided. Once installed, point the
antenna so that it runs parallel to your router antenna or, if in doubt, point
it straight up vertically.
4.4 Setup
For a video to help with the installation visit www.phocos.com/phocoslink-
cloud. Choose any of the power
devices and connect the included cable with 8P8C connectors (any
direction) between the RS-232 port of the power device and the ③ RS-232 port
of the gateway. Ensure the power device is not in standby and that its display
is on. The power
④ and portal connectivity ⑤ indicators will blink several times while the
gateway starts up (see chapter 5 for details). If using wired Ethernet,
connect the Ethernet cable from your router to port ⑦ of the gateway.
Download the latest “PhocosLink Mobile” App from the Google Play™ store or
Apple’s App Store® with an Android™ or iOS device, respectively. Open the app
and allow BLE and location permission (location is not recorded or used by the
app, but access must be permitted for BLE to function). The QR codes left and
right link to the app directly.
|
---|---
https://play.google.com/store/apps/details?id=phocos.com.phocoslinkandroid|
https://apps.apple.com/us/app/phocoslink/id1477129752
In the app, scan for devices with the button at the bottom right and then tap the Any-Bridge™ gateway:
Ensure the connection between the power device and gateway is not greyed out (the power device is shown as connected) and the solid-state relay is shown as “closed” (green). If it is not, go back to the previous screen (arrow at top left) and try again by tapping the Any-Bridge. Then tap “SETUP”. Enter your credentials:
- Wi-Fi Access Point (SSID) and W-Fi password (only shown if no Ethernet cable is plugged in)
- PV system name as it will be shown on the portal
- Your e-mail address serves as your login ID to the cloud then tap “SUBMIT”.
Once submitted, wait for each of the steps to automatically complete with a
(except the “Wi-Fi” steps if using wired Ethernet), this may take a few
minutes, then tap “DONE” when completed and the activation e-mail is
successfully sent.
You will now receive an invitation to the e-mail address you provided with
your access link to the PhocosLink Cloud, select “Accept Invitation”. This
will lead you to the PhocosLink Cloud website to finalize your initial setup.
If you do not receive the e-mail within 5 minutes, check your e-mail spam
folder. If you still did not get the email, go to cloud.phocos.com and select
“Forgot your password?”. Then enter the same e-mail address you used
previously and select “Send reset email”.
The initial setup is now complete, and the gateway automatically sends data to
the PhocosLink Cloud continuously while the internet connection is active as
shown by indicator ⑤. While connected to the gateway with the “PhocosLink
Mobile” app, the 4 green (connected) or grey (disconnected) toggle icons give
you a view of the working state of the gateway at any time while it is running
(example shown with Wi-Fi):
LED Indicators
The gateway is equipped with two LED indicators, the power ④, and the portal connectivity ⑤ indicators. During operation, these indicators have the following meanings:
Power ® | Portal con. | Meaning |
---|---|---|
OFF | n/a | The gateway is not powered. This is normal if the power device is in |
stand-by (display off)
ON| n/a| Gateway is a powered power device communication successful
Slow blink”-| n/a| Gateway is powered and a BLE device is connected
n/a| ON| Connected to portal
n/a| OFF| Disconnected from portal
ON| Slow blink`| Connected to Wi-Fi or Ethernet, but portal connection
unsuccessful
Slow blink| Slow blink| Gateway starting up or power device firmware
incompatible if blinking for >10s
Fast blink| Fast blink| Gateway performing reset
- Slow blink: 0.5s on, 0.5s off.
** Fast blink: 0.1s on, 0.9s off.
Troubleshooting
Problem | What to do |
---|---|
Power indicator ® OFF | The gateway is not powered. Use only the included cable |
for connection between the power device and gateway. Check the cable for
correct seating on both ends. Ensure the power device is running (power device
display on).
Power ® and Portal con. ® indicator blinking slowly > Los| The firmware on the
power device is not compatible with the gateway. Contact your dealer or Phocos
for a firmware update. A standard USB to RS-232 converter and Windows PC is
required for the update.
Power ® indicator ON and Portal
con. ® indicator blinking slowly| If using Wi-Fi, the entered access point
(SSID) or password is incorrect or the access point is not using WPA-PSK2
encryption. To re-enter Wi-Fi credentials, press the reset button © until the
gateway restarts. Then repeat the setup procedure in chapter 4.4.
If using wired Ethernet, make sure the connection is good and that your router
supports DHCP.
Ensure your router is connected to the internet.
Warranty
7.1 Conditions
We warranty this product against defects in materials and workmanship for a
period of 24 months from the date of purchase and will repair or replace any
defective unit when directly returned, postage paid by the customer, to
Phocos. This warranty will be considered void if the unit has suffered any
obvious physical damage or alteration either internally or externally. This
warranty does not cover damage arising from improper use, such as plugging the
unit into unsuitable power sources or attempting to operate products that
require excessive power consumption or use in unsuitable environments. This is
the only warranty the company makes. No other warranties express or implied
including warranties of merchantability and fitness for a particular purpose.
Repair and replacement are your sole remedies and the company shall not be
liable for damages, whether direct, incidental, special or consequential, even
if caused by negligence. Further details about our warranty conditions can be
found at www.phocos.com.
7.2 Liability Exclusion
The manufacturer shall not be liable for damages, especially on the battery,
caused by use other than as intended or as mentioned in the manual or if the
recommendations of the battery manufacturer were neglected. The manufacturer
shall not be liable if there has been service or repair carried out by any
unauthorized person, unusual use wrong installation, or incorrect system
design.
Specifications are subject to change without notice.
Copyright © 2020 – 2021 Phocos AG, All Rights Reserved.
Version: 20210817
Made in China
Phocos AG
Magirus-Deutz-Str. 12
89077 Ulm, Germany
Phone +49 731 9380688-0
Fax +49 731 9380688-50
www.phocos.com
info@phocos.com
ISO 9001
RoHS
Documents / Resources
|
phocos AB-PLC Any-Bridge Remote Monitoring and Control
Gateway
[pdf] Instruction Manual
AB-PLC Any-Bridge Remote Monitoring and Control Gateway, AB-PLC, Any-Bridge
Remote Monitoring and Control Gateway, Remote Monitoring and Control Gateway,
Monitoring and Control Gateway, Control Gateway, Gateway
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>