Haier ES50V-VH3(EU) Electric Water Heater Instruction Manual
- June 13, 2024
- Haier
Table of Contents
Electric Water Heater
Instruction Manual
ES50V-F1(EU), ES80V-F1(EU)
ES100V-F1(EU), ES50V-TF7(EU)
ES80V-TF7(EU), ES50V-VH3(EU)
ES80V-VH3(EU)
Please read this manual carefully before use.
Please keep it properly for future reference.
This product is for home use only and should not be used for industrial or
commercial purposes.
Safety Precautions (Please Read Before Use)
Symbolic Interpretation
| Actions must be prohibited
---|---
| Actions must be performed
| Actions must be attended to
It is necessary to allow disconnection of the appliance from the supply after installation. The disconnection may be achieved by having the plug accessible or by incorporating a switch in the fixed wiring in accordance with the wiring rules.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
The max. inlet water pressure is 0.75MPa, and the min. inlet water pressure is
0.05MPa.
If the water heater is not use for a long time, please cut off the power and
drain the water storage in the water heater.
You can refer to the below part for how the water heater can be drained.
It is strictly forbidden to install the water heater in an environment where
it can freeze. Freeze can cause the container and water pipes to break,
resulting in scalding and leak.
Do not install the water heater in outdoor areas.
Please install the water heater on a solid, sturdy wall.
The appliance is intended to be permanently connected to the water mains and
not connected by a hose-set.
A discharge pipe connected to the pressure-relief device (safety valve) is to
be installed in a continuously downward direction and in a frost-free
environment.
The water may drip from the discharge pipe of the pressure-relief device
(safety valve) and that this pipe must be left open to the atmosphere.
The pressure-relief device ((safety valve) is to be operated regularly to
remove lime deposits and to verify that it is not blocked.
You can refer to the below part for the type or characteristics of the
pressure-relief device (safety valve) and how to connect it, unless it is
incorporated in the appliance.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children shall not play with the appliance.
Do not repair, maintain, dismantle or modify the water heater without
professional maintenance persons.
Use independent outlets and make them reliably earthed.
If you notice any abnormality or smell burnt odor, please immediately cut off
the powerand contact the service center.
Be careful not to be scalded by hot water.
- Do not touch the valves and pipes that supply hot water.
- Please test the water temperature with your hand before use. When the water is at the right temperature, then use it.
In order to avoid a hazard due to inadvertent resetting of the thermal cut-
out, this appliance must not be supplied through an external switching device,
such as a timer, or connected to a circuit that is regularly switched on and
off by the utility.
The instructions for appliances connected to the water mains by detachable
hose-sets shall state that the new hose-sets supplied with the appliance are
to be used and that old hose-sets should not be reused.
Children should be supervised to ensure that they do not play with the
appliance.
This appliance can be used by children aged from 3 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
It is strictly forbidden to use wet hands to plug and unplug the power supply.
Check the electric meter, whether the diameter of wire is in line with the
rated current of the water heater, if necessary, invite a qualified
electrician to check the wiring.
Do not use the hot water from the water heater directly as drinking water or
for similar purposes.
Do not sprinkle water or spray steam on the main unit of the water heater.
Do not sprinkle water or spray steam on the main unit of the water heater.
External Dimensions
External Dimensions
A Hot water outlet
B Cold water inlet
C Inner liner
D Heating tube| E Temperature tube
F Magnesium rod
G Wall bracket
---|---
Model| a1(mm)| b1(mm)| c1(mm)| d1(mm)| e1(mm)| f1(mm)| g1(mm)
---|---|---|---|---|---|---|---
ES50V-F1(EU)| 530| 305| 720| 350| 170| 362| /
ES80V-F1(EU)| 530| 305| 1046| 350| 170| 635| /
ES100V-F1(EU)| 530| 305| 1265| 350| 170| 851| /
ES50V-1F7(EU)| 530| 320| 745| 100| 360| 297| 194
ES80V-1F7(EU)| 530| 320| 1070| 100| 360| 622| 194
ES50V-VH3(EU)| 410| 421| 685| 100| 190-270| 200| /
ES80V-VH3(EU)| 410| 421| 995| 100| 190-270| 510| /
Note: The allowable error range of the above parameters (dimensions) is ±10%.
