Broan-NuTone ERVS100S Broan Energy Recovery Ventilator Instruction Manual

June 13, 2024
Broan NuTone

Part no. ERVS100SBroan NuTone ERVS100S Broan Energy Recovery
Ventilator NuTone ERVS100S Broan Energy Recovery Ventilator
Instruction Manual

ERVS100S Broan Energy Recovery Ventilator

The Broan ERVS100S is an effective, balanced ventilation solution featuring integrated humidity sensing to limit ventilation during periods of excessive outdoor humidity, thus contributing to a more comfortable indoor environment. This energy recovery ventilator (ERV) provides a supply of fresh, filtered air to the home while exhausting the stale polluted air, thus improving the overall indoor air quality.

  • Compact, low profile platform that can be mounted in a ceiling cavity featuring a pre-painted white access door that can blend into the interior space;
  • Power cord ready design;
  • Integrated humidity sensor limiting the ventilation during periods of excessive outdoor humidity, contributing to a comfortable living indoor environment;
  • Integrates with existing forced-air furnace ducting for easy installation but runs independently to limit energy consumption related to ventilation;
  • Built-in damper on fresh air supply port to prevent outdoor air infiltration when the unit is turned off;
  • Integrated control to easily set the unit at installation with an optional external wall control to boost the unit to high speed.

Product balancing
The ERVS100S is equipped with 2 high static pressure blowers and is factory balanced. Once installed, the ERVS100S will remain balanced (within a 10% total difference between the exhaust and supply airflows) when the static pressure difference between the exhaust and the supply remains below 0.2 in. w.g.
No balancing dampers are required when this condition is met.
Repairs and maintenance
All parts requiring maintenance can be removed in less than 5 minutes allowing easy access for repairs. The PSC motors are permanently lubricated.
Warranty
The BROAN™ ERVS100S is protected by a 5-year warranty on parts only. The energy recovery core is covered by a 5-year warranty, with the original proof of purchase.
Filters
– 2 washable filters, 20 PPI
– MERV 8 optional filters, part V21030.
Defrosting system
Unit performs a negative defrost during 10 minutes every 20 minutes when outdoor temperature is below 14°F, and 10 minutes every 10 minutes below -4°F.
Energy Recovery Core
Material: Polymerized paper
Type: Cross flow
Warranty: 5 years
Accessories

  • Broan VTYIK1 Tandem Termination
  • Broan V14695 Metal Tandem Termination
  • Broan VB20W 20-Minute Override Wall Control

Requirements and standards

  • Complies with UL 1812 standard applicable to ducted Heat Recovery Ventilators;
  • HVI certified;
  • Airflow and energy recovery performance tested in accordance with CSA C439 standard.
Project: Remarks
Location:

Part no.:
Qty.:
Submitted by:                                           Date:

Performance in hot and humid climateBroan NuTone ERVS100S Broan Energy
Recovery Ventilator - climate Performance in hot and dry climateBroan NuTone ERVS100S Broan Energy
Recovery Ventilator - climate 1 Performance in winter seasonBroan NuTone
ERVS100S Broan Energy Recovery Ventilator - climate 2

Specifications

Part number: ERVS100S
Total assembled product weight: 37 lb.
Insulated round ports: 6″ diameter
Built-in magnetic backdraft damper to close outdoor fresh air supply when the unit is turned off
Energy recovery core:
-Type cross flow
-Media membrane: Polymerized paperER
Core filters: 2 washable filters 20 PPI
Optional MERV 8 filter kit, part no. V21030
Housing material: galvanized steel 22 ga
Door and door frame material: White pre-painted steel 20 ga
Insulation material: Molded Expanded polystyrene, UL certified for Energy recovery ventilators requirements
Supply and exhaust blower motors:
-PSC motors
-Protection type: Thermally protected
Installation brackets: included with the unit, allow attic, flush to ceiling and under-ceiling installations. Unit must be installed with the door facing upward or downward. No vertical installation allowed.
Unit electrical characteristics
-Power cord 28″ with 3-prong plug