Technology Datas
All models| Rated Voltage| Rated Frequency| Rated Pressure| Rated Temperature|
Waterproof Level
---|---|---|---|---|---
220-240W| 50Hz| 0.80MPa| 75°C| IPX4
Model | Rated Power | Net Weight | Rated Capacity |
---|---|---|---|
ES50V-F1(EU) | 3000W | 25kg | 47L |
ES80V-F1(EU) | 3000W | 33kg | 77L |
ES100V-F1(EU) | 3000W | 41kg | 97L |
ES50V-TF7(EU) | 3000W | 25kg | 46L |
ES80V-TF7(EU) | 3000W | 34kg | 74L |
ES50V-VH3(EU) | 1500W | 18kg | 47L |
ES80V-VH3(EU) | 1500W | 26kg | 75L |
Electrical Schematic
Packing List
Quantity/Model| Electric Water
Heater
(unit)| Safety Valve
(unit)| Expansion
Bolt
(unit)| Instruction
Manual
(unit)| Wall-mounting
frame
(unit)| Expansion
hook
(unit)
---|---|---|---|---|---|---
F1 Serie| 1| 1| 4| 1| 2| /
TF7 Serie| 1| 1| /| 1| /| 2
VH3 Serie| 1| 1| /| 1| /| 2
Installations
Installations Cautions
- When installing the water heater, it should leave a certain amount of space (at least 300mm) to facilitate future maintenance. If the water heater is embedded in the gusset plate during installation, the gusset plate near the maintenance cover side should be movable to facilitate disassembling the maintenance cover during maintenance.
- It should ensure that the inlet pressure of tap water is not less than 0.05MPa and the maximum pressure does not exceed 0.75MPa.
- Electric water heater should be installed indoors, where the ambient temperature is above 0°C. The pipeline should be centrally arranged. The hot water outlet should not be too far from the use place of hot water. If it exceeds eight meters, the hot water pipeline should be insulated to reduce the heat loss.
- The wall where the water heater is hung should be sturdy and secure to withstand four times the weight of the water heater after filling with water. If it is a non-bearing wall or hollow brick wall, it is necessary to take appropriate protective measures, add brackets, use crossing screws, and install back boards.
- The installation location of the electric water heater should be selected a place that is convenient to use, maintain and have a floor drain. If the water tank or water pipe leaks, it will not cause damage to nearby or lower level facilities. The installation position try to avoid installing on the toilet, bathtub, washbasin and door frame. So that it does not create a feeling of overwhelming or insecurity for the user.
- Do not reverse the inlet and outlet pipes. The safety valve should be installed in the designated position and should not be altered privately. The pressure relief hole of safety valve should be kept in contact with atmosphere. Do not block it.
- For security, water heaters should use independent sockets (multifunctional sockets are prohibited) and be reliably earthed. And the quality of the socket should be in line with local national standards. It is strictly forbidden to use the water heater without reliable earthed.
- The power outlet of the water heater should be placed in a dry place where water cannot shower, so as not to affect the normal work of the machine (preferably with a waterproof box).
- Use an electro probe to measure whether the live wire and neutral wire are connected in reverse. After confirming that the machine has been filled with water, the joints do not leak and the power supply meets the requirements, then it can be heated by electricity.
- For avoiding the danger of accidental reset of the over-temperature thermostat, the water heater must not be powered by external switching devices such as timers. It shall not be connected to a circuit that is frequently switched on and off through other settings.
- In order to prevent the occurrence of accidents, the accessories provided by our company must be installed and must not be replaced or substituted by yourself. If the accessories are damaged, it must be notified to our Maintenance Department for repair and replacement with the accessories provided by our company. If the above matters are not complied with, we will not be responsible for any direct or indirect loss caused by the accident.
Installation Methods
Figure 1 Installation Schematic – Vertical Installation (F1/TF7/VH3 Series)
Figure 4 Installation Schematic – Horizontal Installation(for TF7 Series only)
It must be installed according to the schematic
- It must be installed by the installer belonging to the After-sales Service Department of our company or by its designated installer. For the installation of the water heater by personnel not recognized by our company or the use of self-provided installation materials, which results in the consequences, including but not limited to pipeline leakage, crash, poor installation affecting the normal operation and performance of the water heater, and adverse effects or damage to the body of the water heater. The company will not be responsible for any losses incurred as a result.
- The water heater uses wall-mounted installation.
For the F1 Serie, the installation method is as follows:
- Refer to Figure 1 of the Installation Schematic, and drill four holes in the wall using an percussion drill to match the accessory expansion hook according to the dimensions shown in Figure 2 and the table below.
Model| ES50V-F1(EU)| ES80V-F1(EU)| ES100V-F1(EU)
---|---|---|---
a| 170 mm| 170 mm| 170 mm
b| 88 mm| 88 mm| 88 mm
c| 362 mm| 635 mm| 851 mm - Insert the expansion bolts into the wall-mounting frame first, then fix them together in the wall holes, and finally hang the water heater onto the wall-mounting frame.
- Install the safety valve and other accessories with reference to the “Installation of Safety Valve” (for installation reference only). Be careful to add thread seal tape seal to prevent water leakage.
For TF7/VH3 Series, the vertical installation method is as follows:
- Refer to Figure 1 of the Installation Schematic, and drill two holes in the wall using an percussion drill to match the accessory expansion hook according to the dimensions shown in Figure 3.
- Insert the expansion hook into the wall hole and fix it, then hang the water heater onto the hook.
- Install the safety valve and other accessories with reference to the “Installation of Safety Valve” (for installation reference only). Be careful to add thread seal tape seal to prevent water leakage.
For TF7 Serie, the horizontal installation method is as follows:
-
Refer to Figure 4 of the Installation Schematic, and drill two holes in the wall with an percussion drill to match the accessory expansion hook according to the dimensions shown
in Figure 5. -
Insert the expansion hook into the wall hole and fix it, then hang the water heater onto the hook.
-
Install the safety valve and other accessories with reference to the “Installation of Safety Valve” (for installation reference only). Be careful to add thread seal tape seal to prevent
water leakage.
- In order to facilitate the installation and disassembly of the water heater, it is recommended that the water heater inlet and outlet pipes are installed at the appropriate location with G1/2 loose joints respectively. Determine the location of the water supply. Connect the water inlet pipe and the tap pipe to the water place respectively. Fill the inner tank with water, check whether the water line is leaking. If there is a leak, it needs to be reconnected.
Warning: It is important to make sure that the hooks on the back of the machine (F1 Serie) or the wall bracket (TF7/VH3 Series) are securely hung on the wall-mounting frame (F1 Serie) or expansion hook (TF7/VH3 Series) before releasing the hands to prevent the water heater from falling and causing personal injury or property damage.
Installation of Safety Valve
-
Install the safety valve (its connection is G1/2) with a rated pressure of 0.80MPa in the direction of the arrow on the safety valve (arrow pointing to the water heater) to the inlet pipe. When the water heater is heated by electricity, the water inside the tank is heated and expands. In order to reduce the water pressure inside the tank, a small amount of water droplets will flow from the pressure relief hole of the safety valve. The pressure relief hole should be kept open to the atmosphere and should not be blocked.
-
The pressure relief hole of the safety valve can be connected to the drain pipe. The installation method of the drain pipe of the safety valve is as follows: Screw the one end of the drain pipe to the pressure relief hole of the safety valve. The drain pipe connected to the safety valve should be kept inclined installed in a frost-free environment in a continuous downward way, and the water overflowing from the drain pipe should drain into the floor drain.
Note: Drain pipes are sold separately.
Operations
Operations
After installation, because of the inner tank without water, you must open the
inlet valve of tap water and outlet of water heater for the first time. The
water mixing valve must be adjusted to the maximum hot water gear, and the
water outlet shall be closed after the nozzle or other water outlets
continuously discharge water (it means that the water in the container is full
at this time). Check and turn on the power supply when there is no water
leakage at each interface.