Volts Frequency  Ampere Watts
120 60 hz 0.9 105

Low voltage connections for optional controls energized by unit

Dimensions

Broan NuTone ERVS100S Broan Energy Recovery Ventilator - climate
3

Safe Installation Zone

This unit is designed for installation where the outdoor temperature is above 14°F throughout the year (zone A on map below). For units installed in zone B, they must be installed in conditioned space or in the ceiling with a surrounding sealed enclosure, see section 3.1.3 of the installation and user guide.Broan NuTone ERVS100S Broan Energy Recovery Ventilator - Installation
Zone Installation (please refer to the installation and user guide for complete details)
Positionning the unit
Installation in the ceiling (option 1 and 2)Broan NuTone ERVS100S Broan
Energy Recovery Ventilator - Installation Zone 1 Refer to Installation and User guide for more details on installation in zone B with a surrounding sealed enclosure.
Installation in attic over the insulation (climate zone A only)Broan
NuTone ERVS100S Broan Energy Recovery Ventilator - Installation Zone
2 Installation under ceiling (in a living area)Broan NuTone ERVS100S Broan Energy Recovery
Ventilator - Installation Zone 3

Combining with an AHU
Recommended configurations
Option 1 – When the distribution of fresh air from the ERV is connected to the return of an AHU (such as in the image below, on the left), static pressure where the fresh air from the ERV enters the AHU return ducting must be below 0.15 in.w.g. to ensure proper functionning of the built-in fresh air damper. If return duct static pressure exceeds the 0.15 in.w.g. threshold, an indirect connection combined with a supplemental return grille or “T” connection with the conditioned space should be used. See the User and Installer guide for more details.Broan NuTone ERVS100S Broan Energy Recovery Ventilator -
Combining Energy performance ERVS100S

Supply
Temperature| Net
Air Flow| Power
Consumed| Sensible
Recovery
Efficiency| Adjusted Sensible
Recovery Efficiency| Latent Recovery/
Moisture Transfer| Total
Recovery
Efficiency| Adjusted Total
Recovery
Efficiency
---|---|---|---|---|---|---|---
| °F| CFM| Watts| 0/0| cyo| cyo| cyo|
Cooling| 95| 64| 46| | | 45| 48| 51
95| 106| 105| | | 35| 38| 41
Heating| 32| 64| 46| 66| 70| 51| |
32| 106| 105| 60| 66| 42| |

NOTE: All specifications are subject to change without notice.

Ventilation performance

Broan NuTone ERVS100S Broan Energy Recovery Ventilator -
performance Note: In high speed, account for an increase in static pressure of proximately 0.2  in. w.g. when installed with the Broan VTYIK1 Tandem transition, depending on installation.

Mode and RH Adjustable Controls Location

Broan NuTone ERVS100S Broan Energy Recovery Ventilator -
Controls Control
Ventilation modes

POSITION MODE DESCRIPTION
SB* Standby Unit is off.

Unit can be activated in high speed by the VB2OW 20-minute push-button control, if applicable
INT| Intermittent| Unit works 20 minutes per hour in low speed.
Unit can be activated in high speed by the VB2OW 20-minute push-button control, if applicable.
1| Low Speed| Unit runs at 65 cfm.
Unit can be activated in high speed by VB2OW 20-minute push-button, if applicable.
2| High Speed| Unit runs at 105 cfm.
Unit can be activated in high speed by the VB2OW 20-minute push-button control, if applicable.

*Factory setting
Relative humidity limit
The ERVS100S monitors the outdoor air conditions (temperature and humidity level) every 10 minutes with a built-in sensor. When the outdoor conditions are above the set limits, the unit will limit the ventilation to 10 minutes per hour and come back to its previous setting when the conditions get back to the set limit. The accepted RH limit varies in function of the outdoor conditions and can be adjusted to 4 different positions:

RH* limit of distributed air

Position| Description| Outdoor temp.
<73°F| Outdoor temp.
≥73°F
OFF| Relative humidity limit is deactivated.| –| –
+| Higher relative humidity limit.| Up to 60%| Up to 80%
N| actory set relative humidity limit.| Up to 55%| Up tp 75%

–| Lower relative humidity limit.| Up to 50%| Up to 70%**

  • The RH limit of distributed air is calculated at 75°F.
    When the outdoor temperature is equal or above 73°F, the maximum relative humidity level accepted is higher considering that the air conditionning will partly dehumidify the incoming fresh air after it is distributed and mixed with the conditionned indoor air.
    Optional controls wiring**

    • Broan VB20W 20-minute push-button control: Activates 105 cfm speed in all ventilation modes (recommended when the unit exhausts from a bathroom).
    • Dry contact standby switch: Unit remains powered on, but is put on Standby mode when the switch is turned on.

Broan NuTone ERVS100S Broan Energy Recovery Ventilator -
OptionalThis connection allows the operation of VB20W push-button controls even if the dry contact standby switch is turned off.

Broan-NuTone LLC, 926 West State Street, Hartford, Wisconsin, USA 53027 Broan-NuTone.com 800-558-1711