After the water heater is powered on for the first time and the display screen
is fully displayed for 1s, it enters the state before turning on the power.
Introduction of Control Panel
Button Introduction | Icon Introduction |
---|---|
Enter the bath separately mode/ Choose the number of bath separately |
Display icon of the number of bath separately
| Enter single tank mode| | Heating icon
| Enter double tanks mode| All| Double tanks mode icon
| BPS bacteriostatic mode button| Half| Single tank mode icon
| Power-on/Power-off| | Set temperature /actual temperature icon
| | | Bacteriostatic function icon
Button Introduction | Icon Introduction |
---|---|
BPS bacteriostatic mode button | |
MAX mode button | |
ECO mode button | |
Set temperature button |
actual temperature icon
| Power-on/ Power off| | Bacteriostatic function icon
Button Introduction | Icon Introduction |
---|---|
Function select button | |
Set temperature button | |
Power-on/Power-off | |
Power-on
- Plug in the power supply, and the display screen will be fully displayed for 1s, entering the state before power-off.
- Press the « » button to power on.
Single / Double Tank(s) Mode (F1 Serie)
Press the “1.5kW” button, and then the icon “Half” will be illumed. After the
default maximum heating temperature 75ºC. flashing for 2s, the actual water
temperature will be displayed. And the machine uses 1500W power to heat the
water in the left tank.
Press the “3kW” button, and the icon “All” will be illumed. And the machine
uses 3000W power to heat the water in both tanks at the same time.
Bath Separately Mode (F1 Serie)
-
Press the “Smart” button to choose the number of bath separately at one time. The number of bath separately at one time will be switched circularly between 1, 2 and 3.
Digital 1 is illumed: It is suitable for 1 person to take a bath.
Digital 2 is illumed: It is suitable for 2 persons to take a bath.
Digital 3 is illumed: It is suitable for 3 persons to take a bath. -
The machine will automatically complete the heating according to the number of bathing people you choose.
50L water can be set to bath for 1 person and 2 persons.
80L / 100L water can be set to bath for 1 person, 2 persons and 3 persons.
BPS Bacteriostatic Mode (F1/TF7/VH3 Series)
Press the “BPS” / « » button, entering the bacteriostatic mode and illuming
the corresponding icon « » /« » /« BPS- ». After the default maximum heating
temperature flashes for a few seconds (80°C for F1 series and 75°C for TF7/VH3
serie), the actual water temperature will be displayed. When the « » /« » /«
BPS- ». extinguishs, it indicates that the bacteriostatic function is
completed, and the machine will automatically exit the BPS bacteriostatic mode
and return to the normal mode.
Press « » button again to switch to ECO-BPS-Instant heating in turn(VH3
Serie).
ECO Mode (TF7/VH3 Series)
Press the “ECO” / « » button in the state of power-on, entering the ECO mode
and the corresponding icon « » / « ECO- » are illumed.
In this mode, the water heater will automatically memorize and analyze user’s
habits of using water, realize intelligent operation, to meet user’s water
demand and save electric energy to the most extent.
Press “ECO” button again to exit ECO mode and return to normal mode.(TF7
Serie)
Press « » button again to switch to ECO-BPS-Instant heating in turn(VH3
Serie).
This function can memorize when power off, but it will reopen the memory of
user’s habits of using water.
MAX Mode ( TF7 Serie)
Press the “MAX” button in the state of power-on, entering the MAX mode and
illuming the corresponding icon « ». In this state, the two tanks are heated
to the setting temperature, and the setting temperature range is 35-75°C.
After heating, the machine will automatically exit the MAX mode and return to
the normal mode.
In this mode, the double tanks are heated simultaneously, which can meet the
user’s demand of using water rapidly.
Normal Mode ( TF7/VH3 Series)
When the user does not choose the above modes, the machine will enter the
normal mode.
In this mode, the user can adjust the setting temperature according to the
demand, and the range of setting temperature is 35-75°C. The function of heat
retention is carried out after
heating.
Temperature Setting ( TF7 Serie)
In the MAX mode and ECO mode, press the “SET” button to adjust the setting
temperature.
Each time the “SET” button is pressed, the setting temperature will increase
by 5°C. The adjustment range of setting temperature is 35ºC-75°C. When
pressing the “SET” button to set the temperature, the current setting
temperature flashes first, and then press the “SET” button to change the
temperature. No operation within 6s or pressing other buttons except the « »
and “SET” button indicate that the setting temperature is confirmed, and then
the actual temperature is displayed.
Temperature Setting ( VH3 Serie)
In the normal mode, press “+”/“-” button to adjust the setting temperature,
press “+”/“-” button for one time, « » flashes the current setting temperature
for 6 times, if press “+”/“-” button for one time every time, then the setting
temperature is to increase/decrease by 5°C.
Quantity of remaining hot water ( VH3 Serie)
Under the status of switching on, the quantity of current remaining hot water
can be monitored through the icon « ».
Power-off
After bathing, press the « » button to power it off.
Tip: When the water heater works in the double tanks mode, affected by
the power difference between the heating tubes of the two tanks and other
factors, it is normal that the right tank is still heating when the display
screen displays 75 °C (F1/ TF7 Series).
Precautions for Use
- Do not turn on the power supply before the water heater is filled with water, protecting the machine from damage.
- Adjust the water temperature to the appropriate temperature before use, preventing scalding.
- When there is enough hot water, turn down the set temperature as much as possible, which can reduce heat loss, high-temperature corrosion and scaling, and prolong the service life of the water heater.
- Please do not put gasoline and other inflammables near the water heater, or which may cause fire and other accidents.
Cleaning and Maintenance
Warning: This water heater should only be repaired and maintained by
qualified service personnel.
Improper methods may cause serious injury accidents or property losses.
Be sure to unplug the power plug before cleaning and maintaining the water
heater.
Wipe gently with a damp cloth dipped in a small amount of neutral detergent.
Do not use gasoline or other solutions. Finally, dry it with a dry cloth to
keep the water heater dry. Be careful not to scrub with cleaners containing
abrasives (including toothpaste), acids, chemical solvents (including alcohol)
or polishes.
To keep the water heater working efficiently, the heating pipe and inner tank
should be cleaned every three years. When cleaning, do not damage the
protective layer on the outside of the heating pipe and the surface of the
inner tank. The warranty period of the inner tank is 7 years, and the anode
needs to be inspected once a year from the second year.
When cleaning, close the water inlet valve, open the water outlet valve,
remove the safety valve at the cold water inlet, drain the water in the water
tank, and then open the water inlet valve to wash repeatedly for several
minutes until the clean water discharged from water tank.
Check the safety valve once a month: Pull the small handle of the safety
valve. If there is water flowing out, it indicates that the safety valve has
worked normally. If there is no water flowing out, please contact Haier After-
sales Service Department for repair or replacement.
The safety inspection, removing the scale in heating pipe in time and
replacing the magnesium rod shall be carried out by professionals regularly.
Attention:
- If you do not use the water heater for a long time, please close the tap water valve and open the hot water valve of the water heater to the maximum hot water gear. At the time, please be careful not to be scalded by hot water. And then remove the safety valve, let the water flow out of the inner tank.
- When re-using, to avoid injury accidents, it is recommended to open the hot water valve before opening the power switch of the water heater, discharging the gas that may exist in the pipe line from the pipe line. At the time, smoking or other open flames are not allowed near the opened valve. Meanwhile, carefully check whether all parts of the water heater are in good condition, and confirm that the inner tank is filled with water. Then, the water heater can be put into use.
Transportation and Storage
Products must be transported and stored in accordance with the handling marks
indicated on the original packaging.
Be careful when handling and transporting.
When transportation and storage, it is must ensure that the product is
protected from atmospheric precipitation and mechanical damage.
Product Disposal
If the electric water heater cannot be used and you want to discard it, you
must dispose it correctly in order not to damage the environment. For more
information, please contact the local service department. If the water heater
is used for scrapping, cut the power line as close to the shell as possible so
that the water heater can no longer be used. The electric water heater is
designed and manufactured in such a way that you can easily handle it.
This symbol indicates that this product must not be disposed together with
household refuses. Deliver product to an collection or recycling center for
electrical or for electronic or electrical equipment.
By ensuring proper disposal of this product, you will help preventing
potential negative impacts to environmental and human health. Otherwise these
effects may be caused by improper waste disposal.
Fault Clearance
Phenomenon’s | Items to be Confirmed | Solutions |
---|---|---|
No water flow out | Whether the water supply system is cut off or the water | |
pressure is too low | Check | |
Whether the water place is blocked and whether the hot water valve is opened |
Check and clean
Flowing cold water| 1. Whether the hot water outlet is not open| Check and
open
2. Whether the water temperature is adjusted property| Calibrate referring to
the use method in the manual
3. The heating time is too short and has not been heated to the setting
temperature| Calibrate according to the use method in the manual
4. Whether the components are damaged| If you have confirmed that the 123
items are not the reason. contact the Maintenance Department
The water cannot be heated to the required temperature or the output amount of
heat water is less| 1. Is the current function mode set correctly or the
temperature set too low| Calibrate a di to the use method in the manual
2. Is the tap water pressure too high| Tum down the flow of the outlet valve
for use
The water is alternately great and less. or alternately cold and hot| Is the
tap water pressure stable| Tum down the flow of the outlet valve for use or
use it after the water pressure is stable
It fails to power on or the display does not work| 1. Whether the power
supply is in good contact| Check the power socket
2. Whether the components are damaged| If you have confined that the 1 item
is not the reason. contact the
Maintenance Department
Display El| Line fault| Contact the Maintenance Department
Display E2/HO| 1. Is the inner tank filled with water| After turning off the
power, fill up water and turn on the power again
2. Whether the components are damaged| If you have confirmed that the 1 item
is not the reason. contact the maintenance department
Display E3//E6/ E8| 1. Whether the indoor temperature is lower than minus
20°C| Cut off the power supply. When the ambient temperature is higher than
minus 19*C. it will return to normal after turn on the power again
2. Whether the sensors are damaged| If you have confined that the 1 item is
not the reason. contact the
Maintenance Department
Product fiche
Trade mark | Haler |
---|---|
Model | ES50V-TF7(EU) |
Load profile | M |
Energy efficiency class | B |
Energy efficiency(%) | 41 |
Annual electricity consumption(kWh) | 1251 |
Thermostat temperature setting(°C) | 75 |
Sound power level indoors(dB) | 15 |
Specific precautions | Refer to the manual |
Daily electricity consumption(kWh) | 7.163 |
V40(L) | 95.4 |
Trade mark | Haler |
---|---|
Model | ES50V-F1(EU) |
Load profile | M |
Energy efficiency class | c |
Energy efficiency(%) | 36 |
Annual electricity consumption(kWh) | 1418 |
Thermostat temperature setting(t) | 75 |
Sound power level indoors(dB) | 15 |
Specific precautions | Refer to the manual |
Daily electricity consumption(kWh) | 6.645 |
V40(L) | 67.4 |
The power consumption data in the table is defined in relation to EU
Directives 812/2013 and 814/2013.
The products without the label and the data sheet for water heaters and solar
devices, stipulated in regulation 812/2013, are not intended to be used in
such assemblies.
This appliance is conforming with the international electrical safety
standards IEC 60335-1 and IEC 60335-2-21. The CE marking of the appliances
attests its conformity to the following EC Directives, of which it satisfies
the essential requisites:
- LVD Low Voltage Directive: EN 60335-1, EN 60335-2-21, EN 60529, EN 62233, EN 50106.
- EMC Electro-Magnetic Compatibility: EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3.
- RoHS2 Risk of Hazardous Substances: EN 50581.
- ErP Energy related Products: EN 50440.
Read User Manual Online (PDF format)